• 제목/요약/키워드: electrical power

검색결과 26,919건 처리시간 0.039초

Design of a Series Voltage Sag Compensation System in Transmission Line

  • Park, Hyen-Young;Kim, Yang-Mo;Lee, Gyo-Sung;Oh, Se-Ho;Park, Jung-Gyun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제2B권4호
    • /
    • pp.191-200
    • /
    • 2002
  • When power consumption increases, power supply must be efficient and reliable for good power quality. The studies on compensation system of power quality are processing actively. Voltage sag among of factors for power quality is generally PI dual control that voltage sag compensation is used. But this control is no more available since of 120[KHz] ripple rejection. So we proposed the control algorithm using PID control in 3-phase unbalanced power system and the series voltage compensator, when voltage sag occurs.

전기부하설비의 전력분석을 위한 데이터 획득 시스템의 개발 (Development of Data Aquisition System for Electrical Power Analysis of Electrical Load equipments)

  • 이상익;전정채;유대근
    • 조명전기설비학회논문지
    • /
    • 제18권1호
    • /
    • pp.60-66
    • /
    • 2004
  • 전기부하설비의 전압, 전류, 전력, 고조파 등의 분석을 위해서는 수학적 모델링 보다는 실제 계측을 통한 전력분석이 필요하고 이를 통해 전기설비의 효율적인 관리, 에너지 절약 및 사고 예방에 필요한 대책을 수립할 수 있다. 특히 비선형 부하에 의해 발생되는 고조파의 대책수립을 위해 계측을 통한 전력분석이 필수적이다. 따라서 본 논문에서는 전기부하설비에 공급되는 전력을 측정하고 분석할 수 있는 저가형 데이터 획득 시스템을 DSP 기반으로 개발하였고 이를 실제 전력계통에 설치하여 전력 및 고조파의 측정과 분석을 수행함으로써 그 성능을 입증하였다.

Power Quality Warning of High-Speed Rail Based on Multi-Features Similarity

  • Bai, Jingjing;Gu, Wei;Yuan, Xiaodong;Li, Qun;Chen, Bing;Wang, Xuchong
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.92-101
    • /
    • 2015
  • As one type of power quality (PQ) disturbance sources, high-speed rail (HSR) can have major impacts on the power supply grid. Providing timely and accurate warning information for PQ problems of HSR is important for the safe and stable operation of traction power supply systems and the power supply grid. This study proposes a novel warning approach to identify PQ problems and provide warning prompts based on the monitored data of HSR. To embody the displacement and status change of monitored data, multi-features of different sliding windows are computed. To reflect the relative importance degree of these features in the overall evaluation, an analytic hierarchy process (AHP) is used to analyse the weights of multi-features. Finally, a multi-features similarity algorithm is applied to analyse the difference between monitored data and the reference data of HSR, and PQ warning results based on dynamic thresholds can be analysed to quantify its severity. Cases studies demonstrate that the proposed approach is effective and feasible, and it has now been applied to an actual PQ monitoring platform.

건설현장의 수전설비 및 배.분전반의 현장실태 분석 (The Analysis of Field Condition for Power Receiving System and Patch and Panel Boards at Construction Sites)

  • 길형준;한운기;김향곤;최충석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.335-340
    • /
    • 2004
  • To analyze risk factors of temporary power installations, the investigation was carried out for power receiving system and pack and panel boards at construction sites. The subject was variable such as an airport, an apartment, a municipal playground. There are many risk factors caused by inadequate working environments and the deterioration of temporary power installations using equipment with minimum safety devices at construction sites. There, it is intended to present problems and preventive measures against electrical shock accidents, through analyzing risk factors of real field condition and investigating temporary power installations all over the country.

  • PDF

단상 배전 STATCOM을 이용한 전기철도시스템의 전압강하 및 전력품질 향상 (Compensation of voltage drop and improvement of power quality at AC railroad system with single-phase distributed STATCOM)

  • 김준상;김진오;이준경;정현수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.192-193
    • /
    • 2006
  • An AC electrical railroad system has rapidly changing dynamic single-phase load, and at a feeding substation, three-phase electric power is transformed to the paired directional single-phase electric power. There is a great difference in electrical phenomenon between the load of AC electrical railroad system and that of general power system. Electric characteristics of AC electrical railroad's trainload are changed continuously according to the traction, operating characteristic, operating schedule, track slope, etc. Because of the long feeding distance of the dynamic trainload, power quality problems such as voltage drop, voltage imbalance and harmonic distortion may also occur to AC electrical railroad system. These problems affect not only power system stability. but also power quality deterioration in AC electrical railroad system. The dynamic simulation model of AC electrical railroad system presented by PSCAD/EMTDC is modeled in this paper, and then, it is analyzed voltage drop and power quality for AC electrical railroad system both with single-Phase distributed STATCOM(Static Synchronous Compensator) installed at SP(Sectioning Post) and without.

