• Title/Summary/Keyword: electrical arc furnace

Search Result 44, Processing Time 0.033 seconds

A Study of Harmonics by Arc Furnace Operating for Demand Side Management (수요관리를 위한 아크로 운전 상태에 따른 고조파 연구)

  • Park, Kyung-Ho;Kim, Jae-Chul;Park, Hyun-Teak;Im, Sang-Kug;Oh, Dong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.17-19
    • /
    • 2003
  • Electric arc furnace has consumed plenty of power. Hence electric arc furnace can be expected to use for demand side management. When electric arc furnace use for demand side management, electric arc furnace frequently occur a starting and a stop. Electric arc furnace irregularity change consumption of power. Due to character of time-varing and non-linear, electirc arc furnace has a problem with voltage quality(flicker, harmonics). Producted harmonic in electric art furnace is different any harmonic source because of electric arc furnace peculiar operating. Accordingly, analysis for generated harmonic in electric arc furnace operating is demanded. This paper analyze effect of harmonic by arc furnace operating.

  • PDF

Thyristor Rectifier for DC Arc Furnace with Enhanced Arc Stability

  • Jung, Kyungsub;Suh, Yongsug;Kim, Taewon;Park, Taejun
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.498-499
    • /
    • 2011
  • In this paper, the fundamental features of the arc stability DC arc furnace have been investigated, from the converter point of view. To compare of measurement arc data from DC arc furnace and the advanced arc simulations of magneto-hydrodynamics (MHD) and the well known Cassie-Mayr arc model have been extensively used. The MHD based arc simulation has been validated in the subcomponent level, for the free burning arc set up in the laboratory. The arc simulation predicted the arc voltage for different currents with the accuracy which satisfies engineering requirements. It has been shown that the arc current steepness at current zero determines the arc stability, and the associated peak arc resistance can be used as its quantitative measure. Based on the presented insight into the DC arc stability, a converter topology solution which realizes an optimal arc stability has been proposed. The main results presented in this paper provide a design guideline for the future DC arc furnace converter topology developments.

  • PDF

Analysis of effects of the arc-funace on the power system from the viewpoint of voltage regulation (전압변동 측면에서 본 아크로 부하가 전력계통에 미치는 영향 검토)

  • Park, Hyun-Taek;Kim, Jae-Chul;Park, Kyoung-Ho;Im, Sang-Gug
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.366-369
    • /
    • 2004
  • Arc-furnace is one of the large loads in the electric power system. When the arc-furnace operates, it may cause a bus voltage fluctuation in the power system, because it consumes a lot of reactive power. In this paper, we simulated this phenomenon by using a PSAF program with on-site measured arc-furnace load. The simulated results show that the fluctuation of bus voltage adjacent the arc-furnace was varied from $4.3%{\sim}7.8%$ the normal voltage because of reactive power consumption by arc-furnace. Therefore, we expect this study will come into use as the basic information on the probability of the demand control

  • PDF

Development of a Fault Diagnosis Algorithm on a High Current Cable of Arc Furnace (전기로 대전류 케이블 고장진단 알고리즘 개발)

  • Kim, Sang-Woo;Jang, Yu-Jin
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.3
    • /
    • pp.115-118
    • /
    • 2006
  • In the steel industry, a steel melting electric arc furnace is used to produce both carbon and alloy steels. Steel scrap which is charged into the furnace is heated by means of electric arc between graphite electrodes and the scrap. In this melting process, current is supplied to the furnace through HCC(high current cable) which connect the furnace and transformer. Four HCCs are assigned to each phase in our system to divide the current. Since a sudden cable breaking result in the shutdown of melting process, an aging detection of HCC is very important for both an improvement of productivity and cost reduction. In this paper, the aging of the HCC is estimated by using the current ratio between four HCCs.

Electric Arc Furnace Voltage Flicker Mitigation by Applying a Predictive Method with Closed Loop Control of the TCR/FC Compensator

  • Kiyoumarsi, Arash;Ataei, Mohhamad;Hooshmand, Rahmat-Allah;Kolagar, Arash Dehestani
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.116-128
    • /
    • 2010
  • Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.

