• Title/Summary/Keyword: electrical detector

Search Result 913, Processing Time 0.026 seconds

Study on Electrical Properties of X-ray Sensor Based on CsI:Na-Selenium Film

  • Park Ji-Koon;Kang Sang-Sik;Lee Dong-Gil;Choi Jang-Yong;Kim Jae-Hyung;Nam Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.3
    • /
    • pp.10-14
    • /
    • 2003
  • In this paper, we have introduced the x-ray detector built with a CsI:Na scintillation layer deposited on amorphous selenium. To determine the thickness of the CsI:Na layer, we have estimated the transmission spectra and the absorption of continuous x-rays in diagnostic range by using computer simulation (MCNP 4C). A x-ray detector with 65 ${\mu}m$-CsI:Na/30 ${\mu}m$-Se layer has been fabricated by a thermal evaporation technique. SEM and PL measurements have been performed. The dark current and x-ray sensitivity of the fabricated detector has been compared with that of the conventional a-Se detector with 100 ${\mu}m$ thickness. Experimental results show that both detectors exhibit a similar dark current, which was of a low value below $400 pA/cm^2$ at 10 V/${\mu}m$. However, the CsI:Na-Se detector indicates high x-ray sensitivity, roughly 1.3 times that of a conventional a-Se detector. Furthermore, a CsI:Na-Se detector with an aluminium reflective layer shows a 1.8 times higher x-ray sensitivity than an a-Se detector. The hybrid type detector proposed in this work exhibits a low dark current and high x-ray sensitivity, and, in particular, excellent linearity to the x-ray exposure dose.

Facial Point Classifier using Convolution Neural Network and Cascade Facial Point Detector (컨볼루셔널 신경망과 케스케이드 안면 특징점 검출기를 이용한 얼굴의 특징점 분류)

  • Yu, Je-Hun;Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.3
    • /
    • pp.241-246
    • /
    • 2016
  • Nowadays many people have an interest in facial expression and the behavior of people. These are human-robot interaction (HRI) researchers utilize digital image processing, pattern recognition and machine learning for their studies. Facial feature point detector algorithms are very important for face recognition, gaze tracking, expression, and emotion recognition. In this paper, a cascade facial feature point detector is used for finding facial feature points such as the eyes, nose and mouth. However, the detector has difficulty extracting the feature points from several images, because images have different conditions such as size, color, brightness, etc. Therefore, in this paper, we propose an algorithm using a modified cascade facial feature point detector using a convolutional neural network. The structure of the convolution neural network is based on LeNet-5 of Yann LeCun. For input data of the convolutional neural network, outputs from a cascade facial feature point detector that have color and gray images were used. The images were resized to $32{\times}32$. In addition, the gray images were made into the YUV format. The gray and color images are the basis for the convolution neural network. Then, we classified about 1,200 testing images that show subjects. This research found that the proposed method is more accurate than a cascade facial feature point detector, because the algorithm provides modified results from the cascade facial feature point detector.

Monte-Carlo Simulation on Properties of X-ray Detector with Multi-layer Structure (몬테카를로 시뮬레이션을 통한 다층 구조 엑스선 검출기의 특성 평가)

  • Shin, Jung-Wook;Park, Ji-Koon;Seok, Dea-Woo;Lee, Chae-Hoon;Kim, Jea-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.427-430
    • /
    • 2003
  • The properties of digital X-ray detectors depend on the absorption extent of X-rays, the generated signal of each X-ray photon and the distribution of the generated signal between pixels. In digital X-ray detector with single layer, signal is generated by X-ray photon captured in photoconductor. In X-ray detector with multi structure that scintillator formed above the top of photoconductor, signal is generated both by X-ray photon captured each in scintillator and photoconductor. X-ray detector with multi structure is generated more signal than single layer detector. In this paper, we simulated absorption fraction of X-ray detector with multi-layer using Monte Carlo program. The results compared with single-layer detector to be formed scinillator or photoconductor.

  • PDF

A Study on the Design of the Phase Detector with Variable Input Frequency (가변적인 입력 주파수를 가지는 위상차 검출 회로의 설계에 관한 연구)

  • Byun, Kwang-Kyun;Kang, Ey-Goo;Kim, Dong-Nam;Oh, Reum;Sung, Man-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3117-3119
    • /
    • 1999
  • In this paper, a new phase detector which can detect phase difference of variable input frequency and represent as a DC voltage is designed. The proposed phase detector has detection range from $-180^{\circ}$ to $180^{\circ}$. It is implemented by digital electronic circuit. It operates from 125 kHz to 4 MHz frequency of input signal and it's maximum phase error is $360/256^{\circ}$.

  • PDF

A Study on Signal Circuit of the Self Diagnosis Type Triple Infrared Flame Detector (삼파장 적외선식 불꽃감지기의 자가진단 회로 개발)

  • Song, Hyun Seon;Lee, Yeu Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.69-74
    • /
    • 2013
  • There is needed the triple pyroelectric Infrared flame detector to really recognize problem, for the prevention and early suppression of fire. This system recognizes the characteristics of fire sources in various type and is communicated the message to the operators. Therefore, the prevention and early suppression of fire is available. Especially this paper focuss on development of the self diagnosis type flame detector for preventing malfunction comparing of basic and detected values.

