• Title/Summary/Keyword: electric wire

Search Result 744, Processing Time 0.021 seconds

Automatic Generation of Machining Parameters of Electric Discharge Wire-Cut Using 2-Step Neuro-Estimation (와이어 가공 조건 자동 생성 2 단계 신경망 추정)

  • 이건범;주상윤;왕지남
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.2
    • /
    • pp.7-13
    • /
    • 1998
  • This paper presents a methodology for determining machining conditions in Electric Discharge Wire-Cut. Unification of two phase neural network approach with an automatic generation of machining parameters is designed. The first phase neural network, which is 1 to M backward-mapping neural net, produces approximate machining conditions. Using approximate conditions, all possible conditions are newly created by the proposed automatic generation procedure. The second phase neural net, which is a M to 1 forward-mapping neural net, determines the best one among the generated candidates. Simulation results with ANN are given to verify that the presenting methodology could apply for determining machining parameters in Electric Discharge Wire-Cut.

  • PDF

The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway (전철 피뢰기를 이용한 전력선 통신 데이터 전송 특성)

  • Kim, Jae-Moon;Ahn, Seung-Ho;Kim, Yang-Su;Kim, Chul-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.497-502
    • /
    • 2012
  • Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.

A Study on Discharge Gap in CAD/CAM Wire Electric Discharge Machining (CAD/CAM 와이어 방전가공의 가공확대여유에 관한 연구)

  • 강상훈;박원조;배성한
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.2
    • /
    • pp.380-384
    • /
    • 1993
  • In precision wire electrode discharge machining by CAD/CAM, it is the most important problem on machining method to determine the wire electrode offset amout from the accurate calculation of discharge gap in order to increase the machining accuracy, after fixing the main machining conditions such as machining speed, wire tension, coolant conductivity, gap vlotage. The present study shows the relationships between discharge gap and main machining conditions by means of a series of experiment concerned with the gap using the workpiece of STD 11, and suggests the experimental eguation to calculate the accurate wire electrode offset amount under the given machining conditions for spot workers.

A Study on the Growing Characteristics of Dendrite Structure of Melted Wire Deteriorated by Over Current (과전류 열화에 의해 용단된 전선의 수지상 조직 성장특성에 관한 연구)

  • Shong, Kil-Mok;Choi, Chung-Seog;Kim, Dong-Woo;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1463-1465
    • /
    • 2003
  • In this paper, we studied on the growing characteristics of dendrite structure of melted wire deteriorated by over current. Electric wire was melted by Jolue's heat. By using HSIS(High Speed Imaging System), we found out a lot of melted parts of wire were dispersed and radiated. Electric wire had narrow melted areas in case of short fusing time. A lot of very small dots generated around the grain of copper cross-section and they were changed into dendrite structure. Dendrite structure appeared at the values lower than 2.5[A/sec]. In case of very short fusing time, fusing current was calculated by empirical formula. The Preece equation was not enough to analyze a variety of characteristics of melted wire because it did not consider melting time, atmosphere, etc.

  • PDF

Prediction to Dry-Band Arcing in Live Line Installation (OPGW활선 공사시 건조대 아크 예측)

  • Kim J. N.;Kim S. W.;Baekm J. H.;Jeon S. I.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.433-435
    • /
    • 2004
  • 본 논문에서는 기존의 가공지선(GW, Ground Wire)을 OPGW(Optical Ground Wire)로 교체공사를 할 경우 나타나는 절연로프에서의 건조대 아크현상을 수치적인 모델링를 통하여 해석할 수 있는 프로그램을 제작하고 현장조건을 입력하여 문제점을 판단하고 해결할 수 있는 방안을 제시하고자 한다.

  • PDF

Effects of an Electric Field on the Dynamic Characteristics of Bubbles in Nucleate Boiling (핵비등에서 기포의 동특성에 대한 전기장의 효과)

  • 권영철;장근선;권정태;김무환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.963-971
    • /
    • 2000
  • In order to investigate the effects of an electric field on EHD(Electro-hydrodynamic) nucleate boiling hat transfer characteristics in a nonuniform electric field under saturated pool boiling, the basic study has been performed experimentally. In the present study, the working fluid is R-113 and the plate-wire electrode system is used to generate a steep electric field gradient. Boiling parameters are investigated by using a high speed camera. The electric field distribution around a wire is obtained to understand the effect of an electric field on bubble departure/movement. The experimental results show EHD effects are much more considerable when the applied voltage increases. Bubbles depart away from the heated wire in radial direction. It is confirmed that the mechanisms of EHD nucleate boiling are closely connected with the dynamic behavior of bubbles. The boiling parameters are significantly changed by the electric field strength. With increasing applied voltages, the bubble size decreases and the nucleation site density, bubble velocity and bubble frequency increase.

