• 제목/요약/키워드: electrical strength

검색결과 2,267건 처리시간 0.03초

Implementing a Dielectric Recovery Strength Measuring System for Molded Case Circuit Breakers

  • Cho, Young-Maan;Rhee, Jae-ho;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1752-1758
    • /
    • 2018
  • In a low-voltage distribution system, the molded case circuit breaker (MCCB) is a widely used device to protect loads by interrupting over-current; however the hot gas generated from the arc discharge in the interrupting process depletes the dielectric recovery strength between electrodes and leads to re-ignition after current-zero. Even though the circuit breaker is ordinarily tripped and successfully interrupts the over-current, the re-ignition causes the over-current to flow to the load again, which carries over the failure interruption. Therefore, it is necessary to understand the dielectric recovery process and the dielectric recovery voltage of the MCCB. To determine these characteristics, a measuring system comprised of the experimental circuit and source is implemented to apply controllable recovery voltage and over-current. By changing the controllable recovery voltage, in this work, re-ignition is driven repeatedly to obtain the dielectric recovery voltage V-t curve, which is used to analyze the dielectric recovery strength of the MCCB. A measuring system and an evaluation technique for the dielectric recovery strength of the MCCB are described. By using this system and method, the measurement to find out the dielectric recovery characteristics after current-zero for ready-made products is done and it is confirmed that which internal structure of the MCCB affects the dielectric recovery characteristics.

Electrical Breakdown Strength of Insulation under Combined DC-AC Voltages

  • Grzybowski, S.
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제11권10호
    • /
    • pp.32-39
    • /
    • 1998
  • Electrical breakdown strength of paper-oil and polypropylene/film-oil insulation samples was measured under dc, ac and pulsating voltages. The latter was obtained by superimposing ac upon dc volate and provides an attractive method for a simultaneous testing and assessment of the state of insulation of the various parts of HV apparatus in service. The measurements were carried out over a wide range of the pulsation ratio defined as p=Eac/Edc. The results obtained under pulsating voltages follow colsely an experssion which relates the breakdown strength to the sum of arc tangent and arc cotangent function of the parameter p. The study was carried out using dry paper as well as paper containing various degrees of moisture. The presence of moisture showed a pronounced effect upon the breakdown strength which varied with the pulsation parameter p.

  • PDF

PET 필름의 전기적 특성에 미치는 계면효과 (The Effects of Interfacial on the Electrical Properties in PET Films)

  • 강무성;이창훈;박수길;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권5호
    • /
    • pp.281-284
    • /
    • 1999
  • In this paper, the electrical conduction, breakdown strength and dielectric properties were investigated in the interfaces of PET films. The volume resistivity and breakdown strength were decreased; especially the specimens with semiconductive layer showed the lowest breakdown strength. This decrease of electrical properties was appeared by increasing charge density in inhomogeneous layer of PET. The dielectric properties of PET did not show significant difference with PET/PET but the films with semiconductive interface layer showed the increase in capacitance and $tan\delta$ was affected by the PET rather than semiconductive layer. It is assumed that the variation of $tan\delta$ was affected by the dielectric polarization and the leakage current(charge).

  • PDF

Effect of Silica Particle Size on the Mechanical Properties in an Epoxy/Silica Composite for HV Insulation

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권5호
    • /
    • pp.248-251
    • /
    • 2012
  • In order to develop a high voltage insulation material, epoxy/micro-silica composites (EMC) and epoxy/micro-silica/nano-silica composites (EMNC) with three different particle sizes in ${\mu}m$ and one particle size in nm were prepared and their tensile and flexural tests were carried out and the data was estimated by Weibull statistical analysis. The tensile strength of the neat epoxy was 82.8 MPa and those of the EMCs were larger than that of the neat epoxy, and they were much more advanced by the addition of 10 nm sized nano-silica to the EMCs. Flexural strength showed the same tendency of the tensile strength. As the micro-particle size decreased, tensile and flexural strength increased.

CYCLOALIPHATIC 애폭시 복합재료의 가속열화에 미치는 전기적 및 기계적 특성에 관한 연구 (A Study on The Electrical and Mechanical Characteristics due to accelerated degradation of Cycloaliphatic Epoxy Composites)

  • 김희곤;조한구;박용관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1323-1326
    • /
    • 1994
  • the application of epoxy composite materials for outdoor insulating systems has some significant advantages compared with conventional inorganic materials, that is low weight in combination with high mechanical strength, small dimensions and design versatility. The experimental results for the basis composition and interlace characteristics of the matrix resin/inorganic fillers($SiO_2$) which are the composite materials have been studied. The electrical characteristics(electrical breakdown, dielectric, insulating resistivity, tracking) and mechanical characteristics( tensile strength, elongation, flexible strength) in the epoxy composite materials have been studied. The life of the epoxy composite material was evaluated by accelerated Weather-Ometer test and the degradation process due to outdoor exposure condition is discussed with respect to the mechanical and electrical properties.