Assessment of effects on Arc-Furnace Load cutailment in Emergency (아크로 긴급 차단 시 계통 전압변동 영향 평가)

  • Park, Hyun-Taek;Kim, Jae-Chul;Im, Sang-Gug;Oh, Dong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.57-59
    • /
    • 2004
  • Arc-furnace is one of the large loads in the electric power system. When the arc-furnace operates, it may cause a bus voltage fluctuation in the power system, because it consumes a lot of reactive power. In this paper, we simulated this phenomenon by using a PSAF program with on-site measured arc-furnace load for different amount of cutailment load.

  • PDF

Analysis of effects of the arc-funace on the power system Considering the toad pattern of arc-funace (아크로 부하패턴을 고려한 전력계통 전압변동 분석)

  • Park Hyun Taek;Kim Jae Chul;Son Hak Sig;Kug Im Sang;Oh Dong hwan
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.295-297
    • /
    • 2004
  • Arc-furnace is one of the large loads in the electric power system. When the arc-furnace operates, it may cause a bus voltage fluctuation in the power system, because it consumes a lot of reactive power. In this paper, we simulated this phenomenon by using a PSAF program with on-site measured arc-furnace load. The simulated results show that the fluctuation of bus voltage adjacent the arc-furnace was varied from $4.3\%\sim7.8\%$ the normal voltage because of reactive power consumption by arc-furnace. Therefore, we expect this study will come into use as the basic information on the probability of the demand control

  • PDF

Harmonics Analysis for Electric Arc Furnace According to the Operation Condition (전기 아크로 운전 상태에 따른 고조파 해석)

  • Kim, Jae-Chul;Park, Kyung-Ho;Park, Hyun-Teak;Moon, Jong-Fil;Im, Sang-Kug;Son, Hag-Sig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.118-125
    • /
    • 2004
  • The use of electric arc furnace has been increasing as the steel consumption is increasing and the operation technique of electric arc furnace are developing. But as the use of electric arc furnace is increased, the furnace have produced the adverse effects of power quality: voltage and current harmonics, voltage and current imbalances, low power factor, and voltage flicker. One of the power quality problems, the harmonic have the characteristics of the time-varying and non-linear. This paper analyzed the harmonics for the various operation conditions of electric arc furnace. The power system model with electric arc furnace have been made, and the harmonic's effects on the power system has been analyzed according to the various operating conditions, first melting, second melting, so on. Also, the filter reducing the harmonic components have been designed and its effects on the power system have been examined.

Power Quality Impacts of an Electric Arc Furnace and Its Compensation

  • Esfandiari Ahmad;Parniani Mostafa;Mokhtari Hossein
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.153-160
    • /
    • 2006
  • This paper presents a new compensating system, which consists of a shunt active filter and passive components for mitigating voltage and current disturbances arising from an Electric Arc Furnace (EAF). A novel control strategy is presented for the shunt active filter. An extended method based on instantaneous power theory in a rotating reference frame is developed for extraction of compensating signals. Since voltages at the point of common coupling contain low frequency interharmonics, conventional methods cannot be used for dc voltage regulation. Therefore, a new method is introduced for this purpose. The passive components limit the fast variations of load currents and mitigate voltage notching at the Point of Common Coupling (PCC). A three-phase electric arc furnace model is used to show power quality improvement through reactive power and harmonic compensation by a shunt active filter using the proposed control method. The system performance is investigated by simulation, which shows improvement in power quality indices such as flicker severity index.

Developing a fault diagnosis algorithm on a high current cable of arc furnace (전기로 High Current Cable 고장진단 알고리즘 개발)

  • Choi, Seong-Jin;Jang, Yu-Jin;Kim, Sang Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.573-575
    • /
    • 2005
  • In the steel industry, a steel melting electric arc furnace is used to produce both carbon and alloy steels. Steel scrap which is charged into the furnace is heated by means of electric arc between graphite electrodes and the scrap. In this melting process, current is supplied to the furnace through HCC(high current cable) which connect the furnace and transformer. Four HCCs are assigned to each phase in our system to divide the current. Since a sudden cable breaking result in the shutdown of melting process, an aging detection of HCC is very important for both an improvement of productivity and cost reduction. In this paper, the aging of the HCC is estimated by using the current ratio between four HCCs.

  • PDF