Improving the Performance of Hot Rolling Process through Cross Control (Cross Control 기법을 통한 열연 공정의 성능 개선)

  • Jung, Jae-Kyung;Park, Ju-Hyun;Shim, Woo-Chul;Kwon, Oh-Min;Won, Sang-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.561-563
    • /
    • 1999
  • The looper of a hot strip finishing mill is installed between each pair of stands and plays a key role to enhance the product quality of strip by controlling the tension and height of strip in each inter-stand. Though the conventional looper control has achieved the mass products of strip so far, it has difficulties not only tuning gains by means of errors which are caused by coupling effects between strip tension and looper angle both utilizing tension feedback. Therefore, the non-interactive control employing cross controller and tension feedback has been introduced in looper control system in order to overcome the coupling effects existing between tension and looper angle and track the reference tension efficiently. In this paper, we present the cross controllers which play a role to decouple reciprocal effects between tension and looper angle and show better performance.

  • PDF

Characteristic Analysis of Interior Permanent Magnet Motor considering Cross-Coupling Effect (IPM의 자계 Cross-Coupling특성엘 관한 연구)

  • Kwak, Sang-Yeop;Kim, Jae-Kwang;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.991-993
    • /
    • 2003
  • 본 논문에서는 영구자석 기기에서 발생하는 d-q축간의 상호 포화(cross saturation) 문제에 대해 다루었고, 이를 고려한 d축과 q축의 전류에 따른 전동기의 특성값을 수치 해석적으로 도출하는 방법을 제시하였다. 아울러 다층 회전자 구조를 지닌 매입형 영구자석 전동기(multi-layer buried magnet synchronous motor)의 d축 및 q축 인덕턴스 값을 교차 결합 특성(Cross-Coupling)을 고려하여 수치 해석적 기법을 통해 도출하였으며, 실험값과의 비교를 통해서 기존의 해석 방법보다 우수함을 입증하였다.

  • PDF

Estimation of Microwave Path Loss and Cross-Polarization Coupling in a Simple Urban Area

  • Yisok Oh;No, Chan-Ho;Sung, Hyuk-Je;Lee, Byung-Hoon;Koo, Yeon-Geon
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.1
    • /
    • pp.30-36
    • /
    • 2001
  • Whereas it is well known that microwave propagation around corners of urban area is estimated well by the uniform geometrical theory of diffraction (UTD), it is not clear how much depolarization occurs at a given receiver position and how much transmission through walls affects to total path loss. This paper presents the results of the ray tracing simulation to answer these questions. Simulations of microwave propagation around corners were performed for various line-of-sight (LOS) and out-of-sight(OOS) positions of a receiver, by summing the electrical fields of reflected, diffracted and transmitted rays coherently. Since height difference between transmitter and receiver, as well as ground plane, causes depolarization, the ray tracing simulation estimates the cross-polarization coupling. It was found that the cross-polarization coupling decreases as receiver moves away from transmitter. Another part of the study focused on the signal transmitted through building walls of the corner. It was found that the transmitted field is dominant at OOS region when the conductivity of the walls is low (for example, lower than 0.0l S/m). The simulation results of the ray tracing technique in this study agreed well with an experimental measurement around corners.

  • PDF

Current Decoupling Control for the Three-level PWM Rectifier with a Low Switching Frequency

  • Yuan, Qing-Qing;Xia, Kun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.280-287
    • /
    • 2015
  • Three-level PWM rectifiers applied in medium voltage applications usually operate at low switching frequency to keep the dynamic losses under permitted level. However, low switching frequency brings a heavy cross-coupling between the current components $i_d$ and $i_q$ with a poor dynamic system performance and a harmonic distortion in the grid-connecting current. To overcome these problems, a mathematical model based on complex variables of the three-level voltage source PWM rectifier is firstly established, and the reasons of above issues resulted from low switching frequency have been analyzed using modern control theory. Then, a novel control strategy suitable for the current decoupling control based on the complex variables for $i_d$ and $i_q$ is designed here. The comparisons between this kind of control strategy and the normal PI method have been carried out. MATLAB and experimental results are given in detail.

Multiple Decoupling Current Control Strategies for LCL Type Grid-Connected Converters Based on Complex Vectors under Low Switching Frequencies

  • Liu, Haiyuan;Shi, Yang;Guo, Yinan;Wang, Yingjie;Wang, Wenchao
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.1034-1044
    • /
    • 2019
  • In medium-voltage and high-voltage high-power converters, the switching devices need to operate at a low switching frequency to reduce power loss and increase the power capacity. This increases the delay of the signal sampling and PWM. It also makes the cross-couplings of the d-q current components more severe. In addition, the LCL filter has three cross-coupling loops and is prone to resonance. In order to solve these problems, this paper establishes a complex vector model of an LCL type grid-connected converter. Based on this model, two multiple decoupling current control strategies with passive damping / notch damping are proposed for the LCL type grid-connected converter. The proposed strategies can effectively eliminate the cross-couplings of the converter, achieve independent control of the d-q current components, expand the stable region and suppress the resonance of the LCL filter. Simulation and experimental results verify the correctness of the theoretical analysis and the feasibility of the proposed strategies.

