• 제목/요약/키워드: electric wire

검색결과 744건 처리시간 0.025초

와이어 가공 조건 자동 생성 2 단계 신경망 추정 (Automatic Generation of Machining Parameters of Electric Discharge Wire-Cut Using 2-Step Neuro-Estimation)

  • 이건범;주상윤;왕지남
    • 한국정밀공학회지
    • /
    • 제15권2호
    • /
    • pp.7-13
    • /
    • 1998
  • This paper presents a methodology for determining machining conditions in Electric Discharge Wire-Cut. Unification of two phase neural network approach with an automatic generation of machining parameters is designed. The first phase neural network, which is 1 to M backward-mapping neural net, produces approximate machining conditions. Using approximate conditions, all possible conditions are newly created by the proposed automatic generation procedure. The second phase neural net, which is a M to 1 forward-mapping neural net, determines the best one among the generated candidates. Simulation results with ANN are given to verify that the presenting methodology could apply for determining machining parameters in Electric Discharge Wire-Cut.

  • PDF

전철 피뢰기를 이용한 전력선 통신 데이터 전송 특성 (The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway)

  • 김재문;안승호;김양수;김철수
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.497-502
    • /
    • 2012
  • Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.

CAD/CAM 와이어 방전가공의 가공확대여유에 관한 연구 (A Study on Discharge Gap in CAD/CAM Wire Electric Discharge Machining)

  • 강상훈;박원조;배성한
    • 대한기계학회논문집
    • /
    • 제17권2호
    • /
    • pp.380-384
    • /
    • 1993
  • In precision wire electrode discharge machining by CAD/CAM, it is the most important problem on machining method to determine the wire electrode offset amout from the accurate calculation of discharge gap in order to increase the machining accuracy, after fixing the main machining conditions such as machining speed, wire tension, coolant conductivity, gap vlotage. The present study shows the relationships between discharge gap and main machining conditions by means of a series of experiment concerned with the gap using the workpiece of STD 11, and suggests the experimental eguation to calculate the accurate wire electrode offset amount under the given machining conditions for spot workers.

과전류 열화에 의해 용단된 전선의 수지상 조직 성장특성에 관한 연구 (A Study on the Growing Characteristics of Dendrite Structure of Melted Wire Deteriorated by Over Current)

  • 송길목;최충석;김동우;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1463-1465
    • /
    • 2003
  • In this paper, we studied on the growing characteristics of dendrite structure of melted wire deteriorated by over current. Electric wire was melted by Jolue's heat. By using HSIS(High Speed Imaging System), we found out a lot of melted parts of wire were dispersed and radiated. Electric wire had narrow melted areas in case of short fusing time. A lot of very small dots generated around the grain of copper cross-section and they were changed into dendrite structure. Dendrite structure appeared at the values lower than 2.5[A/sec]. In case of very short fusing time, fusing current was calculated by empirical formula. The Preece equation was not enough to analyze a variety of characteristics of melted wire because it did not consider melting time, atmosphere, etc.

  • PDF

OPGW활선 공사시 건조대 아크 예측 (Prediction to Dry-Band Arcing in Live Line Installation)

  • 김정년;김성욱;백주흠;전승익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.433-435
    • /
    • 2004
  • 본 논문에서는 기존의 가공지선(GW, Ground Wire)을 OPGW(Optical Ground Wire)로 교체공사를 할 경우 나타나는 절연로프에서의 건조대 아크현상을 수치적인 모델링를 통하여 해석할 수 있는 프로그램을 제작하고 현장조건을 입력하여 문제점을 판단하고 해결할 수 있는 방안을 제시하고자 한다.

