• 제목/요약/키워드: electrical system

검색결과 32,543건 처리시간 0.046초

전원부하분석을 통한 무인항공기 전기시스템 설계 및 검증 (Design and Verification of Electrical System for Unmanned Aerial Vehicle through Electrical Load Power Analysis)

  • 우희채
    • 한국군사과학기술학회지
    • /
    • 제21권5호
    • /
    • pp.675-683
    • /
    • 2018
  • In this paper, we have proposed a design and verification methods of electrical system and power loads for unmaned aeriel vehicles(UAVs) through electrical load analysis. In order to meet a UAV system requirement and electrical system specifications, we have designed an electrical power system for efficient power supply and distribution and have theoretically analyzed the power loads according to the power consumption and power bus design of UAV. Using electrical system rig, the designed electrical power system has been experimentally verified. Also, we have performed several flight tests to verify the UAV electrical system and power loads. It is concluded that the proposed design and verification method of electrical system for UAV system.

전기안전 긴급출동제도 운영 실태 분석 (An analysis of the state of operation of the electrical safety emergency dispatch system)

  • 유재근;김재현;이기식;구경완;전정채
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1748-1751
    • /
    • 2012
  • This paper describes the background of the electrical safety emergency dispatch system and analyzes the operational status of the system. This system is to provide the enhanced electrical safety service to general-purpose electrical equipment users. Annual average of about 6 million cases have been implemented since 2005. In order to enhance electrical safety service and more effectively prevent electrical disasters in future, institutional expansion of the electrical safety emergency dispatch system with keeping budget is necessary. If periodic inspections with a remote monitoring system is applied, the effect of electrical safety will be improved.

A CONCEPTUAL DESIGN FOR ELECTRICAL GROUNDING ARCHITECTURE OF KOREAN SPACE LAUNCH VEHICLE

  • Kim Kwang-Soo;Lee Soo-Jin;Ma Keun-Soo;Shin Myoung-Ho;Hwang Seung-Hyun;Ji Ki-Man;Chung Eui-Seung
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.231-234
    • /
    • 2004
  • Electrical grounding is defined as referencing an electrical circuit or a common reference plane for preventing shock hazards and for enhancing operability of the circuit and EMI control. In order to realize the best electrical grounding system of korean space launch vehicle, we should design the electrical grounding architecture of korean space launch vehicle of system-level at the earliest point in design procedure. To minimize the electrical grounding loop and the unnecessary electromagnetic interference or radiation among the electronic subsystems, we should establish the electrical grounding rules of the all electrical interfaces. The electrical interfaces among the electronic subsystems are generally classified into the electrical power and signal interfaces. Because of using the primary and secondary power system architecture in the korean space launch vehicle system such as the common space launch vehicle systems, we need to establish the electrical grounding rules between the primary and secondary power system. We also need to establish the electrical signal grounding interface rules among the electronic subsystems. In this paper, we will describe the grounding schemes of the common space launch vehicle system and propose a conceptual design for the electrical grounding architecture of korean space launch vehicle system.

  • PDF

전기철도시스템의 접지 유형에 따른 귀선 전류 비교 (Comparison of Return current by the Earth type in the Electrical railway system)

  • 이길노;김용규;백종현;유창근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.53-55
    • /
    • 2005
  • In electrical railway system, power supplied to electrical locomotive by catenary is returned to sub-station on track. The current returned to sub-station on track is return current, which is an essential factor for the safety of the wayside electrical equipment and maintenance staff. Therefore, earth system acts an important role to protect wayside electrical equipment and maintenance staff against return current. In general, individual earth system protects partially the electrical railway system, but common earth system does the whole electrical railway system and minimizes the flow of return current. In this paper, we are compared the effect of return current according to earth type by actual measurement in existing electrical railway system. The measurement was conducted at Shinchungju sub~station in high speed trains, and Guro sub-station, which is electrified section in classical line.

  • PDF

전력시스템 고조파 상태 추정에 관한 연구 (Harmonic State Estimation in Power System)

  • 박희철;이정필;왕용필;정형환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.117-120
    • /
    • 2002
  • Electrical power system has very complexity problem that it is plan measurement system to achieve Harmonic State Estimation (HSE). This complexity problem depends on discord of necessary accuracy, certainty of noise that exist in data communication damage and converter, adaptability of network modification and minimum of expense size of system, estimated monitering. Also, quantity of available measurement equipment for harmonic measurement has been limited. Therefore, systematic method that choose measurement location for harmonic state estimation. This paper is that see proposed HSE that use Observability Analysis(OA) for harmonic state estimation of electrical power system. OA depends on measurement number, measurement location and measurement form here, it is analysis method that depend on network form and admittance of the system. OA used achieve harmonic state estimation that it is Applied to New Zealand electrical power system to prove validity of HSE algorithm that propose. This study result about harmonic state estimation of electrical power system displayed very economical and effective method by OA.

