• Title/Summary/Keyword: electrical injury

Search Result 170, Processing Time 0.031 seconds

Toe Tissue Transfer for Reconstruction of Damaged Digits due to Electrical Burns

  • Kim, Hyung-Do;Hwang, So-Min;Lim, Kwang-Ryeol;Jung, Yong-Hui;Ahn, Sung-Min;Song, Jennifer K.
    • Archives of Plastic Surgery
    • /
    • v.39 no.2
    • /
    • pp.138-142
    • /
    • 2012
  • Background : Electrical burns are one of the most devastating types of injuries, and can be characterized by the conduction of electric current through the deeper soft tissue such as vessels, nerves, muscles, and bones. For that reason, the extent of an electric burn is very frequently underestimated on initial impression. Methods : From July 1999 to June 2006, we performed 15 cases of toe tissue transfer for the reconstruction of finger defects caused by electrical burns. We performed preoperative range of motion exercise, early excision, and coverage of the digital defect with toe tissue transfer. Results : We obtained satisfactory results in both functional and aesthetic aspects in all 15 cases without specific complications. Static two-point discrimination results in the transferred toe cases ranged from 8 to 11 mm, with an average of 9.5 mm. The mean range of motion of the transferred toe was $20^{\circ}$ to $36^{\circ}$ in the distal interphalangeal joint, $16^{\circ}$ to $45^{\circ}$ in the proximal interphalangeal joint, and $15^{\circ}$ to $35^{\circ}$ in the metacarpophalangeal joint. All of the patients were relatively satisfied with the function and appearance of their new digits. Conclusions : The strategic management of electrical injury to the hands can be both challenging and complex. Because the optimal surgical method is free tissue transfer, maintenance of vascular integrity among various physiological changes works as a determining factor for the postoperative outcome following the reconstruction.

Susceptibility Weighted Imaging of the Cervical Spinal Cord with Compensation of Respiratory-Induced Artifact

  • Lee, Hongpyo;Nam, Yoonho;Gho, Sung-Min;Han, Dongyeob;Kim, Eung Yeop;Lee, Sheen-Woo;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.209-217
    • /
    • 2018
  • Purpose: The objective of this study was to obtain improved susceptibility weighted images (SWI) of the cervical spinal cord using respiratory-induced artifact compensation. Materials and Methods: The artifact from $B_0$ fluctuations by respiration could be compensated using a double navigator echo approach. The two navigators were inserted in an SWI sequence before and after the image readouts. The $B_0$ fluctuation was measured by each navigator echoes, and the inverse of the fluctuation was applied to eliminate the artifact from fluctuation. The degree of compensation was quantified using a quality index (QI) term for compensated imaging using each navigator. Also, the effect of compensation was analyzed according to the position of the spinal cord using QI values. Results: Compensation using navigator echo gave the improved visualization of SWI in cervical spinal cord compared to non-compensated images. Before compensation, images were influenced by artificial noise from motion in both the superior (QI = 0.031) and inferior (QI = 0.043) regions. In most parts of the superior regions, the second navigator resulted in better quality (QI = 0.024, P < 0.01) compared to the first navigator, but in the inferior regions the first navigator showed better quality (QI = 0.033, P < 0.01) after correction. Conclusion: Motion compensation using a double navigator method can increase the improvement of the SWI in the cervical spinal cord. The proposed method makes SWI a useful tool for the diagnosis of spinal cord injury by reducing respiratory-induced artifact.

Change of Pain Threshold and Nociceptive Flexion Reflex of Hyperalgesia Rat by High Voltage Pulsed Current (고전압맥동전류가 통각과민 백서의 통각역치 및 유해성 굴곡반사에 미치는 영향)