Analysis on Parameter Estimation Error of Permanent Magnet Synchronous Machine(PMSM) Considering Cross Coupling Effect (교차 결합 현상에 의한 영구자석 동기전동기의 제정수 추정 오차 분석)

  • Chung, Euihoon;Ha, Jung-Ik
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.101-102
    • /
    • 2016
  • 영구자석 동기전동기(PMSM)의 효율적인 구동을 위해 전동기의 제정수를 실시간으로 정확하게 추정하는 것이 매우 중요하다. 대부분의 전동기 제정수 추정 기법은 전동기의 교차 결합 현상(Cross coupling effect)을 고려하지 않은 전동기 모델을 이용한다. 본 논문에서는 영구자석 동기전동기에서 기존의 제정수 추정 기법을 적용할 경우 교차 결합 현상에 의해 발생하는 제정수의 추정 오차를 수학적으로 분석하고 이를 시뮬레이션을 통해 검증하였다.

  • PDF

Deadbeat Direct Active and Reactive Power Control of Three-phase PWM AC/DC Converters

  • Gandomkar, Ali;Seok, Jul-Ki
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1634-1641
    • /
    • 2018
  • This study focuses on a high-performance direct active and reactive power controller design that is successfully applicable to three-phase pulse width modulation (PWM) AC/DC converters used in renewable distributed energy generation systems. The proposed controller can overcome the sluggish transient dynamic response of conventional controllers to rapid power command changes. Desired active and reactive powers can be thoroughly obtained at the end of each PWM period through a deadbeat solution. The proposed controller achieves an exact nonlinear cross-coupling decoupling of system power without using a predefined switching table or bang/bang hysteresis control. A graphical and analytical analysis that naturally leads to a control voltage vector selection is provided to confirm the finding. The proposed control strategy is evaluated on a 3 kW PWM AC/DC converter in the simulation and experiment.

A Novel Disturbance Observer Design for Dynamic Systems (동적 시스템을 위한 새로운 외란 관측기 설계)

  • Sho, Jae-Hyuk;Chung, Chung-Choo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.388-391
    • /
    • 2003
  • Disturbance observer(DOB) is effective to enhance the performance of system in the presence of disturbances. Various types of disturbance observer have been proposed to improve sensitivity function of system. However, it has been observed that current DOBs tend to bring poor transient response due to cross-couplings. This paper proposes a new type of disturbance observer to reduce effect of cross-couplings and provide simpler structure than Dual DOB. Finally, we verify the performance of the proposed DOB through numerical simulations.

  • PDF

Electrical Properties of Silicone Rubber Filled with Surface Treated Alumina Trihydrate

  • Jung, Se-Young;Kim, Byung-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.3
    • /
    • pp.134-140
    • /
    • 2006
  • The effect of surface treatment of fillers on the mechanical, electrical properties, and tracking performance of silicone rubber insulators have been investigated. For base polymer, $\alpha,\;\omega$) vinyl poly(dimethyl-methylphenyl) siloxane(VPMPS) containing dimethyl siloxane and methylphenyl siloxane was prepared by the equilibrium polymerization. High voltage silicone rubber composites(HVSRC) were prepared from VPMPS, nano-silica, and alumina trihydrate (ATH) modified by various coupling agents. Bound rubber of uncured silicone rubber, cross-linking density of the vulcanizate as well as the mechanical, electrical properties, and tracking performance were measured.

IPM control using by neural network and sliding mode control (신경회로망과 슬라이딩 모드제어를 이용한 IPM 제어)

  • Kim, Jae-Hoon;Yoon, Tae-Sung;Park, Seung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1587-1588
    • /
    • 2007
  • IPM(Interior Permanent Magnet) Machine의 전류 제어는 자기저항에 의존하는 토크특성 때문에 SPM(Surface Permanent Ma- gnet) Machine보다 복잡하다. 고성능 토크제어를 위해서는 d축 전류와 q축 전류의 동특성간의 상태 decoupling이 요구된다. 그러나 전류의 상태 동특성이 coupling된 인덕턴스의 변화(온도, 파라미터들의 부정확한 측정값)는 상태 decoupling을 어렵게 한다. 그래서 이러한 변화와 각각의 전류가 독립적으로 제어될 수 있게 여러 decoupling 방법들에 초점이 맞춰지고있다. 본 연구는 외란에 강하고, 특히 인덕턴스의 변화와 상관없는 이상적인 토크제어를 하기 위해 신경회로망을 이용하여 슬라이딩 평면(sliding surface)을 구성하고, SMC(Sliding Mode Control)를 이용하여 상태 cross-coupling의 decoupling을 위한 새로운 접근을 제안한다. 이 방법은 PI제어 성능과 SMC의 강인성을 알고리즘을 이용하여 결합한 것이라고 볼 수도 있다.

  • PDF