• Title/Summary/Keyword: electrical connection

Search Result 1,132, Processing Time 0.026 seconds

A Study on Safe Permanent Joint Type Multiple Socket-Outlets Development without Soldering Crimped Connection (안전형 비납땜 틀고정 영구 접속형 멀티콘센트 개발에 관한 연구)

  • Cho, Won-Seok;Lee, Wi-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.47-54
    • /
    • 2015
  • Normally, multiple socket-outlet is manufactured with soldered, welded permanent connection (termination). Because this procedure is very non-environmental and requires many labor forces, many companies skip this process. To solve this these problems, this research had to design permanent joint type multiple socket-outlet, develop safer multiple socket-outlet than is sold in markets. Progressing this research, we took 3 steps. First, we had to design device for fixing a frame suitable for multiple socket-outlet. Second, this multiple socket-outlet must pass fundamental standards through international standard (IEC 60884-1) and Korean standard (K 60884-1) tests. Third, it had to pass both several mechanical and electrical tests which is more strict than fundamental standards and vibration and impact tests following KS standards for enhancing its safety. After finishing 3 steps, we could obtain objective and fair data, develop environmental permanent joint type multiple socket-outlet without soldering crimped connection.

Method of network connection management in module based personal robot for fault-tolerant (모듈기반 퍼스널 로봇의 결함 허용 지원을 위한 네트워크 연결 유지 관리 기법)

  • Choi, Dong-Hee;Park, Hong-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.300-302
    • /
    • 2006
  • Middleware offers function that user application program can transmit data independently of network device. Connection management about network connection of module is important for normal service of module base personal robot. Unpredictable network disconnection is influenced to whole robot performance in module base personal robot. For this, Middleware must be offer two important function. The first is function of error detection and reporting about abnormal network disconnection. Therefore, middleware need method for network error detection and module management to consider special quality that each network device has. The second is the function recovering that makes the regular service possible. When the module closed from connection reconnects, as this service reports connection state of the corresponding module, the personal robot resumes the existing service. In this paper proposed method of network connection management for to support fault tolerant about network error of network module based personal robot.

  • PDF

Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City (에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.

A Study on the Polarity Discrimination Method of the Stator Windings for 3 Phase Induction Motors based on the Residual Magnetism and I Winding Connection (잔류자기와 I 결선에 의한 3상유도전동기 고정자 권선의 극성판별법에 대한 연구)

  • Choi, Soon-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.72-77
    • /
    • 2015
  • When connecting 6 lead wires from stator windings to the terminals of 3 phase induction motors for Y or ${\triangle}$ connection, it is feared that the polarities of windings could be reversed each other if the wire tags are lost or erased, resulting in inadmissibly high current to motors in case of starting. To protect motors against such situations, some test procedures are necessary during wire connection which need to be easy ways to electricians without particular tools except a general multi-tester and with less time-consuming in the field. This study focuses on a test measure to satisfy these requirements which is able to provide them a convenient procedure for winding polarity discrimination considering the field condition. Here, the proposed measure utilizes the residual magnetism of the rotor and checks the indication of voltage or current at windings which are induced by the residual flux of rotor when rotating it by hands with 3 stator windings connected in the form of I connection. Principle characteristics and experiment results for this method are analyzed in the view of the effectiveness and applicability for the winding polarity discrimination.

Analysis on Current Limiting Characteristics of Series Connection-type SFCL with Two Magnetically Coupled Circuits Applied into a Simulated Power System (모의전력계통에 적용된 두 개의 자기결합 회로를 갖는 직렬연결형 초전도 전류제한기의 전류제한 특성 분석)

  • Ko, Seok-Cheol;Lee, Shin-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.1
    • /
    • pp.68-72
    • /
    • 2013
  • The series connection-type superconducting fault current limiter (SFCL) with two magnetically coupled circuits was suggested and its effectiveness through the analysis on the current limiting and recovery characteristics was described. The fault current limiting characteristics of the proposed SFCL as well as the load voltage sag compensating characteristics according to the winding direction were investigated. To confirm the fault current limiting and the voltage sag suppressing characteristics of the this SFCL, the short-circuit tests for the simulated power system with the series connection-type SFCL were carried out. The series connection-type SFCL designed with the additive polarity winding was shown to perform more effective fault current limiting and load voltage sag compensating operations through the fast quench occurrence right after the fault appears and the fast recovery operation after the fault removes than that with the subtractive polarity winding.