  • PDF

3D FEM simulation for connector crimping process of wire harness (와이어 하네스의 커텍터 압착공정에 대한 3차원 유한요소해석)

  • Gu, S.M.;Yin, Z.H.;Park, J.K.;Choi, H.S.;Kim, Y.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.245-249
    • /
    • 2009
  • According to the increase of intelligent vehicles many automotive electric components are installed. The wire harness which connects those also increases. The crimping process for compressing the copper wire bundle into the terminal is a key process to assure the good quality of wire harness. For the case of inadequate forming condition many shape failures such as less-filling, over-filling are happen in the crimping process. Even though the quality of crimping shape is satisfactory the quality check for electrical resistance of wire harness is sometime not satisfied the qualification due to large variation of electrical resistance of wire harness under climate test. This large variation is thought to be related with the malfunction automotive electric system and caused by the internal stress of wire, which occurred during the crimping process. In this paper we develop the 3D-FEM simulation scheme and design methodology of optimum terminal shape. Also the effect of terminal shape on the residual stress is discussed.

  • PDF

The Testing Methods of the Fire and the Electric Shock on the Electric Pad Using the House (가정용 전기매트에 대한 화재 및 감전 시험법에 관한 연구)

  • Jang, In-Hyeok;Lee, Chang-Hoon;Lee, Young-Joo;Lim, Houng-Woo
    • Journal of Applied Reliability
    • /
    • v.14 no.3
    • /
    • pp.169-175
    • /
    • 2014
  • In this paper, the evaluating test methods of the fire and the electric shock on the Electric pad using the house is proposed. We analyzed electric pad using magnetic shielded type hot wire because electric pad using the magnetic shielded type hot wire generally be used in the home. We analyzed FMEA in order to analyze the mechanism of the fire and the electric shock of the electric pad and designed testing methods (Durability tests on the environment, Mechanical durability tests, Electrical durability tests) obtained through the two-step QFD and tested. We verified the evaluating test methods of the fire and the electric shock on the Electric pad using the house through the analysis of the test results.

Experimental Study on Spreading Flame over Slanted Polyethylene Insulated Electrical Wire with AC Electric Field (전기장이 인가된 상태에서 폴리에틸렌으로 피복된 기울어진 전선을 통해 전파하는 화염에 대한 실험적 연구)

  • Lim, Seungjae;Kim, Minkuk;Park, Jeong;Chung, Sukho;Fujita, Osamu
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.187-190
    • /
    • 2014
  • An experimental study on downwardly and upwardly spreading flames over slanted electrical wire, which is insulated by Polyethylene(PE), was conducted with applied AC electric field. The result showed that downwardly and upwardly spreading flames with angle of inclination leaned toward burnt side and unburned side, respectively. With applied AC electric fields, size of downwardly spreading flame decreased slightly and that of upwardly spreading flame increased significantly. Flame spread rate showed various trends in terms of inclination, applied voltage and frequency.

  • PDF

Experimental Study on Effect of AC Electric Field on Upwardly Spreading Flame over Polyethylene insulated Electrical Wire (폴리에틸렌으로 피복된 전선을 통해 위로 전파하는 화염에 대한 교류전기장 효과에 대한 실험적 연구)

  • Lim, Seungjae;Kim, Minkuk;Park, Jeong;Chung, Sukho;Fujita, Osamu
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.363-365
    • /
    • 2014
  • An experimental study on effect of AC electric field on upwardly spreading flame over electrical wire, which is insulated by Polyethylene(PE), was conducted. The result showed that upwardly spreading flame leaned toward unburned side with angle of inclination. With applied electric field, size of upwardly spreading flame increased significantly. Flame spread rate showed various trends with inclination, applied voltage and frequency.

  • PDF