• Title/Summary/Keyword: electrical resistivity method

검색결과 839건 처리시간 0.026초

SiC-$ZrB_2$계(係) 복합체(複合體)의 전기전도기구(電氣傳導機溝) (Electrical Conduction Mechanism of SiC-$ZrB_2$ Composites)

  • 주진영;권주성;신용덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1336-1338
    • /
    • 1997
  • Relations between the composites of SiC-$ZrB_2$ electro-conductive ceramic composites and their electrical resistivity, as well as their temperature, were investigated. The electrical resistivity of hot-pressed composites was measured by the Pauw method in the temperature of RT to $100^{\circ}C$. The electrical resistivity of the composites follow the electrical conduction model for a homogenous mixture of two kinds of particles with different conductivity. Also the electrical resistivity versus temperature curves indicate the formation of local chains of $ZrB_2$ particles. In the case of SiC-$ZrB_2$ composites containing above 30Vol.% $ZrB_2$ showed PTCR, whereas the electrical resistivity of SiC-15Vol.% $ZrB_2$ showed NTCR.

  • PDF

Single-configuration FPP method에 의한 실리콘 웨이퍼의 비저항 정밀측정 (Precision Measurement of Silicon Wafer Resistivity Using Single-Configuration Four-Point Probe Method)

  • 강전홍;유광민;구경완;한상옥
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1434-1437
    • /
    • 2011
  • Precision measurement of silicon wafer resistivity has been using single-configuration Four-Point Probe(FPP) method. This FPP method have to applying sample size, shape and thickness correction factor for a probe pin spacing to precision measurement of silicon wafer. The deference for resistivity measurement values applied correction factor and not applied correction factor was about 1.0 % deviation. The sample size, shape and thickness correction factor for a probe pin spacing have an effects on precision measurement for resistivity of silicon wafer.

전기비저항을 이용한 지반오염누출감지시스템 개발 (Subsurface Contaminant Leak Detection System using Electrical Resistivity Measurement)

  • 박준범;오명학;이주형
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 지반환경 및 준설매립에관한 학술세미나
    • /
    • pp.42-71
    • /
    • 2001
  • Leakage detection system can possibly locate leak point without laboratory analysis. Several different types of sensors provide these benefits. But the use of these technologies is not widespread, mainly because of cost. Each of the leakage detection systems available has different advantages and disadvantages. The ideal system would be affordable, durable enough to last through the life of the landfill, automated, and applicable to all types of landfills. The laboratory tests were performed to investigate the relationship between electrical resistivity and the unsaturated subsurface condition and to evaluate the contamination due to leachate based on measuring electrical resistivity. The results of experiment show that the electrical resistivity of soil decreases as moisture density increases. The electrical resistivity of soil decreases as the concentration of leachate in pore fluid increases. These facts indicate that electrical resistivity method can be a promising tool in detecting of leachate. Also, the field model tests were conducted to verify that detection of leachate leak point on detection system using electrical characteristics is accurate. Field model test results of leakage detection system imply that the leakage detection system using electrical characteristics have the great potential of detecting exactly the leak point of leachate.

  • PDF

전기비저항탐사결과와 터널막장 암반분류의 상관성 검토 (A study on the correlation between the result of electrical resistivity survey and the rock mass classification values determined by the tunnel face mapping)

  • 최재화;조철현;류동우;김학규;서백수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.265-272
    • /
    • 2003
  • In this study, the rock mass classification results from the face mapping and the resistivity inversion data are compared and analyzed for the reliability investigation of the determination of the rock support type based on the surface electrical survey. To get the quantitative correlation, rock engineering indices such as RCR(rock condition rating), N(Rock mass number), Q-system based on RMR(rock mass rating) are calculated. Kriging method as a post processing technique for global optimization is used to improve its resolution. The result of correlation analysis shows that the geological condition estimated from 2D electrical resistivity survey is coincident globally with the trend of rock type except for a few local areas. The correlation between the results of 3D electrical resistivity survey and the rock mass classification turns out to be very high. It can be concluded that 3D electrical resistivity survey is powerful to set up the reliable rock support type.

  • PDF

역전과 알고리즘(BP)을 이용한 대지저항률 추청 방법에 관한 연구 (A Study on Methodology of Soil Resistivity Estimation Using the BP)

  • 류보혁;위원석;김정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권2호
    • /
    • pp.76-82
    • /
    • 2002
  • This paper presents the method of sail-resistivity estimation using the backpropagation(BP) neural network. Existing estimation programs are expensive, and their estimation methods need complex techniques and take much time. Also, those programs have not become well spreaded in Korea yet. Soil resistivity estimation method using BP algorithm has studied for the reason mentioned above. This paper suggests the method which differs from expensive program or graphic technology requiring many input stages, complicated calculation and professional knowledge. The equivalent earth resistivity can be presented immediately after inputting apparent resistivity through the personal computer with a simplified Program without many Processing stages. This program has the advantages of reasonable accuracy, rapid processing time and confident of anti users.