  • Kim, Su-Hyon;Moon, Dal-Ju;Choi, Sug-Ju;Jung, Dae-In;Lee, Jung-Woo;Jeong, Jin-Gyu;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.2
    • /
    • pp.25-34
    • /
    • 2006
  • Purpose: This study conducted quantitative sensory test and nociceptive flexion reflex(NFR) measurement to examine degree of pain depending on polarity of high voltage pulsed current(HVPC) of hyperalgesia site in hyperalgesia rat by local thermal injury. mechanical pain threshold, thermal pain threshold and root mean square of NFR were measured. Methods: This study was conducted with control group I of hyperalgesia rat at hind paw by thermal injury and experimental groups divided into cathodal HVPC group II, anodal HVPC group III and alternate HVPC group IV. It measured pain threshold and root mean square(RMS) of NFR and obtained the following results. Results: Mechanical pain threshold of hyperalgeisa site was significantly increased at groups II, III and IV applying HVPC group compared to control group, but there was no difference among HVPC groups. Thermal pain threshold of hyperalgesia site showed a significant increase in group II. Group III showed significant difference after 4 days of hyperalgesia. RMS of NFR at hyperalgeisa site was significantly reduced in group II after 2 days of hyperalgesia. Group III showed significant decrease after 5 and 6 days of hyperalgesia. Conclusion: Consequently it was found that application of HVPC of hyperalgesia site increased pain threshold at hyperalgesia site by mechanical stimuli and thermal stimuli. NFR by electrical stimuli was similar to pain threshold by mechanical stimuli. Effects by polarity of HVPC showed the greatest reduction of hyperalgesia when cathodal electrode was used.

  • PDF

Identifications of Reflex Muscle Activities and Joint Moments Triggered by Electrical Stimulation to Sole of the Foot during Lokomat Treadmill Walking

  • Kim, Yong-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.344-350
    • /
    • 2010
  • The aim of this study was to investigate the characteristics of the flexion withdrawal reflex modulated during Lokomat treadmill walking in people with spinal cord injury. The influence of the limb position and movement were tested in 5 subjects with chronic spinal cord injury. EMG activities from tibialis anterior and moments of the hip joint elicited by the foot stimulation were examined during Lokomat treadmill walking. To trigger the flexion withdrawal reflex during Lokomat treadmill walking, a train of 10 stimulus pulses was applied at the skin of the medial arch. The TA EMG activity was modulated during gait phase and the largest TA reflex was obtained after heel-off and initial swing phase. During swing phase, TA EMG was 40.9% greater for the extended hip position (phase 6), compared with flexed hip position (phase 8). The measured reflex moment of the hip joint was also modulated during gait phase. In order to characterize the neural contribution of flexion reflex at the hip joint, we compared estimated moments consisted of the static and dynamic components with measured moment of the hip joint. The mean static gains of reflex hip moments for swing and stance phase are -0.1, -0.8, respectively. The mean dynamic gains of reflex hip moments are 0.25 for swing, 0.75 for stance phase. From this study, we postulate that the joint moment and muscle response of flexion withdrawal reflex have the phase-dependent modulation and linear relationship with hip angle and angular velocity for swing phase during Lokomat treadmill walking.

Accidental ingestion of E-cigarette liquid nicotine in a 15-month-old child: an infant mortality case of nicotine intoxication

  • Seo, An Deok;Kim, Dong Chan;Yu, Hee Joon;Kang, Min Jae
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.12
    • /
    • pp.490-493
    • /
    • 2016
  • Electronic cigarettes are novel tobacco products that are frequently used these days. The cartridge contains liquid nicotine and accidental poisoning, even with a small oral dose, endangers children. We present here a mortality case of a 15-month-old child who ingested liquid nicotine mistaking it for cold medicine. When the emergency medical technicians arrived, she was found to have pulseless electrical activity. Spontaneous circulation was restored after approximately 40 minutes of cardiopulmonary resuscitation. The cotinine level in her urine was 1,716 ng/mL. Despite intensive supportive care, severe anoxic brain injury was found on computed tomography and the child ultimately died. This fatality highlights the need for public health efforts to minimize such accidents.