  • PDF

PSCAD/EMTDC를 활용한 COMTRADE 기반의 교류철도 급전계통 사고 데이터 분석에 관한 연구 (A Study of Analysis of Fault Data in AC Electrical Railway Power System Based on COMTRADE Using PSCAD/EMTDC)

  • 이지혜;민명환;안태풍;이병곤
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1542-1548
    • /
    • 2018
  • When any faults occurred in electrical railway system, operators need to analysis it quickly and accurately. Existing COMTRADE based analysis tools are not enough to analysis faults occurred in electrical railway system. In this paper, it presents some functions to fault analysis for electrical railway system based on fault data formatted COMTRADE. These functions are implemented in PSCAD/EMTDC and it can be shown that analyzed results against actual electrical fault cases which were occurred in the electrical railway power system.

환경영향 요소를 고려한 특고압 전기설비의 안전등급 평가시스템 (Assessment System of Safety Level of High Voltage Electrical Facilities Considering Environmental Factors)

  • 김동우;임용배;이기연;문현욱
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.249-254
    • /
    • 2017
  • This paper presents an assessment system of safety level of 22.9kV grade high voltage electrical facilities considering environmental factors. The assessment system was developed based on the following procedure. Firstly, assessment structure was determined by consulting standards regarding inspection and diagnosis of electrical facilities. Secondly, contents of items and sub items of assessment system were developed. Thirdly, in order to quantify the importance of the assessment system, the weight was calculated using Analytic Hierarchy Process(AHP). Lastly, assessment table of safety level was developed including environmental factors such as period of use and load factor. The developed system can evaluate the safety level of high voltage facilities in an objective way. Therefore it can be applicable to electrical safety management system based on Internet of Things(IoT).

가상현실 기반 체험형 전기안전 교육 시스템의 개발 및 효과 분석 (Development and Effect Analysis of Experiential Electrical Safety Education System Based on Virtual Reality)

  • 전정채
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1767-1773
    • /
    • 2016
  • Every year, lives are lost due to electrical safety accidents that could have been prevented with proper education and awareness of electrical safety. To prevent such accidents, experiential education is more effective than indoctrination education. This paper describes the electrical safety education system based on virtual reality (VR) and evaluates effect of the proposed system. Users operated the experiential electrical safety education system, and they were provided electrical stimulation in an electric shock experience using a haptic device. Appropriate stimulation values were calculated according to age (children vs. adults) and gender through experiment. The scenario in which participants experience electrical safety in the home environment was structured, and related educational contents was produced. A total of 68 healthy elementary students evaluated the educational effect of the system. The results showed that the educational effect and the sustainability of effect of the proposed system are superior to those of existing multimedia learning methods. By implementing electrical safety education stimulating the senses of human, the learning effect was promoted and this experiential education would be able to prevent electrical accidents.

수용가 전기설비 사고처리 시스템 및 케이블 사고사례 연구 (The Study of Cable Fault Case and the Fault Management System of Electrical Facilities for private use)

  • 김영석;송길목;김선구
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.59-62
    • /
    • 2009
  • When happen the electrical facilities accident the one's diagnosis system of fault cause was constructed by FMEA method Cable accident cause is given by accident cause that can happen in each one's diagnosis and accident probability value. From the verification of system, the one's diagnosis system agreed well with result that analyzed actual state. Thus, the system is judged to be used effectively examine for accident cause of electrical facilities.

  • PDF

The Best Line Choice for Transmission System Expansion Planning on the Side of the Highest Reliability Level

  • Sungrok Kang;Trungtinh Tran;Park, Jaeseok;Junmin Cha;Park, Daeseok;Roy Billinton
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권2호
    • /
    • pp.84-90
    • /
    • 2004
  • This paper presents a new method for choosing the best line for transmission system expansion planning considering the highest reliability level of the transmission system. Conventional methodologies for transmission system expansion planning have been mainly focused on economics, which is the minimization of construction costs. However, quantitative evaluation of transmission system reliability is important because successful operation and planning of an electric power system under the deregulated electricity market depends on transmission system reliability management. Therefore, it is expected that the development of methodology for choosing the best lines considering the highest transmission system reliability level while taking into account uncertainties of transmission system equipment is useful for the future. The characteristics and effectiveness of the proposed methodology are illustrated by the case study using a MRBTS.