• 제목/요약/키워드: electrical cross-coupling

검색결과 53건 처리시간 0.023초

Modeling of a Dual Stator Induction Generator with and Without Cross Magnetic Saturation

  • Slimene, Marwa Ben;Khlifi, Mohamed Arbi;Fredj, Mouldi Ben;Rehaoulia, Habib
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.284-289
    • /
    • 2015
  • This paper discusses general methods of modelling magnetic saturation in steady-state, two-axis (d & q) frame models of dual stator induction generators (DSIG). In particular, the important role of the magnetic coupling between the d-q axes (cross-magnetizing phenomenon) is demonstrated, with and without cross-saturation. For that purpose, two distinct models of DSIGs, with and without cross-saturation, are specified. These two models are verified by an application that is sensitive to the presence of cross-saturation, to prove the validity of these final methods and the equivalence between all developed models. Advantages of some of the models over the existing ones and their applicability are discussed. In addition, an alternative is given to evaluate all saturation factors (static and dynamic) by just calculating the static magnetizing inductance which is simply the magnitude of the ratio of the magnetizing flux to the current. The comparison between the simulation results of the proposed model with experimental results gives a good correspondence, especially at startup.

고출력(25GW)글라스레이저시스템의 개발에 관한 연구

  • 강형부
    • 전기의세계
    • /
    • 제30권9호
    • /
    • pp.582-588
    • /
    • 1981
  • The laser parameters such as a population inversion density, a stimulated emission cross section and loss factor in the glass laser amplifier medium were experimentally determined in order to analyse the properties of laser amplification. Using these parameters, the rate equations were approximately solved and the properties of laser amplification were analysed. An experiment of two-stage amplifier of Q-switching laser pulse was performed and the maximum output power was 1.1 GW, 33J. The several problems such as a laser solarization and a laser coupling in laser amplification were resolved.

  • PDF

신경 회로망을 이용한 유도 전동기의 전류제어 (Current Control of Induction Motor using Neural Networks)

  • 박영수;서호준;김성한;서삼준;김동식;박귀태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.66-68
    • /
    • 1997
  • In this paper, our interest is the identification and control of nonlinear dynamic plant, induction motor, by using neural networks. We usually use vector control in the induction motor such as in the DC motor. When we go over the inputs of voltage source invertor, we can find that torque current and flux current couple each other in the induction motor. Before putting control inputs in the system, we should remove the coupling terms which we already know from them. But we should consider that cross coupling terms have time-varying variables. In this paper, we identified the parameter of induction motor by using neural networks and designed the controller with identified parameters. Through this procedure we obtained compensated inputs which are decoupled each other. Using induction motor currents control, we can make the d axis current hold constant value and control the q axis current at the same time.

  • PDF

전력선 접지와 매설배관의 이격거리 실증실험 사례 조사 (Investigation of the Experiment for Separation Distance between Powerline Earth and Pipelines)

  • 이현구;하태현;하윤철;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.87-88
    • /
    • 2006
  • There are a number of reported instances of actual pipeline rupture during power line faults caused by melting of the pipe wall. This type of hazard was considered to be among the most serious of AC effects on pipelines in an international survey, comparable to the personnel safety hazard. Moreover, resistance coupling is not only a risk when the pipeline parallels a power line but also when they cross. One method of minimizing the effects of resistive coupling is by maintaining an appropriate separation distance between the pipeline and tower. This paper investigate the experiment for separation distance between the powerline earth and pipelines.

  • PDF

Adaptive Decoupling for IPM Machine(ICCAS 2005)

  • Cho, Sung-Uk;Park, Seung-Kyu;Ahn, Ho-Kyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1617-1620
    • /
    • 2005
  • The current control for interior permanent magnet machines is more complicate than surface permanent magnet machine because of its torque characteristic depending on the reluctance. For high performance torque control, it requires state decoupling between the d-current and q-current dynamics. However the variation of the inductances, which couples the state dynamics of the currents, makes the state decoupling difficult. So some decoupling methods have developed to cope this variations and each current can be regulated independently. This paper presents a novel approach for fully decoupling the states cross-coupling using parameter adaptation. The adaptation method is based on the error between reference currents and the currents with state decoupling which have to follow the references. This method is more object-oriented than the other online parameter estimation methods in IPM machine and other electrical machines

  • PDF

Coordination Control of Multiple Electrical Excited Synchronous Motors and Its Application in High-Power Metal-Rolling Systems

  • Shang, Jing;Nian, Xiaohong;Liu, Yong
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1781-1790
    • /
    • 2016
  • This study focuses on the coordination control problem of multiple electrical excited synchronous motor systems. A robust coordination controller is designed on the basis of cross coupling and an interval matrix. The proposed control strategy can deal with load uncertainty. In addition, the proposed control strategy is applied to a high-power metal-rolling system. Simulation and experiment results demonstrate that the proposed control strategy achieves good dynamic and static performance. It also shows better coordination performance than traditional proportional-integral controllers.

