• Title/Summary/Keyword: electric wire

Search Result 744, Processing Time 0.024 seconds

High-Speed BLDC Motor Design for Suction Fan and Impact on the Loss caused by Core Welding

  • Hong, Hyun-Seok;Kim, In-Gun;Lee, Ho-Joon;Go, Sung-Chul;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.126-133
    • /
    • 2017
  • This paper deals with the effects of welding, which is done to fix the stator stack, on a motor in case of fabricating a prototype motor that is manufactured in a small quantity. In the case of a small motor, the stator is designed and fabricated with the segmented core as a way to raise the fill factor of winding wire to the utmost within a limited size. In case of fabrication by welding both inside and outside of the stator in order to fix the segmented-core stator, the effects of stack are ignored, and the eddy current loss occurs. This paper performed the no-load test on an IPM-type BLDC motor for driving the suction fan of a vacuum cleaner, which was manufactured by using a segmented-core stator. As a result of the test, it was found that input power more than expected was supplied. To analyze the effects of welding by using the finite element analysis method and verify them experimentally, a stator was re-manufactured by bonding, and input power supplied during the no-load test was compared.

Experimental Study on the Corona Discharge Characteristics of the Pin-plate Electrode Geometries (핀이 부착된 와이어형 방전극의 형상에 따른 코로나 방전특성에 대한 연구)

  • Cheong Seongir;Lee Jaekeun;Chung Dongkyu;Ahn Youngchull
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.95-100
    • /
    • 2006
  • Electrostatic precipitators(EPs) have low pressure drop and high dust collection efficiency and are widely used for industrial dust collectors. The current-voltage characteristics, which are important to maintain high dust collection efficiency, depend on several factor: discharge electrode shape, gas flow property, dust loading etc. In this study, experiments are performed to investigate the current-voltage characteristics of the corona discharge of various electrode geometries and an empirical model is proposed to predict current-voltage characteristics of the corona discharge. The corona onset voltage correction coefficient$(\alpha)$ and the geometry correction coefficient$(k_g)$ are used to the conventional equation for wire-plate type discharge electrode. The corona onset voltages are -6.3kV and almost constant when the numbers of discharge pins are varied from 3 to 9. The length of discharge pins has very sensitive effects on the corona onset voltage. They are increased from -6.3 to -7.8kV when the discharge pin length are 8.5 and 4.5mm, respectively. The empirical model shows good agreement with experimental results and can predict the effects of discharge pin length and number.

A Study on the Properties Analysis and Estimation of Odor Detection System (향 검지 시스템의 특성 해석 및 평가에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.1-5
    • /
    • 2009
  • We studies wish to investigated establishment form of cabinet board, and confirm possibility of electrical disaster prevention through reappearance experiment of odor detection system. Established breaker consists of MCCB, RCD order in cabinet board for house, but industry is used together with. When imposed shock using shaker to terminal block that contact becomes in appropriate, flame was made sure. According to result that experiment attaching odor capsule in terminal block, capsule commissioned exactly by occurred heat. According to establishment position of sensor, difference of inspection time was about 10 seconds. Estimate odor inspection system by thing which electrical device accident prevention is available. When there is abnormal generated heat in connection of electric wire, accident prevention estimates that is possible by giving an alarm state of overheat to administrator.

Emissive Electromagnetic Field Measurement and Analysis for High Speed PLC on Medium Voltage Power-Line Channel (고속 전력선 통신을 위한 중전압 선로의 방사전자파 측정 및 분석)

  • 김선효;김상태;이영철;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.1
    • /
    • pp.54-61
    • /
    • 2003
  • This paper shows the results of emissive electromagnetic field characteristics on medium voltage power line(22.9 kV). The measurements were taken when communications signals were coupled into the 22.9 kV main wire of medium voltage power-line in a frequency range of 9 kHz to 30 MHz. The results of the measurement are as follows-emissive electromagnetic Held characteristics from multi carrier signals were superior to a single carrier signal. And we confirmed the PLC transmission distance was 1.8 km when multi-carrier transmission power was 20 dBm. Electric field strength was under the 40 dBuV/m at 30 MHz when 10 m method was measured.

An Maximization of Ionic Wind Utilizing a Cylindrical Corona Electrode (관형 코로나 방전전극을 이용한 이온풍속의 최대화)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2256-2261
    • /
    • 2010
  • A corona discharge system with needle point or wire type corona electrode has been well used as an ionic wind blower. The corona discharge system with a needle point electrode produces ions at lower applied voltage effectively. However, the corona discharge on the needle point electrode transits to the arc discharge at lower voltage, and it is hard to obtain the elevated electric field in the discharge airgap for enhancing the ion migration velocity due to the weak Coulomb force. A cylindrical corona electrode with sharp round tip is reported as one of effective corona electrode, because of its higher breakdown voltage than that of the needle electrode. A basic study, for the effectiveness of cylindrical electrode shape on the ionic wind generation, has been investigated to obtain an maximum wind velocity, which however is the final goal for the real field application of this kind ionic wind blower. In this paper, a parametric study for maximizing the ionic wind velocity utilizing the cylindrical corona electrode and a maximum ion wind velocity of 4.1 m/s were obtained, which is about 1.8 times higher than that of 2.3m/s obtained with the needle corona electrode from the velocity profile.

