• 제목/요약/키워드: electric wire

검색결과 744건 처리시간 0.024초

초고압 XLPE 케이블 금속 차폐층 고찰 (A study or Metallic sheath for Extra-high voltage XLPE cable)

  • 최창수;이갑중;정무영;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1652-1654
    • /
    • 1994
  • The Extra-high voltage XLPE cable is characterized by low transmission loss, large capacity, and high reliability. Conventionally, for XLPE cables of l54kV and above, aluminium sheath was used to be moisture barrier (thus preventing water tree deterioration of the insulation) and to protect cable core from physical stresses. However, as transmission capacity of the cable increases, so does the cable diameter and the corresponding aluminium sheath outer diameter and thickness. As a result, eddy-current loss in the sheath is increased, limiting the maximum current capacity of the cable itself. As an alternative to aluminium sheath, we have adopted stainless steel sheath with non-magnetic properties and a large resistivity, The new XLPE cable with stainless-steel sheath (CSZV cable) has drastically reduced eddy-current loss in the sheath.

  • PDF

전력/광 복합 케이블의 적용에 대한 고찰 (CONSIDERATION OF APPLICATION FOR OPTICAL COMPOSITE POWER CABLE)

  • 김종원;김학근;하보덕;이재성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1547-1549
    • /
    • 1994
  • In recent years, fiberoptic technology is becoming indispensable in establishing communication networks due to its low loss, high capacity and non-inductive properties. In the power industry as well, the technology is being required to cable and facility monitering, and control system. But, duct in the manhole and space in the culvert are required to fiberoptic cable that is separated from power cable. Therefore, some cable makers and R&D has been studying the composite fiber/power cables. This report introduces the outline of ABF system, construction and properties of optical composite power cable that used ABF technology.

  • PDF

경보음 발생 및 자동Locking 장치형 전선압축기에 대한 연구 (The study Alarm & Auto Locking System of Electric Wire Compressor)

  • 최명호;이상호;김동명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.800-802
    • /
    • 2004
  • When an accident is happen due to using a bad Wire Compressor, some public resentments are caused and It cause lawsuit for we. In case, we will undergo a colossal financial loss. in addition to, Guide to improve quality of operation by using the number of times of pressing and pressing pressure with cooperative private enterprise. And because of needs for Thermal, Electrical and Chemical factor analysis of connection point of sleeve, expect to try improving problems of wire presser whole our company. We expect that reduce fault and save cost by this process. Consequently, we will prevent power losing and black out due to line faults by expulsion of inferiority equipment and prevent heating and line fault. This is possible using Alarming and Auto Locking Wire Compressor that is improve on this study.

  • PDF

전기철도시스템에서 직격뇌에 대한 가공지선의 내뇌효과 (Shielding Effects of an Overhead Ground Wire in the Electric Railway Systems due to Direct Lightning Strokes)

  • 임성정;김재철;추동욱;정용철;창상훈
    • 조명전기설비학회논문지
    • /
    • 제15권3호
    • /
    • pp.91-96
    • /
    • 2001
  • 본 논문은 전기철도시스템 고압 배전선로에서 직격뇌에 의한 가공지선의 영향에 대해서 설명하였다. EMTP를 사용하여 가공지선과 보안기의 영향을 정량적으로 분석하였다. 또한 전차선로의 구조변경과 피격전류의 크기, 파미값의 변화에 대한 영향도 평가하였다. 분석결과 기존 시스템에 가공지선의 설치는 전기철도시스템 고압 배전선로에 유도되는 피격전압을 억제하는 효과가 있음을 입증하였다.

  • PDF

원자력 발전소용 케이블의 제특성에 관한 고찰 (Consideration of characteristic for nuclear power plant cables)

  • 김종원;안용규;박인규;백흠수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.609-611
    • /
    • 1993
  • Because the Nuclear power plant needs for the specific high stability and the confidence, it is required that cable shall be flame retardant at fire and endure to be exposed by radiation, chemical fluid, steam and high temperature at sudden accident condition and be maintained its capability on nomal operation up to 40 years as same as it's service life for Nuclear Power Plant. Consequently, In this report, we describe the terms of Environmental Qualification Test for cable and properties required for cable which developed for Nuclear Power Plant.

