• Title/Summary/Keyword: electrical stimulator

Search Result 79, Processing Time 0.022 seconds

Analysis and Design of Whole-Head Magnetic Brain Stimulators: A Simulation Study

  • Lee, Chany;Im, Chang-Hwan;Jung, Hyun-Kyo
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.3
    • /
    • pp.337-342
    • /
    • 2007
  • This paper proposes a helmet-type whole-head brain stimulator system considering a realistic head geometry. For more accurate design and computer simulations, a realistic volume conductor model was adopted and the current evoked on human cerebral cortex was analyzed using the boundary element method (BEM). To obtain a more focalized evoked current around the target points, various coil configurations were tested and an average targeting error of about 10 mm was obtained.

The Development of Virtual Reality Therapy(VRT) System for the Treatment of Acrophobia (고소공포증의 치료를 위한 가상 현실 시뮬레이터의 제작)

  • Paek, Seung-Eun;Ryu, Jong-Hyun;Beack, Seung-Hwa
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.10
    • /
    • pp.486-493
    • /
    • 2001
  • Acrophobia is an abnormal fear of heights. Medications or cognitive-behavior methods have been mainly used as a treatment. Lately the virtual reality technology has been applied to that kind of anxiety disorders. A virtual environment provides patient with stimuli which arouses phobia, and exposing to that environment makes him having ability to over come the fear. In this study, the elevator stimulator that composed with a position sensor, head mount display, and audio system, is suggested. To illustrate the physiological difference between a person who has a feel of phobia and without phobia, heart rate was measured during experiment. And also measured a person's HR after the virtual reality training and in a real building elevator. In this study, we demonstrated the subjective effectiveness of virtual reality psychotherapy through the clinical experiment.

  • PDF

Development of surface electrode type electrical stimulator or supporting walk function in foot drop patients (족하수 환자에서의 보행기능 보조를 위한 표피 자극형 전기자극기 개발)

  • Lim, S.K.;Jeong, H.C.;Kim, K.G.;Jin, D.B.;Park, B.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.9-13
    • /
    • 1997
  • The present study was designed to develop the functional electrical stimulation system in order to restore motor function of paralytic patients. We attempt to establish adequate stimulus parameters for the recovery of work unction in lower limb paralysis patients and to develop the electrical stimulation system, which is effective to protect foot drop in these patients. In our animal and human experiment, adequate stimulus condition for surface electrode on the lower limb were 0.2-0.3ms at the duration and 50 Hz, which contain 600Hz train pulse. This parameter has efficiently prevented the foot drop from lower limb paralysis, decreased muscle fatigue and induced powerful contraction of lower limb muscle.

  • PDF

The Effects of Low-Frequency Electrical Stimulation on Abdominal Core Muscle Activity and Thickness (저주파 전기자극이 복부 중심근육 활성도 및 두께에 미치는 영향)

  • Lee, H.J.;Lee, J.Y.;Tae, K.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • Core muscle is the most crucial for rehabilitation of patients with musculoskeletal and nervous problem, there is pain, imbalance and functional movement disorder of upper and lower extremities. In this study, low-frequency electrical stimulator was developed for the purpose increasing the activity of rectus abdominis (RA) and the thickness of transverse abdominis (TrA), internal obliquus abdominis (IO), and external obliquus abdominis (EO). Fifteen female in their 20's was divided into a experiment groups (traditional electrical stimulation group, developed electrical stimulation group) and control group. Low-frequency electrical stimulation was performed in experimental groups for 4 times a week, 4 weeks. The muscle activities (RA) by EMG and muscle thickness (TrA, IO, EO) by Ultrasonogrphy imaging were measured, respectively. In the result, the muscle activity of RA and muscle thickness of TrA and EO were significantly increased at developed electrical stimulation group (p<.05). Therefore, the developed low-frequency electrical stimulation is useful for rehabilitation with CNS and PNS subjects.

