• 제목/요약/키워드: electrical impedance

검색결과 2,485건 처리시간 0.029초

A Coupled-Line Type Waveguide Bandpass Filter using Normalized Impedance Concept

  • Park, Jun-Seok;Kim, Young-Tae;Kim, Sun-Hyeong;Lim, Jae-Bong;Cho, Hong-Goo
    • Journal of electromagnetic engineering and science
    • /
    • 제3권2호
    • /
    • pp.126-132
    • /
    • 2003
  • In this paper, a coupled-line type waveguide bandpass filter is newly proposed. The proposed bandpass filter configuration consists of magnetically coupled waveguide cavities. In order to show the background of the proposed waveguide bandpass filter, the general coupled line TEM bandpass filter theory, which means the coupled line filter with arbitrary coupled line length and impedance level, will be briefly introduced. Calculations for the even- and odd-mode wave impedance of a coupled line waveguide structure are achieved based on the normalized impedance concept for a broad-side coupled waveguides by using vector finite element method(VFEM) calculation. Measured result of an implemented coupled-line type waveguide filter is presented.

PQ변동을 이용한 개선된 계통 임피던스 추정기법 (An Improved Grid Impedance Estimation using PQ Variations)

  • 조제희;김용욱;김래영
    • 전력전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.152-159
    • /
    • 2015
  • In a weak grid condition, the precise grid impedance estimation is essential to guaranteeing the high performance current control and power transfer for a grid-connected inverter. This study proposes a precise estimation method for grid impedance by PQ variations by employing the variation method of reference currents. The operation principle of grid impedance estimation is fully presented, and the negative impact of the phase locked loop is analyzed. Estimation error by a synchronization angle in the park's transformation using the phase locked loop is derived. As a result, the variation method of reference currents for accurate estimation is introduced. The validation of the proposed method is verified through several simulation results and experiments based on a 2-kW voltage source inverter prototype.

고조파 상태 공간 출력임피던스에 기반한 DC-DC 부스트 컨버터의 안정도 해석 (Stability Analysis of DC-DC Boost Converters Based on Output Impedance in HSS)

  • 헤리얀토누르;박범수;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2020년도 전력전자학술대회
    • /
    • pp.455-456
    • /
    • 2020
  • This paper proposes stability evaluation of DC/DC boost converters based on output impedance in harmonic transfer function matrix considering line impedance and cascaded voltage and current control loops. The harmonic state-space (HSS) model of converter and controller is developed to obtain the harmonic transfer function matrix of closed-loop output impedance. This work is useful for impedance-based stability analysis of converters connected to DC power systems.

  • PDF

지중송전선로의 대칭분 임피던스 모델링에 관한 연구 (A Study on the Sequence Impedance Modeling of Underground Transmission Systems)

  • 황영록;김경철
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.60-67
    • /
    • 2014
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. The majority of fault in transmission lines is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and ground wires in overhead transmission systems and through cable sheaths and earth in underground transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, EMTP-based sequence impedance calculation method was described and applied to 345kV cable transmission systems. Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.

방사선 피폭선량에 대한 생체 조직의 임피던스 변화 (Impedance Changes of Living Tissue During Radiation Exposure Dose)

  • 길상형;이무석;남지호;이영화;김군도;이종규
    • Journal of Radiation Protection and Research
    • /
    • 제38권4호
    • /
    • pp.202-207
    • /
    • 2013
  • 생체 조직의 전기 신호는 살아 있는 조직과 관련된 많은 정보를 포함하고 있으며, 생체 조직에 생물학적 변화가 있으면 고유의 전기적 특성이 변화한다. Impedance/Gain-phase analyzer로 1 KHz에서 1 KHz까지 주파수 대역을 설정한 다음 교류 주파수를 인가하며 돼지안심 조직의 임피던스 특성을 방사선 피폭선량에 따라 변화가 있는지 알아보고자 하였다. 임피던스 크기는 주파수에 비례하여 감소하였으며, 상관계수(r)가 -0.96으로 높은 음의 상관관계를 보였다. 위상차 변화는 거의 없었으며 조직은 저항성을 나타내었다. 측정값은 변동계수가 ${\pm}5$%이내로 재현성이 있음을 알 수 있었고, 측정 시간 경과에 따른 임피던스 크기와 위상차 변화는 유의적인 차이가 없었다.(p>0.05) 방사선 피폭 시 임피던스 변화는 대조군과 비교했을 때 1 Gy, 2 Gy, 4 Gy 피폭 선량에서는 임피던스 크기는 감소하였으나, 유의적인 차이는 없었다.(p>0.05) 그러나 10 Gy 피폭 선량에서는 임피던스 크기 감소가 유의적으로 나타났다.(p<0.05) 방사선 피폭선량이 증가하여도 위상차 변화는 거의 없었으며, 대조군과 비교했을 때 1 Gy, 2 Gy, 4 Gy, 10 Gy 모두 유의적인 차이가 없었다.(p>0.05) 본 연구를 통해 생체 조직의 전기적 특성을 이해 할 수 있었고, 방사선 피폭선량에 따른 임피던스 변화를 측정하여 방사선이 인체에 미치는 영향을 직접 평가 할 수 있는 가능성을 확인 할 수 있었다.