Advanced Automatic Reclosing in Power Distribution Systems (배전시스템에서의 개선된 재폐로방식)

  • Rim, Seong-Jeong;Oh, Jung-Hwan;Yun, Sang-Yun;Kim, Jae-Chul;Choi, Byoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.242-244
    • /
    • 1997
  • This paper presents an advanced automat ic reclosing scheme in power distribution system to minimize the impact of electric facilities and the customers' damage. This scheme can determines the number of reclosing attempts to reduce the influence of electric equipment and injury of customers' load using a magnitude of fault current and types. To verify the effectiveness of the proposed scheme, numerical simulation is carried out with field data. Results demonstrate that the proposed scheme can minimizes the impact of electric facility and customers' damage than exist ing scheme.

  • PDF

The Study development of body balance function rehabilitation training equipment (인체평형기능 재활훈련장치의 개발에 관한 연구)

  • O, J.Y.;Kim, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.422-425
    • /
    • 2002
  • Position balance control refers to ability that is kept bodily center of gravity under minimum position shake on surface of land. Patients who an injury of brain, a wound of the central nervous system or weakening of leg muscular power is fallen are trend increasing steadily by the car accident body balance function is on an increasing trended. These patients have difficulty in position balance control, receive big restriction walk and life style. This research composed to do body balance function rehabilitation training which elevate leg muscular power using step machine. And expect to become effective rehabilitation training device because measuring bodily pressure center using Force Platform and do so that can confirm training result easily as that is monitor.

  • PDF

A Study on the design of functional electrical stimulation system for hemiplegic patients (편마비환자를 위한 휴대용 자극시스템 설계에 관한 연구)

  • Kim, N.H.;Park, J.K.;Kwon, J.W.;Jang, Y.K.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.99-102
    • /
    • 1996
  • The ultimate object of FES is on the recovering function of body and shape demaged from desease or injury to original state. On this study, object is recovering of gait function of the disabled who, especially, have gait disturbance. Paralyzed muscle from the central nerve disable, if peripheral nerves which be in the lower part of the harmed are activated, muscle contraction is possible. The traumatic trouble, peripheral nerves aren't connected to a central nerve but origin of peripheral nerve cells which are in the lower part of the harmed are alive, react on stimulation. We design 4-channel stimulator, being based on standard stimuli pattern. stimulator is manufactured with compact size and light weight to portable.

  • PDF

Neuropathic cancer pain: prevalence, pathophysiology, and management

  • Yoon, So Young;Oh, Jeeyoung
    • The Korean journal of internal medicine
    • /
    • v.33 no.6
    • /
    • pp.1058-1069
    • /
    • 2018
  • Neuropathic cancer pain (NCP) is caused by nerve damage attributable to the cancer per se, and/or treatments including chemotherapy, radiotherapy, and surgery; the prevalence is reported to be as high as 40%. The etiologies of NCP include direct nerve invasion or nerve compression by the cancer, neural toxicity, chemotherapy, and radiotherapy. NCP is subdivided into plexopathy, radiculopathy, and peripheral neuropathies, among several other categories. The clinical characteristics of NCP differ from those of nociceptive pain in terms of both the hypersensitivity symptoms (burning, tingling, and an electrical sensation) and the hyposensitivity symptoms (numbness and muscle weakness). Recovery requires several months to years, even after recovery from injury. Management is complex; NCP does not usually respond to opioids, although treatments may feature both opioids and adjuvant drugs including antidepressants, anticonvulsants, and anti-arrhythmic agents, all of which improve the quality-of-life. This review addresses the pathophysiology, clinical characteristics and management of NCP, and factors rendering pain control difficult.

Safety Principles in the Application of Lasers in Energy-based Aesthetic Procedures from the Nurse's Perspective

  • Kim, Youn Jeong
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.34-38
    • /
    • 2020
  • Recently, various lasers and energy-based devices (EBDs) have been widely used in aesthetic procedures. Although using lasers and energy-based aesthetic procedures presents a potential risk to doctors, nurses, and patients, aesthetic procedures tend to be performed without the necessary precautions. For injury prevention, it is essential to follow safety rules and be aware of potential accidents. Furthermore, it is important to understand the basic principles of the devices, including the different optical and electrical properties. Acquiring the exact knowledge to control a device is important for two reasons; to maintain a safer operating environment and prolong the lifespan of expensive devices. This review briefly summarizes the knowledge needed for better and safer aesthetic procedures and the proper control of aesthetic devices.