• Title/Summary/Keyword: electrical power apparatus

Search Result 322, Processing Time 0.027 seconds

On-Line Monitoring of Power Apparatus with Infrared Thermography (적외선 열화상을 이용한 수전설비 온라인 감시)

  • Lim, Young-Bae;Jeong, Seung-Cheon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.441-444
    • /
    • 2004
  • Each electrical apparatus radiates various infrared as the condition of surface and load current. Because heat distribution of the apparatus changes as the condition, it is able to analyze the condition of the apparatus by using the distribution. However, methods having been used to measure the heat distribution cannot compare normal condition with abnormal, and the apparatus has diagnosed by intuition. This paper deal with a program that is able to analyze changed temperature distribution. The program is to analyze temperatures on pixels in selected region of interest or position and is able momently and logically to analyze condition of the apparatus. The results are able to apply to a on-line monitoring system.

  • PDF

Investigation of the Supercritical Fluids as an Insulating Medium for High Speed Switching

  • Shon, Chae-Hwa;Song, Ki-Dong;Oh, Yeon-Ho;Oh, Ho-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1783-1786
    • /
    • 2016
  • The paper investigates the insulation properties of the supercritical $CO_2$ ($SCCO_2$) fluid as an insulating medium for electrical apparatuses. The insulating material is crucial for electrical apparatuses and $SF_6$ gas has been widely used for high power electrical apparatuses. There have been many research efforts to develop substituents for $SF_6$ gas because of high global warming potential. We obtained above 350 kV/mm insulation strength with 12.0 MPa $SCCO_2$. The positive and negative IEC standard pulses are applied between two 10 mm diameter spherical electrodes. The insulation strength of $SCCO_2$ is at least 2.5 times higher than that of $CO_2$ gas at 6.0MPa. The insulation strength of $SCCO_2$ fluid is about 10 times higher than that of $SF_6$ at 0.5MPa which is the ordinary operating pressure of electrical switchgears. Using the result, we expect that the time for switching and dielectric recovery could be reduced using $SCCO_2$ fluid as an insulating medium.

System Loss Improvement through Proper Location of Active and Reactive Power Apparatus (유무효전력설비의 적소투입을 통한 전력손실개선)

  • 이상중
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.77-80
    • /
    • 2000
  • This paper presents a method for improving the power loss through optimal location of active or reactive power apparatus. The paper introduces the los sensitivities which imply the variation of the power loss with respect to the incremental bus power P, Q and uses them as the investment information for the active and reactive power apparatus. Power apparatus are invested, by the priority of loss sensitivities indices given for each bus.

  • PDF

Optimization Design for Dynamic Characters of Electromagnetic Apparatus Based on Niche Sorting Multi-objective Particle Swarm Algorithm

  • Xu, Le;You, Jiaxin;Yu, Haidan;Liang, Huimin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.660-665
    • /
    • 2016
  • The electromagnetic apparatus plays an important role in high power electrical systems. It is of great importance to provide an effective approach for the optimization of the high power electromagnetic apparatus. However, premature convergence and few Pareto solution set of the optimization for electromagnetic apparatus always happen. This paper proposed a modified multi-objective particle swarm optimization algorithm based on the niche sorting strategy. Applying to the modified algorithm, this paper guarantee the better Pareto optimal front with an enhanced distribution. Aiming at shortcomings in the closing bounce and slow breaking velocity of electromagnetic apparatus, the multi-objective optimization model was established on the basis of the traditional optimization. Besides, by means of the improved multi-objective particle swarm optimization algorithm, this paper processed the model and obtained a series of optimized parameters (decision variables). Compared with other different classical algorithms, the modified algorithm has a satisfactory performance in the multi-objective optimization problems in the electromagnetic apparatus.

Effect on the Transport Current and Quench Resistance of the HTS Wire with Normal-Superconducting Junction During the Fault Current Applying (사고전류 인가 시 초전도선재의 상전도-초전도 접합부가 통전전류와 ?치저항에 미치는 영향)

  • Hong, Gong-Hyun;Du, Ho-Ik;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.10
    • /
    • pp.625-629
    • /
    • 2015
  • The second-generation HTS wire its YBCO coated conductor is widely used in the superconducting power apparatus. The YBCO coated conductor uses the normal-superconducting junction to increase the transport capacity of superconducting power apparatus when it is applied. The normal-superconducting junction can be a cause of reducing the stability of the superconducting power apparatus when a fault current is applied. Thus, in this study we have conducted the effect analysing normal-superconducting junction for the fault current using transport current and quench resistance. From the experimental results when a fault current is applied, the effect on the normal-superconducting junction is reduced the larger the amplitude of the fault current and is helpful to maintain the thermal stability of the HTS wire.

Design and Analysis of an Axial Flux Magnet for Magnetic Levitation System. (자기부상용 증축형 전자석의 설계 및 특성 해석)

  • Kang, Do-Hyun;Shin, Pan-Seok;Kim, Yong-Joo;Cho, Yun-Hyun;Park, Do-Young
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.63-67
    • /
    • 1990
  • An axial flux magnet for a magnetic levitation system is designed and analysed by finite element simulations. The results are compared with those of experiment in order to verify the analysing method. Lift force, air gap flux density and temperature characteristics of the magnet showed fairly good agreement with each other.

  • PDF

The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System (적외선 열화상 카메라를 이용한 수전설비 온도분포해석)

  • Jeong, Seung-Cheon;Lim, Yeung-Bae;Kim, Jong-Seo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF

Development of Optical Transmission System for The Diagnosis of Power Apparatus Using Laser Beam (레이저를 이용한 전력설비 진단용 광전송 시스템 개발)

  • Hong, J.Y.;Cho, K.L.;Lee, J.H.;Chang, Y.M.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.275-277
    • /
    • 1993
  • It is practically required to develop an optical transmission system, for the diagnosis of electric power apparatus, which enables to distinguish the right signals related to the partial discharge taken place inside the apparatus. These partial discharges are transformed into ultra sonic signals by the sensor and then used for the voltage application to pokels cell. Afterwards, the modulated laser beam is transmitted through the optical fiber. Throughout this work, a laser-beam based detecting system is developed and permits us to reproduce the transmitted signals indirectly without electromagnetic interference. For this purpose the characteristics of this system is well analyzed by means of different type of signals from function generator.

  • PDF

Characteristics of Optical Power of Low Level Laser Apparatus (저출력 레이저 치료기의 광 출력 특성)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Kim, Yong-Pil;Yu, Seong-Mi;Park, No-Bong;Lee, Hee-Gab
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.496-496
    • /
    • 2007
  • Low level laser has various therapy effects. This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 660nm Laser diode for blood stream improvement and was designed for a pulse width modulation type to increase stimulation effects. In result, we could get the light power of 660nm wavelength and the 1~10Hz irradiation frequency could be controlled stably.

  • PDF