  • PDF

A Study on Design of FES Hardware System for Walking of Paraplegics (하반신마비 환자의 보행기능 제어를 위한 FES하드웨어 시스템 설계에 관한 연구)

  • 김근섭;김종원
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 1991
  • This paper describes and discusses the employment of HMG pattern analysis to provide upper-motor-neuron paraplegics with patient-responsive control of FES ( functional electrical stimulation) for the purpose of walker-supported walking. The use of above-lesion EMG signals as a solution to the control problem is considered. The AR(autoregressive)parameters are identified by time-varying nonstationary Kalman filler algorithm using DSP chip and classified by fuzzy theory. The control and stimuli part of the below-lesion are based on micro-processor(8031). The designed stimulator is a 4-channel version. The experiments described above have only attempted to discriminate between standing function and sit-down function A further advantge of the this system Is applied for motor rehabilitation of social readaption of paralyzed humans.

  • PDF

The development of the WEB-Based Virtual Reality for the Treatment of the Alcoholism (알코올중독자 치료를 위한 WEB 기반 가상현실 제작)

  • Paek, Seung-Eun;Beack, Seung-Hwa;Ryu, Jong-Hyun;Kim, Dong-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2690-2692
    • /
    • 2004
  • Medications or cognitive-behavior methods have been mainly used as a treatment of alcoholism. lately the virtualy technology has been applied to the kink of alcoholic disorders. A virtual environment makes him having ability to over come the drink. In this study, we were implemented by making panorama images and 3D object modules using 3D Studio MAX. VRML, JAVA Applet. And the BAR stimulator that composed with a position sensor head mount display, and audio system, is suggested. To illustrate the physiological difference between a person who has a alcoholism and and without a liquor bottle, heart rate was measured during experiment, and also measured a Person's HR after the virtual reality training. we demonstrated the subjective effectiveness of virtual reality psychotherapy through the clinical experiment.

  • PDF

R & D of Smartwear Built-In TENS Device for Relief of Dysmenorrhea (생리통 완화를 위한 저주파 치료기(TENS) 내장 스마트 의복 개발 연구)

  • Lee, Won-Joon;Um, So-Hee
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.2
    • /
    • pp.320-329
    • /
    • 2009
  • This research attempts to develop a method to relieve dysmenorrhea, which is an obstacle to many women's social activities, by designing a smartwear with built-in thermotherapy and TENS device. TENS therapy has the advantages of being controlled by patients and not depending on the use of drugs. The TENS device is designed as a stomach band so as to be unnoticeable to others when outer clothes are worn; the size was minimized and attached to underwear to facilitate use everywhere at any time. A current problem is the limitation of minimizing, but as battery technology is further developed, we can anticipate much smaller devices. The development of aforementioned smartwear function will increase women's choices in occupations and general improvement in quality of life.

  • PDF

Development of Isolated Arbitrary Waveform Generator Based on Microprocessor (마이크로프로세서를 이용한 분리형 임의파형발생기의 개발)

  • Kim, Nam-Hyun;Kim, Won-Ky;Yoo, Sun-Kook;Yang, Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.53-58
    • /
    • 1989
  • An arbitrary waveform generator was developed for the experiment of electro-physiology and the electrical stimulator. This system has been constructed three parts. (1 ) Data input parts (2) Data processing and control parts (3) Analog signal output parts The system characteristics were as follows. (1) System based on Microprocessor (2) Input using Thumbwheel switch (3) Isolated output signal (4) System flexibility

  • PDF

Thermal Stimulation System for Meridian point (경혈 열자극 시스템)

  • Yang, S.Y.;Huh, W.;Kim, J.K.;Park, Y.B.
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.223-226
    • /
    • 2001
  • In this paper, we devised electrical thermal stimulator for meridian point. The system consist of has four channel applicator, power controller and computer. The applicator consist of resistance wire heater and thermal sensor. A stimulation patterns are obtained from a real moxa combustion. The developed system does not make any smog, does not need moxa anymore, only need electricity.

  • PDF

An electric pulp tester using a constant current source (정 전류원 이용한 치수(齒髓) 검사기)

  • Kim, J.S.;Nam, K.C.;Kim, S.C.;Lee, S.J.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.720-723
    • /
    • 2003
  • Electric stimulation of teeth is used for assessing pulp vitality. Because of very high and wide range of impedance of the enamel, electric pulp testers use high voltage, high output impedance and alternative current source. Most pulp testers use voltage stimulation method and their stimulating threshold levels significantly depend on each individual. Therefore, a constant current stimulator is necessary to minimize the effect of wide variation in enamel thickness. In this study, we constructed a constant current source type of pulp tester with the maximum current of 150 uA.

  • PDF