• 제목/요약/키워드: electric wire

검색결과 744건 처리시간 0.03초

High-Speed BLDC Motor Design for Suction Fan and Impact on the Loss caused by Core Welding

  • Hong, Hyun-Seok;Kim, In-Gun;Lee, Ho-Joon;Go, Sung-Chul;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.126-133
    • /
    • 2017
  • This paper deals with the effects of welding, which is done to fix the stator stack, on a motor in case of fabricating a prototype motor that is manufactured in a small quantity. In the case of a small motor, the stator is designed and fabricated with the segmented core as a way to raise the fill factor of winding wire to the utmost within a limited size. In case of fabrication by welding both inside and outside of the stator in order to fix the segmented-core stator, the effects of stack are ignored, and the eddy current loss occurs. This paper performed the no-load test on an IPM-type BLDC motor for driving the suction fan of a vacuum cleaner, which was manufactured by using a segmented-core stator. As a result of the test, it was found that input power more than expected was supplied. To analyze the effects of welding by using the finite element analysis method and verify them experimentally, a stator was re-manufactured by bonding, and input power supplied during the no-load test was compared.

핀이 부착된 와이어형 방전극의 형상에 따른 코로나 방전특성에 대한 연구 (Experimental Study on the Corona Discharge Characteristics of the Pin-plate Electrode Geometries)

  • 정성일;이재근;정동규;안영철
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.95-100
    • /
    • 2006
  • Electrostatic precipitators(EPs) have low pressure drop and high dust collection efficiency and are widely used for industrial dust collectors. The current-voltage characteristics, which are important to maintain high dust collection efficiency, depend on several factor: discharge electrode shape, gas flow property, dust loading etc. In this study, experiments are performed to investigate the current-voltage characteristics of the corona discharge of various electrode geometries and an empirical model is proposed to predict current-voltage characteristics of the corona discharge. The corona onset voltage correction coefficient$(\alpha)$ and the geometry correction coefficient$(k_g)$ are used to the conventional equation for wire-plate type discharge electrode. The corona onset voltages are -6.3kV and almost constant when the numbers of discharge pins are varied from 3 to 9. The length of discharge pins has very sensitive effects on the corona onset voltage. They are increased from -6.3 to -7.8kV when the discharge pin length are 8.5 and 4.5mm, respectively. The empirical model shows good agreement with experimental results and can predict the effects of discharge pin length and number.

향 검지 시스템의 특성 해석 및 평가에 관한 연구 (A Study on the Properties Analysis and Estimation of Odor Detection System)

  • 최충석
    • 한국화재소방학회논문지
    • /
    • 제23권2호
    • /
    • pp.1-5
    • /
    • 2009
  • 본 연구에서는 분전반의 설치 형태를 조사하였고, 향 검지 시스템의 재현 실험을 통해서 전기 재해 예방의 가능성을 확인하고자 한다. 주택용 분전반 내에 설치된 차단기는 MCCB, RCD 순서로 되어 있으나, 산업용은 혼용되고 있다. 접속이 부적절하게 된 단자대에 가진기를 이용하여 진동을 가했을 때 불꽃이 확인되었다. 단자대에 향 캡슐을 부착하여 실험한 결과, 발생한 열에 의해 캡슐이 정확하게 작동되었다. 센서의 설치 위치에 따라 검지 시간의 차이는 약 10초 이었다. 향 검지 시스템은 전기 설비 사고 예방이 가능한 것으로 판단된다. 전선의 접속부에서 이상 발열이 있을 때 과열의 상태를 관리자에게 경보해 줌으로써 사고 예방이 가능할 것으로 판단된다.