Modified Transmission Line Protection Scheme in the Presence of SCC

  • Naeini, Ehsan Mostaghimi;Vaseghi, Behrouz;Mahdavian, Mehdi
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.533-540
    • /
    • 2017
  • Distance relay identifies the type and location of fault by measuring the transmission line impedance. However any other factors that cause miss calculating the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of the important factors which directly changes the measured impedance by the relay is series capacitive compensation (SCC). Another factor that changes the calculated impedance by distance relay is fault resistance. This paper provides a method based on the combination of distance and differential protection. At first, faulty transmission line is detected according to the current data of buses. After that the fault location is calculated using the proposed algorithm on the transmission line. This algorithm is based on active power calculation of the buses. Fault resistance is calculated from the active powers and its effect will be deducted from calculated impedance by the algorithm. This method measures the voltage across SCC by phasor measurement units (PMUs) and transmits them to the relay location via communication channels. The transmitted signals are utilized to modify the voltage signal which is measured by the relay. Different operating modes of SCC and as well as different faults such as phase-to-phase and phase-to-ground faults are examined by simulations.

Development of an Intelligent Charger with a Battery Diagnosis Function Using Online Impedance Spectroscopy

  • Nguyen, Thanh-Tuan;Doan, Van-Tuan;Lee, Geun-Hong;Kim, Hyung-Won;Choi, Woojin;Kim, Dae-Wook
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1981-1989
    • /
    • 2016
  • Battery diagnosis is vital to battery-based applications because it ensures system reliability by avoiding battery failure. This paper presents a novel intelligent battery charger with an online diagnosis function to circumvent interruptions in system operation. The charger operates in normal charging and diagnosing modes. The diagnosis function is performed with the impedance spectroscopy technique, which is achieved by injecting a sinusoidal voltage excitation signal to the battery terminals without the need for additional hardware. The impedance spectrum of the battery is calculated based on voltage excitation and current response with the aid of an embedded digital lock in amplifier in a digital signal processor. The measured impedance data are utilized in the application of the complex nonlinear least squares method to extract the battery parameters of the equivalent circuit. These parameters are then compared with the reference values to reach a diagnosis. A prototype of the proposed charger is applied to four valve-regulated lead-acid batteries to measure AC impedance. The results are discussed.

전위간섭을 기초로 한 병렬 접지봉의 합성접지임피던스의 분석 (An Analysis on Resultant Ground Impedance Based on the Potential Interference Of Parallel Ground Rods)

  • 이복희;성창훈;양순만
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.107-112
    • /
    • 2011
  • Multiple ground rods are commonly used to obtain the low ground impedance, but they will not reduce the ground impedance unless the spacings between the ground rods are sufficient. This paper presents the experimental results of frequency-dependent resultant ground impedance of two ground rods in parallel. The resultant ground impedance of two ground rods in parallel were measured as functions of the spacing and length of ground rods and the frequency of test currents and were discussed based on the potential interferences. As a consequence, the frequency-dependent ground impedance of single ground rod and two combined ground rods give capacitive. It was found that the effect of potential interference on the ground impedance is directly associated with the frequency-dependent ground impedance and is strong in low frequency. Also, in order to reduce the increasing rate of resultant ground impedance of two ground rods due to potential interference to within 10(%), two ground rods in parallel will be placed over one rod length apart.

자기단 전원 임피던스 추정 기법을 사용한 병행 2회선 송전선로 고장점 표정 알고리즘 (A Fault Location Algorithm Using Adaptively Estimated Local Source Impedance for a Double-Circuit Transmission Line System)

  • 박건호;강상희;김석일;신종한
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.373-379
    • /
    • 2012
  • This paper presents a fault location algorithm based on the adaptively estimated value of the local sequence source impedance for faults on a parallel transmission line. This algorithm uses only the local voltage and current signals of a faulted circuit. The remote current signals and the zero-sequence current of the healthy adjacent circuit are calculated by using the current distribution factors together with the local terminal currents of the faulted circuit. The current distribution factors consist of local equivalent source impedance and the others such as fault distance, line impedance and remote equivalent source impedance. It means that the values of the current distribution factors can change according to the operation condition of a power system. Consequently, the accuracy of the fault location algorithm is affected by the two values of equivalent source impedances, one is local source impedance and the other is remote source impedance. Nevertheless, only the local equivalent impedance can be estimated in this paper. A series of test results using EMTP simulation data show the effectiveness of the proposed algorithm. The proposed algorithm is valid for a double-circuit transmission line system where the equivalent source impedance changes continuously.

충방전 온도에 따른 $LiM_{y}Mn_{2-y}O_{4}$정극 활물질의 임피던스 특성 분석 (The AC impedance of $LiM_{y}Mn_{2-y}O_{4}$cathode material by charge and discharge temperature)

  • 정인성;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.351-354
    • /
    • 2000
  • AC impedance of LiM $n_2$ $O_4$ and LiM $g_{0.1}$M $n_{1.9}$ $O_4$ samples have been studied at various temperature with charge-discharge test. AC impedance of LiM $n_2$ $O_4$ measured at -2$0^{\circ}C$, room temperature and 5$0^{\circ}C$ revealed that initial impedance before charge-discharge test was gradually decreased and become small by becoming law temperature. It indicates that the Li ion diffusion and the transfer resistance of the cathode are related to the temperature of cycling. Impedance at high temperature was suddenly increased because Mn dissolution and decomposition of electrolyte had been increased during cycling, compared to impedance at low temperature. Therefore, charge-discharge capacity was suddenly decreased at high but was slowly at low. In LiM $g_{0.1}$M $n_{1.9}$ $O_4$, impedance and capacity were stability at room temperature than there at 5$0^{\circ}C$, too. Initial impedance at 5$0^{\circ}C$ before charge-discharge test was small and impedance was suddenly increased during cycling than that at room temperature.ure.ure.

  • PDF