  • PDF

Power Flow Control of a Multi-bus/Three-feeder Distribution System Using Generalized Unified Power Quality Conditioner

  • Mohammed, B.S.;Ibrahim, R.;Perumal, N.;Rao, K.S. Rama
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.8-17
    • /
    • 2015
  • This paper analyses the power flow of a three-feeder/multi-bus distribution system by a custom Generalized Power Quality Conditioner (GUPQC). The GUPQC has been realized by three voltage source converters (VSCs) coupled back-to-back through a common DC-link capacitor on the DC-side. One feeder was controlled by the shunt compensator, whereas each of the other two feeders was controlled by the proposed novel series compensator. The GUPQC has the capability to simultaneously compensate voltage and current quality problems of a multi-bus/three-feeder distribution system. Besides that, the power can be transferred from one feeder to other feeders to compensate for poor power quality problems. Extensive simulation studies were carried out by using MATLAB/SIMULINK software to establish the ability of the GUPQC to improve power quality of the distribution systems under distorted supply voltage conditions.

A Thermal Model for Electrothermal Simulation of Power Modules

  • Meng, Jinlei;Wen, Xuhui;Zhong, Yulin;Qiu, Zhijie
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권4호
    • /
    • pp.441-446
    • /
    • 2013
  • A thermal model of power modules based on the physical dimension and thermal properties is proposed in this paper. The heat path in the power module is considered as a one-dimensional heat transfer in the model. The method of the parameters extraction for the model is given in the paper. With high speed and accuracy, the thermal model is suit for electrothermal simulation. The proposed model is verified by experimental results.

제한된 전원을 사용하는 저전력 시스템 설계 (Design of the low-power system using the limited source)

  • 김도훈;이교성;김용상;박종철;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.163-165
    • /
    • 2003
  • Over the past several years, the application extent of the real-time systems is being expanded with the progress of civilization. An effort to minimize power consumption at the system is being accomplished in several fields from the design of an analog/digital circuit up to the device level Things of this effort have included the power optimum-technique to minimize power consumption at the digital logic circuit and the dynamic managed skill by means o( the decision of the operating system. In this paper, we designed of low power system by using Power-optimized method. As an effective low-power design, we designed the low power system which it has a monitoring system within the main board and a personal computer.

  • PDF

A Novel Algorithm for Fault Type Fast Diagnosis in Overhead Transmission Lines Using Hidden Markov Models

  • Jannati, M.;Jazebi, S.;Vahidi, B.;Hosseinian, S.H.
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.742-749
    • /
    • 2011
  • Power transmission lines are one of the most important components of electric power system. Failures in the operation of power transmission lines can result in serious power system problems. Hence, fault diagnosis (transient or permanent) in power transmission lines is very important to ensure the reliable operation of the power system. A hidden Markov model (HMM), a powerful pattern recognizer, classifies events in a probabilistic manner based on fault signal waveform and characteristics. This paper presents application of HMM to classify faults in overhead power transmission lines. The algorithm uses voltage samples of one-fourth cycle from the inception of the fault. The simulation performed in EMTPWorks and MATLAB environments validates the fast response of the classifier, which provides fast and accurate protection scheme for power transmission lines.

Study of Optimal Location and Compensation Rate of Thyristor-Controlled Series Capacitor Considering Multi-objective Function

  • Shin, Hee-Sang;Cho, Sung-Min;Kim, Jin-Su;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.428-435
    • /
    • 2013
  • Flexible AC Transmission System (FACTS) application study on enhancing the flexibility of AC power system has continued to make progress. A thyristor-controlled series capacitor (TCSC) is a useful FACTS device that can control the power flow by adjusting line impedances and minimize the loss of power flow and voltage drop in a transmission system by adjusting line impedances. Reduced power flow loss leads to increased loadability, low system loss, and improved stability of the power system. This study proposes the optimal location and compensation rate method for TCSCs, by considering both the power system loss and voltage drop of transmission systems. The proposed method applies a multi-objective function consisting of a minimizing function for power flow loss and voltage drop. The effectiveness of the proposed method is demonstrated using IEEE 14- and a 30-bus system.