Design of Fuse-Link Structure & Fe-Ni Alloy Element's Shape to Increase an Interrupt Rating of a Semi-Enclosed Type Fuse (반밀폐형 퓨즈의 차단용량 상승을 위한 Fe-Ni 합금 가용체의 형상 및 퓨즈링크 구조 설계)

  • Kim, Seong-Ju;Kim, Doe-Hoon;Kang, Chang-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.5
    • /
    • pp.644-650
    • /
    • 2018
  • According to a miniaturization and integration of electric device, a little size of fuse satisfying the current carrying capacity as well as an explosive tolerance and current interrupt rating are required. Fe-Ni alloy is applied to decrease an oxidation of fuse elements. A resistance and T.C.R(temperature coefficient of resistance) of a fuse are analyzed by changing a content of Ni And full rated current I-T curve from 1A to 6.3A has been tested. In order to an explosive energy, a straight wire type is selected to reduce a fuse melting time. An interrupt rating test was conducted by changing a content of Ni and the optimal content of Ni is to be 40%.

Single cell gap polymer-stabilized blue-phase transflective LCDs using internal nanowire grid polarizer

  • Cui, Hong-Qing;Ye, Zhi-Cheng;Hu, Wei;Lin, Xiao Wen;Chung, T.C.;Jen, Tean-Sen;Lu, Yan-Qing
    • Journal of Information Display
    • /
    • v.12 no.3
    • /
    • pp.115-119
    • /
    • 2011
  • Optically isotropic liquid crystal (LC) mixture such as blue-phase LC and nanostructured LC composites exhibit the advantages of fast response time, high contrast ratio and wide-viewing angle due to the induced birefringence along the horizontal electric field. Utilizing this mixture, a novel single cell gap in-plane switching-type polymer-stabilized blue-phase transflective liquid crystal display by embedding the nanowire grid polarizer as a polarization-dependent reflective polarizer in the R region is proposed. This device can be used as a normal black mode without any quarter-wave plate or patterned in-cell phase retarder. Moreover, the transmittance is identical to the reflectance so that it will be suitable for single gamma driving. Detailed electro-optic performances, such as voltage-dependent light efficiency and viewing angle of the proposed device configuration, are investigated.

Development of Cam Die for Processing Four Lateral Switch Box (스위치 박스 4측면 가공용 캠금형 개발)

  • 김세환
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.121-125
    • /
    • 2003
  • A switch box is metal box for electric wire pipes in building. In manufacturing this box, the first press is used to mold and the second to fifth presses are used to process four-sides of a box. So four presses, four molds and four workers are needed. This leads to raise the manufacturing cost including machine lease rent, molding fee, and wages. To make matters worse, the roaring sound, vibration, and dangers of safety accidents make employees avoid from working that job. To solve this problem, a new Handling Mechanism and a cam die which combined four-die-involving processes into one die process were developed. That results job automation of the Job with one press and one die. The job avoidance problem is solved and manufacturing cost is reduced as well.

  • PDF

A Study on the Abnormal Heating of Circuit Breaker in Panel Board by Poor Connection (분전반 내 차단기의 접속불량에 의한 이상발열에 관한 연구)

  • Kim, Hyang-Kon;Kim, Dong-Woo;Choi, Hyo-Sang;Choi, Yong-Sung;Choi, Chung-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.10-14
    • /
    • 2008
  • In this paper, abnormal heating of circuit breaker in panel board by poor connection was studied. Firstly, calculation method of contact resistance shown in IEC 60943 was examined. Secondly, concerning abnormal heating of circuit breaker in panel board, field measurements were performed. Field measurements showed that locally abnormal heating by poor connection could be detected, therefore, in that case, immediate action was needed. Finally, experiments regarding abnormal heating between terminal of circuit breaker and electric wire were conducted. The results showed that abnormal heating above $180^{\circ}C$ was measured. Also, in the results of analysis of electrical waveforms according to load current, voltage drop occurred around poor connection, and the oxide was generated according to mechanical vibration. In order to prevent electrical disaster caused by poor connection, adequate torque should be applied to electrical connection, and periodic check-ups are needed.

  • PDF

Study on the Short-Circuit Electromagnetic Force Modeling for Underground Transmission Cable by Using Finite Element Method (유한요소법을 이용한 지중케이블 단락전자력 Modeling 연구)

  • Park, Hung-Sok;Kang, Ji-Won;Jang, Tae-In;Bae, Ju-Ho;Kim, Du-Jin;Choi, Kyung-Kyu;Hong, Dong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2087_2088
    • /
    • 2009
  • 최근 도심지 전력수요의 증가로 송전선로 건설의 필요성이 증대되고 있으나, 가공송전선로가 가지고 있는 한계 때문에 지중송전선로의 건설이 증대되고 있는 추세이다. 이러한 상황에서 지중 및 가공을 포함하는 거시적인 관점에서 지락 및 단락과 같은 고장시의 대전류 현상에 대한 연구는 어느 정도 시도된 바가 있으나, 지중케이블 시스템 자체에 미치는 영향에 대해서는 그 연구가 미비한 것이 현실이다. 특히 단락고장의 경우 고장전류의 크기도 크지만 고장전류 발생에 따른 전자력을 동반하게 되어 케이블 및 접속함, 각종 금구류에 전기적, 기계적인 스트레스를 야기할 수 있다. 따라서 본 논문에서는 최근 발생한 단락고장 상황을 고려하여 전자력에 의한 케이블의 거동특성을 확인하기 위해 154kV OF케이블 3상단락 실증시험을 시행하였고, 실증시험시 촬영된 고속카메라 영상을 이용한 변위분석 결과와 유한요소법을 이용하여 계산된 케이블의 변위 특성을 비교 분석하여 유한요소법을 이용한 계산방법이 케이블 거동특성 분석에 적합한지 그 실효성을 검증하고자 한다.

  • PDF