  • PDF

역전파 신경회로망을 이용한 가공조건에 따른 STD-11 절단면의 신뢰성 평가 (Reliability Evaluation of STD-11 Cutting Surface on the Machined Condition using the Back-Propagation Neural Network)

  • 김선진;성백섭;조규재;김하식;반제삼
    • 한국공작기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.7-15
    • /
    • 2004
  • The purpose of this study was to present the method to choose the optimum machining condition for the wire EDM. This was completed by examining the ever-changing quality of the material and by improving the function of the wire electric discharge machine. Precision metal mold products and the unmanned wire electric discharge machining system were used and then applied in industrial fields. This experiment uses the wire electric discharge machine with brass wire electrode of 0.25mm. To measure the precision of the machining surface, average values are obtained from 3 samples of measures of center-line average roughness by using a third dimension gauge and a stylus surface roughness gauge.

부식에 의한 가선재 수명특성에 관한 연구 (The Effect of Corrosion on the Fatigue Life of Catenary Wire)

  • 김용기;장세기;이덕희;정병철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.139.1-146
    • /
    • 2001
  • Contact lines are necessary to supply electric locomotives with electric power. As most railways are gradually electrified with modernized electric cars, the demand for catenary wires and their facilities are also increased. Catenary wires made by metallic materials are generally used in the open air. They are exposed to the marine area with air-borne salt or severely polluted industrial area with much corrosive emission gases depending on the railway locations. In urban area, acid rain may cause a degradation of catenary wire system. Corrosion of catenary wires can make their actual lifetime shorter than that originally designed. Thus, the messenger wires, a kind of catenary wire system, were investigated with respect to corrosion, which include new and the used one collected at the field. They are also vibrated with some amplitude everytime the train passes through the railway. The frequent cyclic load on the wire any result in a fatigue damage, Surface damage by corrosion can make fatigue crack initiate with ease. In the present study, the fatigue life of the used wire was measured 40 to 50% shorter than that of new one in average.

  • PDF

동복강선을 적용한 고속선용 조가선의 성능 및 평가 방안 (Performance and Evaluation of the Messenger Wire stranded by Copper-Clad Steel Conductors for High Speed Electric Railway)

  • 이창영;백승구;권성태;김정국;창상훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.875-880
    • /
    • 2007
  • Due to increasing demands for environment-friendly railway system, bronze wires with cadmium, which is a potential environmental hazard, have been no longer permitted as messenger wire for electric railway system. One of materials being considered as the replacements is copper-clad steel conductor(CCSC), which is currently used as contact wire for high speed operation in the Japanese shinkansen. However, there have been few studies for the application as messenger wire by the CCSC. This study deals with requirements and performances of the messenger wire stranded by the CCSC, especially for high speed electric railway. And the tentative evaluation items and methods to be specified as the Korean railway standard(KRS) are proposed.

  • PDF

Wire Rope형 진동완충장치 개발 (Development of Wire Rope Snubbers)

  • 박종범;안용호;배병홍;김민배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.334-336
    • /
    • 1999
  • Piping systems of the power generating stations have been generally protected by hydraulic and mechanical snubbers which can allow large displacements arising from temperature change while those can reduce or absorb stresses due to vibrations. However these snubbers require amounts of budget for maintenance or replacement because of the leakage, lubrication and finally short life cycle. Recently the snubbers consisted of wire rope have been proved to reduce vibrations of piping systems. While the wire rope snubbers are free of maintenance such as leakage and lubrication imported price are so high. Now it is necessary to design. manufacture and certificate these wire rope snubbers.

  • PDF

전기 철도의 전력선 통신을 위한 전차선과 조가선의 통신 특성 분석 (Analysis of Communication Characteristics on Contact wire and Messenger wire of Electric Railroad for Power Line Communication)

  • 이희준;안승호;강승욱;이종구
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.157-162
    • /
    • 2010
  • Power line communication, using 25[kV] high voltage of railway catenary, is to provide information which is real-time safety information for train operations and train workers in driving. Lots of noise were occupied in the contact wire by electrical and communication equipments. A signal attenuation was caused characteristics of the contact wire and messenger wire. For relaying communications to transmit information using the contact wire, catenary the noise and signal attenuation were investigated. And the final goal of the study was realized to transmit video information by power line communication on electric railway.