  • PDF

A Study on the Electrical Strength of Insulating Materials for High-Tc Superconducting Devices

  • Bae, Duck Kweon;Kim, Chung-Hyeok;Pak, Min-Sun;Oh, Yong-Cheul;Kim, Jin-Sa;Shin, Cheol-Gee;Lee, Joon-Ung;Song, Min-Jong;Choi, Woon-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권6호
    • /
    • pp.294-300
    • /
    • 2005
  • According to the trend for electric power equipment of high capacity and reduction of its size, the needs for the new high performance electric equipments become more and more important. On of the possible solution is high temperature superconducting (HTS) power application. Following the successful development of practical HTS wires, there have been renewed activities in developing superconducting power equipment. HTS equipments have to be operated in a coolant such as liquid nitrogen ($LN_2$) or cooled by conduction-cooling method such as using Gifford-McMahon (G-M) cryocooler to maintain the temperature below critical level. In this paper, the dielectric strength of some insulating materials, such as unfilled epoxy, filled epoxy, and polyimide in $LN_2$ was analyzed. Epoxy is a good insulating material but fragile at cryogenic temperature. The filled epoxy composite not only compensates for this fragile property but enhances its dielectric strength.

기계적 응력상태에서 절연지 및 케이블의 전기절연 특성 (The Characteristics of Electrical Breakdown of Dielectric Paper and Cable under mechanical stress)

  • 김영석;곽동순;김해종;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 영호남 학술대회 논문집
    • /
    • pp.3-6
    • /
    • 2003
  • The electrical and mechanical properties of dielectric paper and cable at cryogenic temperature have been investigated to optimum insulating design of high-Tc superconducting(HTS) cable. From the results, Tensile strength of PPLP in liquid nitrogen was high more than that of air, but tensile strain could know that decrease sharply. According as tensile strength increases, the breakdown stress of PPLP in liquid nitrogen was decreased because PPLP was degradated. According as bending radius multiple is decrese, breakdown voltage decreased sharply. And bending radius multiple is thought that more than about 25 is suitable.

  • PDF

고온 초전도 케이블 절연을 위한 절연지의 인장응력 및 절연파괴 특성 (The Characteristics of Electrical Breakdown and Tensile Stress of Dielectric Paper for Insulation of HTS Cable)

  • 김영석;곽동순;김해종;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 초전도 자성체 연구회
    • /
    • pp.61-64
    • /
    • 2003
  • The degradation of the dielectric properties of insulating papers that were used under loaded conditions at cryogenic temperature was paid attention. Electrical and tensile stress properties of dielectric paper at cryogenic temperature have been investigated to optimum insulating design of high-Tc superconducting(HTS) cable. Tensile strength of PPLP in liquid nitrogen was high more than that of air, but tensile strain could know that decrease sharply. According as tensile strength increases, the breakdown stress of PPLP in liquid nitrogen was decreased.

  • PDF

나노탄소물질을 함유하는 알루미늄기지 복합소재 개발 (Development of Aluminum Matrix Composites Containing Nano-carbon Materials)

  • 김정준;김대영;최현주
    • 한국분말재료학회지
    • /
    • 제28권3호
    • /
    • pp.253-258
    • /
    • 2021
  • There is increasing demand for the development of a new material with high strength, high stiffness, and good electrical conductivity that can be used for high-voltage direct current cables. In this study, we develop aluminum-based composites containing C60 fullerenes, carbon nanotubes, or graphene using a powder metallurgical route and evaluate their strength, stiffness, coefficient of thermal expansion, and electrical conductivity. By optimizing the process conditions, a material with a tensile strength of 800 MPa, an elastic modulus of 90 GPa, and an electrical conductivity of 40% IACS is obtained, which may replace iron-core cables. Furthermore, by designing the type and volume fraction of the reinforcement, a material with a tensile strength of 380 MPa, elastic modulus of 80 GPa, and electrical conductivity of 54% IACS is obtained, which may compete with AA 6201 aluminum alloys for use in all-aluminum conductor cables.

Effects of Rehabilitation Exercise Combined with Electrical Muscle Stimulation on Pain, Muscle Strength, and Function in Soldiers Undergoing Knee Meniscectomy

  • Yong-Jun Yu;Won-Seob Shin
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권2호
    • /
    • pp.140-148
    • /
    • 2023
  • Objective: Meniscal injuries are a common and high-risk condition among military personnel, leading to difficulties in performing missions.The objective of this study is to investigate the effects of combining electrical muscle stimulation therapy with exercise therapy during rehabilitation on pain, muscle strength, and function in patients after meniscectomy. Design: A two-group pretest-posttest design Methods: A total of 30 subjects were included in this study. They were randomly assigned to either the experimental group (n=15), which received knee extensor strengthening exercise along with electrical muscle stimulation, or the control group (n=15), which received only knee extensor strengthening exercise. Pre-test was conducted prior to the intervention, which consisted of 30 minutes of treatment five times a week for a total of 20 sessions. Post-test was performed after a 4-week period. Pain, strength, and function were assessed before and after the intervention. Results: The results of the study showed that there was a significant difference in pain reduction and muscle strength improvement in the experimental group, and a significant difference was also found between the experimental group and the control group in terms of functional evaluation. Conclusions: The combination of exercise therapy and electrical muscle stimulation therapy resulted in greater improvements in pain, strength, and function assessment, contributing to improved overall function.