• 제목/요약/키워드: electrical arc furnace

검색결과 44건 처리시간 0.037초

수요관리를 위한 아크로 운전 상태에 따른 고조파 연구 (A Study of Harmonics by Arc Furnace Operating for Demand Side Management)

  • 박경호;김재철;박현택;임상국;오동환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.17-19
    • /
    • 2003
  • Electric arc furnace has consumed plenty of power. Hence electric arc furnace can be expected to use for demand side management. When electric arc furnace use for demand side management, electric arc furnace frequently occur a starting and a stop. Electric arc furnace irregularity change consumption of power. Due to character of time-varing and non-linear, electirc arc furnace has a problem with voltage quality(flicker, harmonics). Producted harmonic in electric art furnace is different any harmonic source because of electric arc furnace peculiar operating. Accordingly, analysis for generated harmonic in electric arc furnace operating is demanded. This paper analyze effect of harmonic by arc furnace operating.

  • PDF

Thyristor Rectifier for DC Arc Furnace with Enhanced Arc Stability

  • Jung, Kyungsub;Suh, Yongsug;Kim, Taewon;Park, Taejun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.498-499
    • /
    • 2011
  • In this paper, the fundamental features of the arc stability DC arc furnace have been investigated, from the converter point of view. To compare of measurement arc data from DC arc furnace and the advanced arc simulations of magneto-hydrodynamics (MHD) and the well known Cassie-Mayr arc model have been extensively used. The MHD based arc simulation has been validated in the subcomponent level, for the free burning arc set up in the laboratory. The arc simulation predicted the arc voltage for different currents with the accuracy which satisfies engineering requirements. It has been shown that the arc current steepness at current zero determines the arc stability, and the associated peak arc resistance can be used as its quantitative measure. Based on the presented insight into the DC arc stability, a converter topology solution which realizes an optimal arc stability has been proposed. The main results presented in this paper provide a design guideline for the future DC arc furnace converter topology developments.

  • PDF

전압변동 측면에서 본 아크로 부하가 전력계통에 미치는 영향 검토 (Analysis of effects of the arc-funace on the power system from the viewpoint of voltage regulation)

  • 박현택;김재철;박경호;임상국
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.366-369
    • /
    • 2004
  • Arc-furnace is one of the large loads in the electric power system. When the arc-furnace operates, it may cause a bus voltage fluctuation in the power system, because it consumes a lot of reactive power. In this paper, we simulated this phenomenon by using a PSAF program with on-site measured arc-furnace load. The simulated results show that the fluctuation of bus voltage adjacent the arc-furnace was varied from $4.3%{\sim}7.8%$ the normal voltage because of reactive power consumption by arc-furnace. Therefore, we expect this study will come into use as the basic information on the probability of the demand control

  • PDF

전기로 대전류 케이블 고장진단 알고리즘 개발 (Development of a Fault Diagnosis Algorithm on a High Current Cable of Arc Furnace)

  • 김상우;장유진
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권3호
    • /
    • pp.115-118
    • /
    • 2006
  • In the steel industry, a steel melting electric arc furnace is used to produce both carbon and alloy steels. Steel scrap which is charged into the furnace is heated by means of electric arc between graphite electrodes and the scrap. In this melting process, current is supplied to the furnace through HCC(high current cable) which connect the furnace and transformer. Four HCCs are assigned to each phase in our system to divide the current. Since a sudden cable breaking result in the shutdown of melting process, an aging detection of HCC is very important for both an improvement of productivity and cost reduction. In this paper, the aging of the HCC is estimated by using the current ratio between four HCCs.

Electric Arc Furnace Voltage Flicker Mitigation by Applying a Predictive Method with Closed Loop Control of the TCR/FC Compensator

  • Kiyoumarsi, Arash;Ataei, Mohhamad;Hooshmand, Rahmat-Allah;Kolagar, Arash Dehestani
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.116-128
    • /
    • 2010
  • Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.