  • PDF

핵비등에서 기포의 동특성에 대한 전기장의 효과 (Effects of an Electric Field on the Dynamic Characteristics of Bubbles in Nucleate Boiling)

  • 권영철;장근선;권정태;김무환
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.963-971
    • /
    • 2000
  • In order to investigate the effects of an electric field on EHD(Electro-hydrodynamic) nucleate boiling hat transfer characteristics in a nonuniform electric field under saturated pool boiling, the basic study has been performed experimentally. In the present study, the working fluid is R-113 and the plate-wire electrode system is used to generate a steep electric field gradient. Boiling parameters are investigated by using a high speed camera. The electric field distribution around a wire is obtained to understand the effect of an electric field on bubble departure/movement. The experimental results show EHD effects are much more considerable when the applied voltage increases. Bubbles depart away from the heated wire in radial direction. It is confirmed that the mechanisms of EHD nucleate boiling are closely connected with the dynamic behavior of bubbles. The boiling parameters are significantly changed by the electric field strength. With increasing applied voltages, the bubble size decreases and the nucleation site density, bubble velocity and bubble frequency increase.

  • PDF

와이어 하네스의 커텍터 압착공정에 대한 3차원 유한요소해석 (3D FEM simulation for connector crimping process of wire harness)

  • 구선모;윤철호;박진기;최현순;김영석
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 추계학술대회 논문집
    • /
    • pp.245-249
    • /
    • 2009
  • According to the increase of intelligent vehicles many automotive electric components are installed. The wire harness which connects those also increases. The crimping process for compressing the copper wire bundle into the terminal is a key process to assure the good quality of wire harness. For the case of inadequate forming condition many shape failures such as less-filling, over-filling are happen in the crimping process. Even though the quality of crimping shape is satisfactory the quality check for electrical resistance of wire harness is sometime not satisfied the qualification due to large variation of electrical resistance of wire harness under climate test. This large variation is thought to be related with the malfunction automotive electric system and caused by the internal stress of wire, which occurred during the crimping process. In this paper we develop the 3D-FEM simulation scheme and design methodology of optimum terminal shape. Also the effect of terminal shape on the residual stress is discussed.

  • PDF

가정용 전기매트에 대한 화재 및 감전 시험법에 관한 연구 (The Testing Methods of the Fire and the Electric Shock on the Electric Pad Using the House)

  • 장인혁;이창훈;이영주;임홍우
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권3호
    • /
    • pp.169-175
    • /
    • 2014
  • In this paper, the evaluating test methods of the fire and the electric shock on the Electric pad using the house is proposed. We analyzed electric pad using magnetic shielded type hot wire because electric pad using the magnetic shielded type hot wire generally be used in the home. We analyzed FMEA in order to analyze the mechanism of the fire and the electric shock of the electric pad and designed testing methods (Durability tests on the environment, Mechanical durability tests, Electrical durability tests) obtained through the two-step QFD and tested. We verified the evaluating test methods of the fire and the electric shock on the Electric pad using the house through the analysis of the test results.

전기장이 인가된 상태에서 폴리에틸렌으로 피복된 기울어진 전선을 통해 전파하는 화염에 대한 실험적 연구 (Experimental Study on Spreading Flame over Slanted Polyethylene Insulated Electrical Wire with AC Electric Field)

  • 임승재;김민국;박정;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.187-190
    • /
    • 2014
  • An experimental study on downwardly and upwardly spreading flames over slanted electrical wire, which is insulated by Polyethylene(PE), was conducted with applied AC electric field. The result showed that downwardly and upwardly spreading flames with angle of inclination leaned toward burnt side and unburned side, respectively. With applied AC electric fields, size of downwardly spreading flame decreased slightly and that of upwardly spreading flame increased significantly. Flame spread rate showed various trends in terms of inclination, applied voltage and frequency.

  • PDF

폴리에틸렌으로 피복된 전선을 통해 위로 전파하는 화염에 대한 교류전기장 효과에 대한 실험적 연구 (Experimental Study on Effect of AC Electric Field on Upwardly Spreading Flame over Polyethylene insulated Electrical Wire)

  • 임승재;김민국;박정;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.363-365
    • /
    • 2014
  • An experimental study on effect of AC electric field on upwardly spreading flame over electrical wire, which is insulated by Polyethylene(PE), was conducted. The result showed that upwardly spreading flame leaned toward unburned side with angle of inclination. With applied electric field, size of upwardly spreading flame increased significantly. Flame spread rate showed various trends with inclination, applied voltage and frequency.

  • PDF