고속 전력선 통신을 위한 중전압 선로의 방사전자파 측정 및 분석 (Emissive Electromagnetic Field Measurement and Analysis for High Speed PLC on Medium Voltage Power-Line Channel)

  • 김선효;김상태;이영철;신철재
    • 한국전자파학회논문지
    • /
    • 제14권1호
    • /
    • pp.54-61
    • /
    • 2003
  • 본 논문은 중 전압 전력선(22.9 kV)에서 방사되는 전자파 특성결과를 보여주고 있다. 측정은 주파수범위 9 kHz∼30 MHz의 통신 신호를 중 전압 전력선로에 인가하였을 때 측정을 하였다. 측정결과 단일 반송신호보다 다중 반송신호에서 방사되는 전자파의 특성이 우수하며 다중반송신호의 세기가 20 dBm일 때 전력선 통신 신호는 1.8 km까지 전송 가능함을 알 수가 있었다. 전기장의 세기는 10 m 법으로 측정하였을 때 30 MHz에서 40 dBuV/m이하의 값을 볼 수가 있었다.

관형 코로나 방전전극을 이용한 이온풍속의 최대화 (An Maximization of Ionic Wind Utilizing a Cylindrical Corona Electrode)

  • 정재승;문재덕
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2256-2261
    • /
    • 2010
  • A corona discharge system with needle point or wire type corona electrode has been well used as an ionic wind blower. The corona discharge system with a needle point electrode produces ions at lower applied voltage effectively. However, the corona discharge on the needle point electrode transits to the arc discharge at lower voltage, and it is hard to obtain the elevated electric field in the discharge airgap for enhancing the ion migration velocity due to the weak Coulomb force. A cylindrical corona electrode with sharp round tip is reported as one of effective corona electrode, because of its higher breakdown voltage than that of the needle electrode. A basic study, for the effectiveness of cylindrical electrode shape on the ionic wind generation, has been investigated to obtain an maximum wind velocity, which however is the final goal for the real field application of this kind ionic wind blower. In this paper, a parametric study for maximizing the ionic wind velocity utilizing the cylindrical corona electrode and a maximum ion wind velocity of 4.1 m/s were obtained, which is about 1.8 times higher than that of 2.3m/s obtained with the needle corona electrode from the velocity profile.

반밀폐형 퓨즈의 차단용량 상승을 위한 Fe-Ni 합금 가용체의 형상 및 퓨즈링크 구조 설계 (Design of Fuse-Link Structure & Fe-Ni Alloy Element's Shape to Increase an Interrupt Rating of a Semi-Enclosed Type Fuse)

  • 김성주;김도훈;강창룡
    • 전기학회논문지
    • /
    • 제67권5호
    • /
    • pp.644-650
    • /
    • 2018
  • According to a miniaturization and integration of electric device, a little size of fuse satisfying the current carrying capacity as well as an explosive tolerance and current interrupt rating are required. Fe-Ni alloy is applied to decrease an oxidation of fuse elements. A resistance and T.C.R(temperature coefficient of resistance) of a fuse are analyzed by changing a content of Ni And full rated current I-T curve from 1A to 6.3A has been tested. In order to an explosive energy, a straight wire type is selected to reduce a fuse melting time. An interrupt rating test was conducted by changing a content of Ni and the optimal content of Ni is to be 40%.

Single cell gap polymer-stabilized blue-phase transflective LCDs using internal nanowire grid polarizer

  • Cui, Hong-Qing;Ye, Zhi-Cheng;Hu, Wei;Lin, Xiao Wen;Chung, T.C.;Jen, Tean-Sen;Lu, Yan-Qing
    • Journal of Information Display
    • /
    • 제12권3호
    • /
    • pp.115-119
    • /
    • 2011
  • Optically isotropic liquid crystal (LC) mixture such as blue-phase LC and nanostructured LC composites exhibit the advantages of fast response time, high contrast ratio and wide-viewing angle due to the induced birefringence along the horizontal electric field. Utilizing this mixture, a novel single cell gap in-plane switching-type polymer-stabilized blue-phase transflective liquid crystal display by embedding the nanowire grid polarizer as a polarization-dependent reflective polarizer in the R region is proposed. This device can be used as a normal black mode without any quarter-wave plate or patterned in-cell phase retarder. Moreover, the transmittance is identical to the reflectance so that it will be suitable for single gamma driving. Detailed electro-optic performances, such as voltage-dependent light efficiency and viewing angle of the proposed device configuration, are investigated.