아크로 긴급 차단 시 계통 전압변동 영향 평가 (Assessment of effects on Arc-Furnace Load cutailment in Emergency)

  • 박현택;김재철;임상국;오동환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.57-59
    • /
    • 2004
  • Arc-furnace is one of the large loads in the electric power system. When the arc-furnace operates, it may cause a bus voltage fluctuation in the power system, because it consumes a lot of reactive power. In this paper, we simulated this phenomenon by using a PSAF program with on-site measured arc-furnace load for different amount of cutailment load.

  • PDF

아크로 부하패턴을 고려한 전력계통 전압변동 분석 (Analysis of effects of the arc-funace on the power system Considering the toad pattern of arc-funace)

  • 박현택;김재철;손학식;임상국;오동환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.295-297
    • /
    • 2004
  • Arc-furnace is one of the large loads in the electric power system. When the arc-furnace operates, it may cause a bus voltage fluctuation in the power system, because it consumes a lot of reactive power. In this paper, we simulated this phenomenon by using a PSAF program with on-site measured arc-furnace load. The simulated results show that the fluctuation of bus voltage adjacent the arc-furnace was varied from $4.3\%\sim7.8\%$ the normal voltage because of reactive power consumption by arc-furnace. Therefore, we expect this study will come into use as the basic information on the probability of the demand control

  • PDF

전기 아크로 운전 상태에 따른 고조파 해석 (Harmonics Analysis for Electric Arc Furnace According to the Operation Condition)

  • 김재철;박경호;박현택;문종필;임상국;손학식
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.118-125
    • /
    • 2004
  • 철강 소비가 늘어나고, 전기아크로 운영기술의 발전에 따라 아크로의 사용이 증가하고 있다. 그러나 전기아크로의 사용이 늘어날수록 계통에는 악영향을 미치게 된다. 즉, 전력품질 문제인 전압 및 전류 고조파, 상 불평형, 역률 저하, 전압 플리커 등의 문제가 발생하고 있다. 여기서는 시변 특성과 비선형 특성을 갖는 고조파에 대하여 해석하였다. 우선 전기 아크로가 포함된 전력계통 모델을 만들고, 전기 아크로의 다양한 운전 조건에 따라 발생된 고조파가 계통에 미치는 영향을 분석하였다. 또한 고조파 저감 대책으로 고조파 필터를 설계하여 그 영향을 검토하였다.

Power Quality Impacts of an Electric Arc Furnace and Its Compensation

  • Esfandiari Ahmad;Parniani Mostafa;Mokhtari Hossein
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.153-160
    • /
    • 2006
  • This paper presents a new compensating system, which consists of a shunt active filter and passive components for mitigating voltage and current disturbances arising from an Electric Arc Furnace (EAF). A novel control strategy is presented for the shunt active filter. An extended method based on instantaneous power theory in a rotating reference frame is developed for extraction of compensating signals. Since voltages at the point of common coupling contain low frequency interharmonics, conventional methods cannot be used for dc voltage regulation. Therefore, a new method is introduced for this purpose. The passive components limit the fast variations of load currents and mitigate voltage notching at the Point of Common Coupling (PCC). A three-phase electric arc furnace model is used to show power quality improvement through reactive power and harmonic compensation by a shunt active filter using the proposed control method. The system performance is investigated by simulation, which shows improvement in power quality indices such as flicker severity index.

전기로 High Current Cable 고장진단 알고리즘 개발 (Developing a fault diagnosis algorithm on a high current cable of arc furnace)

  • 최성진;장유진;김상우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.573-575
    • /
    • 2005
  • In the steel industry, a steel melting electric arc furnace is used to produce both carbon and alloy steels. Steel scrap which is charged into the furnace is heated by means of electric arc between graphite electrodes and the scrap. In this melting process, current is supplied to the furnace through HCC(high current cable) which connect the furnace and transformer. Four HCCs are assigned to each phase in our system to divide the current. Since a sudden cable breaking result in the shutdown of melting process, an aging detection of HCC is very important for both an improvement of productivity and cost reduction. In this paper, the aging of the HCC is estimated by using the current ratio between four HCCs.

  • PDF