Detection of the Ultrasonic Signals due to Partial Discharges in a 154kV Transformer

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Hee-Ro
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.297-303
    • /
    • 2002
  • We have developed an on-line ultrasonic detector to monitor partial discharge in an operating transformer. The ultrasonic sensor has 150[KHz] resonance frequency and contains a pre-amplifier with 60[㏈] gain. The on-line ultrasonic detector has 50~300[KHz] frequency band-pass filter to remove electrical and mechanical noises from the transformer. This detector has an ultrasonic signal discrimination algorithm which discriminates ultrasonic signals due to partial discharge in a transformer. A moving average method of ultrasonic signal number was employed to effectively monitor the increasing trend of the partial discharge. This paper describes an experience of partial discharge detection in a 154[㎸] operating transformer using an ultrasonic detector. With regards to gas analysis in oil, C2H2 gas was produced with a warning level in this transformer We detected ultrasonic signals on the transformer steel wall, and estimated the position of partial discharge. With further inspection, we found carbonized marks due to partial discharge on the supporting bolt which fastens the windings.

Design of Collecting System for Traffic Information using Loop Detector and Piezzo Sensor (루프검지기와 피에조 센서를 이용한 교통정보 수집시스템 설계)

  • Yang, Seung-Hun;Han, Kyong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2956-2958
    • /
    • 2000
  • This paper describes the design of a real time traffic data acquisition system using loop detector and piezzo sensor. Loop detector is the cheapest method to measure the speed and piezzo is used to detect the vehicle axle information. A ISA slot based I/O board is designed for data acquisition and PC process the raw traffic data and transfer the data to the host system. Simulation kit is designed with toy car kits. simulated loop detector and piezzo sensor. The data acquisition system collects up to 10 lane highway traffic data such as vehicle count. speed. length axle count. distance between the axles. The data is processed to generate traffic count, vehicle classification, which are to be used for ITS. The system architecture and simulation data is included and the system will be tested for field operation.

  • PDF

The Effect of Multiple Energy Detector on Evidence Theory Based Cooperative Spectrum Sensing Scheme for Cognitive Radio Networks

  • Khan, Muhammad Sajjad;Koo, Insoo
    • Journal of Information Processing Systems
    • /
    • v.12 no.2
    • /
    • pp.295-309
    • /
    • 2016
  • Spectrum sensing is an essential function that enables cognitive radio technology to explore spectral holes and resourcefully access them without any harmful interference to the licenses user. Spectrum sensing done by a single node is highly affected by fading and shadowing. Thus, to overcome this, cooperative spectrum sensing was introduced. Currently, the advancements in multiple antennas have given a new dimension to cognitive radio research. In this paper, we propose a multiple energy detector for cooperative spectrum sensing schemes based on the evidence theory. Also, we propose a reporting mechanism for multiple energy detectors. With our proposed system, we show that a multiple energy detector using a cooperative spectrum sensing scheme based on evidence theory increases the reliability of the system, which ultimately increases the spectrum sensing and reduces the reporting time. Also in simulation results, we show the probability of error for the proposed system. Our simulation results show that our proposed system outperforms the conventional energy detector system.

The High Voltage Research of X-ray Detector Based on Amorphous Selenium (a-Se 기반의 X선 검출기에서의 고전장 간섭 연구)

  • Cha, Byung-Youl;Kang, Sang-Sik;Cho, Sung-Ho;Lee, Gyu-Hong;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.853-856
    • /
    • 2002
  • Present. direct method x-ray conversion detector is studied by abroad medical instrument and country with amorphous Selenium. And we search the method for large area x-ray detector. Amorphous-Selenium based photoreceptor is widely used on the X-ray conversion materials. But amorphous-selenium based x-ray conversion detector is broken by high voltage and leakage defect point. In this paper, We investigated top-electrode distance rate to improve defect point and high voltage broken. The result to appoint to made large area x-ray conversion detector with base data.

  • PDF

Development of Individual Trespassing Detector for Building (개체 독립형 건축물 침입감지기 개발)

  • Kim, Myung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.400-403
    • /
    • 2008
  • In this work, an individual trespassing detector using a PIR sensor to detect infrared rays only between the range of $9.4{\sim}10.4{\mu}m$ radiated from the body is proposed. This detector using FIR sensor detects not insect or object but human body, It doesn't restrict the inhabitant's behavior because the filter of pm sensor is designed to have face angle and the detector only detects the window area. The existing wide angle filter, RIR sensor, detects $30^{\circ}$ angle while the face angle filter sensor on this paper detects $11^{\circ}$ angle with 3cm of face angle filter from 2m of detecting distance. In case of interruption of electric power, 250mAh of lithium-ion battery has worked for 10 hours consuming 22mA in normal state. Meanwhile, in case of interruption of electric power, 250mAh of battery has worked for 4 hours consuming 60mA in trespassing detecting state. Projector, receptor, controller and alarm are put on one PCB in order to make it convenient to install without any special installation skill.