스위치 박스 4측면 가공용 캠금형 개발 (Development of Cam Die for Processing Four Lateral Switch Box)

  • 김세환
    • 한국산학기술학회논문지
    • /
    • 제4권3호
    • /
    • pp.121-125
    • /
    • 2003
  • 스위치 박스는 건축물의 전선관용으로 사용되는 금속제 박스이다. 이 박스를 제조할 때는 제 1차 프레스에서 성형을 하고, 제 2차∼5차 프레스로 박스의 4측면 가공을 하게 되므로 프레스 4대, 금형 4벌, 작업자 4명을 필요로 한다. 이 때문에 기계 사용료와 금형비, 인건비 등 제조원가의 상승 요인이 되고 있으며 특히 프레스의 굉음과 진동 및 안전사고의 위험성 등으로 작업자들이 직무를 기피하고 있다. 이러한 현상을 해소하기 위하여 금형 4벌에 의한 가공을 1벌의 금형에 통합시킨 캠금형 개발과 자동이송장치를 개발하였다 그 결과, 프레스 1대와 금형 1벌로 무인화 작업을 할 수 있게 되어 직무기피요인을 해소하게 되고 제조원가 절감효과를 얻게 되었다.

  • PDF

분전반 내 차단기의 접속불량에 의한 이상발열에 관한 연구 (A Study on the Abnormal Heating of Circuit Breaker in Panel Board by Poor Connection)

  • 김향곤;김동우;최효상;최용성;최충석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.10-14
    • /
    • 2008
  • In this paper, abnormal heating of circuit breaker in panel board by poor connection was studied. Firstly, calculation method of contact resistance shown in IEC 60943 was examined. Secondly, concerning abnormal heating of circuit breaker in panel board, field measurements were performed. Field measurements showed that locally abnormal heating by poor connection could be detected, therefore, in that case, immediate action was needed. Finally, experiments regarding abnormal heating between terminal of circuit breaker and electric wire were conducted. The results showed that abnormal heating above $180^{\circ}C$ was measured. Also, in the results of analysis of electrical waveforms according to load current, voltage drop occurred around poor connection, and the oxide was generated according to mechanical vibration. In order to prevent electrical disaster caused by poor connection, adequate torque should be applied to electrical connection, and periodic check-ups are needed.

  • PDF

유한요소법을 이용한 지중케이블 단락전자력 Modeling 연구 (Study on the Short-Circuit Electromagnetic Force Modeling for Underground Transmission Cable by Using Finite Element Method)

  • 박흥석;강지원;장태인;배주호;김두진;최경규;홍동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2087_2088
    • /
    • 2009
  • 최근 도심지 전력수요의 증가로 송전선로 건설의 필요성이 증대되고 있으나, 가공송전선로가 가지고 있는 한계 때문에 지중송전선로의 건설이 증대되고 있는 추세이다. 이러한 상황에서 지중 및 가공을 포함하는 거시적인 관점에서 지락 및 단락과 같은 고장시의 대전류 현상에 대한 연구는 어느 정도 시도된 바가 있으나, 지중케이블 시스템 자체에 미치는 영향에 대해서는 그 연구가 미비한 것이 현실이다. 특히 단락고장의 경우 고장전류의 크기도 크지만 고장전류 발생에 따른 전자력을 동반하게 되어 케이블 및 접속함, 각종 금구류에 전기적, 기계적인 스트레스를 야기할 수 있다. 따라서 본 논문에서는 최근 발생한 단락고장 상황을 고려하여 전자력에 의한 케이블의 거동특성을 확인하기 위해 154kV OF케이블 3상단락 실증시험을 시행하였고, 실증시험시 촬영된 고속카메라 영상을 이용한 변위분석 결과와 유한요소법을 이용하여 계산된 케이블의 변위 특성을 비교 분석하여 유한요소법을 이용한 계산방법이 케이블 거동특성 분석에 적합한지 그 실효성을 검증하고자 한다.

  • PDF