$\beta$-SiC+39vol.%$ZrB_2$ 복합체의 전기저항률 (Electrical Resistivity of the $\beta$-SiC+39vol.%$ZrB_2$ Composites)

  • 신용덕;주진영;윤세원;황철;이종덕;송준태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1916-1918
    • /
    • 1999
  • The electrical conductive mechanism and temperature dependence of electrical resistivity of ${\beta}-SiC+ZrB_2$ composites with $Al_2O_3+Y_2O_3$ contents were investigated. The electrical resistivity of hot-pressed composites was measured by the Pauw method from $25^{\circ}C$ to $700^{\circ}C$. The electrical resistivity of the composites showed the PTCR(Positive Temperature Coefficient Resistivity) and follow the electrical conduction model for a homogeneous mixture of two kind of particles with different conductivity. Also, the electrical resistivity versus temperature curves indicate the formation of local chains of $ZrB_2$ particles.

  • PDF

옥천대(沃川帶)의 지질(地質) 및 광물자원(鑛物資原)에 관(關)한 연구(硏究) -봉화재 지역(地域)에 대(對)한 전기비저항탐사(電氣比抵抗探査)- (Electrical Resistivity Survey on the Geolgical Structure of the Bonghwajae Area in the Okchon Zone)

  • 민경덕;김창렬;윤춘성;정승환
    • 자원환경지질
    • /
    • 제21권2호
    • /
    • pp.131-137
    • /
    • 1988
  • Geological and electrical resistivity surveys were carried out to investigate subsurface geology and geologic structure of the Bonghwajae area in the Okchon zone. Pseudosections of the apparent electrical resistivity distribution along the three survey lines were obtained by using dipole-dipole electrode array method, and models of subsurface geology and geologic structure by using two dimensional finite difference method. The Bonghwajae fault zone exists around Bonghwajae area in the north-south direction, and is a boundary between Okchon Group and Choson Supper Group. Metabasite and hornblende gabbro intruded along the Bonghwajae fault zone remaining two fracture zones with low resistivity value of 20 ohm-m and widths of about 100m and 70-300m. They strike nearly N-S and dip westward with a high angle of $60-70^{\circ}$. Sochangri fault with a width of about 160m exists between Jisogori and Bonghwajae, by which Bonghwajae fault zone is displaced about 1km in the east-west direction. Hornblende gabbro whose electrical resistivity value is in the range of 5000-8000 ohm-m intruded the metabasite of 2000-4500 ohm-m after the Sochangri fault had formed. Great Limestone Group is widely distributed in the east of Bonghwajae fault zone, and interbeds so called Yongam formation of graphitic black slate with an extremely low electrical resistivity value of 2 ohm-m.

  • PDF

선택적 증착에 의해서 제작한 ZnO 박막의 전기저항률 특성 (The Characteristic on Electrical Resistivity of Zno film by Ramped method)

  • 이우선;최권우;조준호;박진성;서용진;김상용;정용호;이진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 반도체재료
    • /
    • pp.26-29
    • /
    • 2001
  • ZnO thin film had been deposited on the glass by Evaporation Ramped method. and electrical and resistivity were investigated. Evaporation gas($O_{2}$,) pressure was 10mTorr~100mTorr, chamber pressure was $2{\times}10^{-5}$, and then ZnO film were deposited. AI-doped ZnO thin film had the lowest resistivity ($1{\times}10^{4}\;{\Omega}{\cdot}cm$), and then carrier concentration and Hall mobility were$6.27{\times}10^{20}\;cm^{3}$ and $22.04 cm^{2}/V{\cdot}s$, respectively. When ZnO film had been deposited by Ramp6ed method compared with normal method and investigated resistivity.

  • PDF

3전극과 4전극 전위강하법으로 측정한 대지저항률의 비교 (Comparison of the Earth Resistivity Measured by the 3-Electrode and 4-Electrode Fall-of-Potential Methods)

  • 이복희;김기복
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.95-101
    • /
    • 2013
  • This paper presents the comparison of the earth resistivity obtained from the measurements made with the three-electrode and four-electrode fall-of-potential techniques. The ${\rho}-a$ curve obtained from Wenner four-electrode method in undisturbed earth is in good agreement with the ${\rho}-l$ curve obtained from the three-electrode method based on the fall-of- potential method. However, The ${\rho}-a$ curve in disturbed earth with moisture and freezing is significantly different with the ${\rho}-l$ curve. The ${\rho}-a$ curve is considerably sensitive to the freezing and the moisture present in the earth surface compared to the ${\rho}-l$ curve. Thus to determine the actual earth resistivity, it is necessary to take into account the earth surface conditions when measuring the earth resistivity.

대지저항률의 주파수 의존성 (Frequency relativity of soil resistivity)

  • 이복희;조성철;엄주홍
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.373-376
    • /
    • 2003
  • A new method measuring soil resistivity in frequency range of 5-500[KHz] using variable frequency inverter was presented, and soil resistivity was analysed by resistive and reactive components on the basis of magnitude and phase of measured ground impedance. The test lead arrangement was proposed to reduce the inductive coupling in test circuit for measuring the soil resistivity. The frequency dependence of soil resistivity was mainly caused by the inductive current flowing through grounding conductors over the frequency of 70[KHz].

  • PDF