Die-to-Die Parasitic Extraction Targeting Face-to-Face Bonded 3D ICs

  • Song, Taigon;Lim, Sung Kyu
    • Journal of information and communication convergence engineering
    • /
    • 제13권3호
    • /
    • pp.172-179
    • /
    • 2015
  • Face-to-face (F2F) bonding in three-dimensional integrated circuits (3D ICs), compared with other bonding styles, is closer to commercialization because of its benefits in terms of density, yield, and cost. However, despite the benefits that F2F bonding expect to provide, it's physical nature has not been studied thoroughly. In this study, we, for the first time, extract cross-die (inter-die) parasitic elements from F2F bonds on the full-chip scale and compare them with the intra-die elements. This allows us to demonstrate the significant impact of field sharing across dies in F2F bonding on full-chip noise and critical path delay values. The baseline method used is the die-by-die method, where the parasitic elements of individual dies are extracted separately and the cross-die parasitic elements are ignored. Compared with this inaccurate method, which was the only method available until now, our first-of-its-kind holistic method corrects the delay error by 25.48% and the noise error by 175%.

Plasmon-enhanced Infrared Spectroscopy Based on Metasurface Absorber with Vertical Nanogap

  • Hwang, Inyong;Lee, Jongwon;Jung, Joo-Yun
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.275-279
    • /
    • 2018
  • In this study, we introduce a sensing platform based on a plasmonic metasurface absorber (MA) with a vertical nanogap for the ultrasensitive detection of monolayer molecules. The vertical nanogap of the MA, where the extremely high near-field is uniformly distributed and exposed to the external environment, is formed by an under-cut structure between a metallic cross nanoantenna and the mirror layer. The accessible sensing area and the enhanced near-field of the MA further enhance the sensitivity of surface-enhanced infrared absorption for the target molecule of 1-octadecanethiol. To provide strong coupling between the molecular vibrations and plasmonic resonance, the design parameters of the MA with a vertical nanogap are numerically designed.

2중 인버터 시스템을 갖는 해상용 풍력발전기의 3상 평형성에 관한 연구 (A Study on 3-Phase Balance of Offshore Wind Generator with Dual Inverter System)

  • 서장호
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.23-30
    • /
    • 2013
  • This paper shows the method of winding connection and the balance of three phase of dual inverter systems used for offshore wind power generator. In order to satisfy low cost manufacturing of large scaled wind generator, the number of slot per pole per phase should be reduced. For this reason, in this research, the number is selected as '1' which is the minimum number that stator can have. Based on the prototype machine, three types of machine for the analysis are selected, and various performances especially in terms of electrically balanced condition are also investigated. Moreover, in this paper, new inductance modeling of dual 3-phase considering cross-coupling between two inverter systems is proposed. The several inductances such as mutual-, synchronous inductances are studied. By using FEA, based on calculated the flux linkage of d and q-axis, the validity of the proposed inductance modeling is confirmed.

열경화성 EPOXY수능의 2인경화촉진에 따른 Treeing 현상에 관한 연구 (A Study on the Treeing Phenomenon due to the Post-Cure Conditions of the Thermo-Setting Epoxy Resin)

  • 조정수;김종경;백선환;이종호
    • 대한전기학회논문지
    • /
    • 제37권6호
    • /
    • pp.406-413
    • /
    • 1988
  • This paper is to investigate relationships between tree inception voltage, tree extension or treeing breakdown voltage and physical characteristics changing as parameter of the post-cured conditions of thermo-setting epoxy resin. According to the results in this paper, the optimal tree inception voltage and treeing breakdown voltage of the samples are obtained for the sample post cured for 15 hours at 100 'C. It can be noticed that these results are closely related with the state of interior molecule coupling and three-dimen sional cross-linked of thermo-setting epoxy resin. And tree inception, tree extension and treeing breakdown of the samples are affected significantly on the post-cured conditions and the cooling method after post-cured of thermo-setting epoxy resin. Moreover, the tree extension by ambient temperature are closely related with softening temperature of thermo-setting epoxy resin.

  • PDF