Effects of Human Safety due to Leakage Current by Outdoor Electrical Facility in the Submerged Condition(I) (옥외 전기시설물 침수시 누설전류에 의한 인체영향(I))

  • Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Hyeong;Bae, Jeong-Hyo;Lee, Ji-In;Kim, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.244-246
    • /
    • 2002
  • In this paper, We studied about effects of human safety due to leakage current on the point of cable connection for outdoor electrical facility in the submerged condition and conducted its evaluation in the testing field. In this case, the reason of leakage on the point of cable connection is caused by formation of electrical pass between the grounded outdoor electrical facility and the enclosure of electrical facility which is connected to grounding system.

  • PDF

Using PC for Connection Between LONWORKS System and The Internet (PC를 이용한 LONWORKS 시스템과 인터넷의 연결 구현)

  • Park, Jin-Seok;Shim, Il-Joo;Kim, Beom-Soo;Leem, Chae-Sung;Park, Gwi-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.443-449
    • /
    • 2002
  • In this paper, we propose a programmable method that can connect the control network with the Internet by using an ordinary PC, which is operated by GNU/LINUX. We make a physical connection between an ordinary PC and control network. Then, a PC can be bound with a particular control network. Moreover, numerous PCs that are bound with particular control networks have addresses of there own on the Internet. So, these PCs are connected each other very well. Consequently, all control networks can be observed and controlled with data transfer between these PCs.

  • PDF

Effects of Human Safety due to Leakage Current by Outdoor Electrical Facility in the Submerged Condition(II) (옥외 전기시설물 침수시 누설전류에 의한 인체영향(II))

  • Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong;Bae, Jeong-Hyo;Lee, Ji-In;Kim, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.247-249
    • /
    • 2002
  • In this paper, We studied, about effects of human safety due to leakage current on the point of cable connection for outdoor electrical facility in the submerged condition and conducted its evaluation in the testing field. In this case, the reason of leakage on the point of cable connection is caused by formation of electrical pass between the grounded outdoor electrical facility and the other outdoor electrical facility which is disconnected to grounding system.

  • PDF

Characteristics of Hybrid-Type SFCL according to the Parallel Connection of Secondary Windings (2차권선의 병렬연결에 따른 하이브리드형 초전도 한류기의 특성)

  • Hwang, Jong-Sun;Cho, Yong-Sun;Choi, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.208-211
    • /
    • 2006
  • We have analyzed operating characteristics of hybrid-type superconducting fault current limiter (SFCL) according to the parallel connection of secondary windings with $YBa_{2}Cu_{3}O_{7}$ (YBCO) films. The turn ratio between the primary and secondary windings of each reactor was 63:21. Hybrid-type SFCL using a transformer with parallel reactors could reduce the unbalanced quench caused by differences of the critical current density between YBCO films. We found that hybrid-type SFCL having parallel connection induced simultaneous quench between the superconducting elements. The quench-starting point at this time was almost same. When the applied voltage was 200V, the limiting current in the hybrid-type SFCL with a serial connection was lowered to 34 percent than that in the SFCL with a parallel connection. In the meantime, when the voltage generated in the superconducting elements was the same, the current value in the parallel connection was 60 percent less than in the serial connection. The voltage generated in the primary winding also showed the similar behavior. In conclusion, we found that the fault current was limited more effectively in the SFCL with the serial connection but the power burden of the superconducting elements was reduced in the parallel connection.

  • PDF

Design Optimization for High Power Inverters

  • Schroder D.;Kuhn H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.713-717
    • /
    • 2001
  • This paper focuses on a network model for GCTs which can be used to investigate high power circuits with or without using RC-snubbers. The series connection of GCTs is commonly applied in the high power inverter field. Here expensive and space-consuming snubbers are applied, to overcome the problem of an asymmetric distribution of the blocking voltage among the single GCTs. As an alternative to large snubbers, a new active gate drive concept is proposed and investigated by simulation.

  • PDF