• Title/Summary/Keyword: electric volume resistivity

Search Result 37, Processing Time 0.02 seconds

The investigation of forming the n+ emitter layer for crystalline silicon solar cells (결정질 실리콘 태양전지의 n+ emitter층 형성에 관한 특성연구)

  • Kwon, Hyuk-Yong;Lee, Jae-Doo;Kim, Min-Jung;Lee, Soo-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.233-233
    • /
    • 2010
  • It is important to form the n+ emitter layer for generating electric potential collecting EHP(Electron-Hole Pair). In this paper the formation on the n+ emitter layer of silicon wafer has been made with respect to uniformity of shallow diffusion from a liquid source. The starting material was crystalline silicon wafers of resistivity $0.5{\sim}3\{Omega}{\cdot}cm$, p-type, thickness $200{\mu}m$, direction[100]. The formation of n+ emitter layer from the liquid $POCl_3$ source was carried out for $890^{\circ}C$ in an ambient of $N_2:O_2$::10:1 by volume. And than each conditions are pre-deposition and drive-in time. It has been made uniformity of at least. so, the average of sheet resistance was about 0.12%. In this study, sheet resistance was measured by 4-point prove.

  • PDF

Breakdown Strength Estimation of Non-Cellulosic Insulating Materials Used in Electrical Power Equipment

  • Singh, Sakshi;Mohsin, Mirza Mohd.;Masood, Aejaz
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.6
    • /
    • pp.338-340
    • /
    • 2017
  • Breakdown of solid insulating materials in power equipment could result in undesired outages and replacements, and may be due to an increase in electric stress on the material. Therefore, it is necessary to conduct a proper diagnosis of materials before their practical use. In this work, a few inherent properties of different non-cellulosic insulating materials, such as Nomex, Teflon, laminated Nomex, glass bonded mica, epoxy resin bonded mica paper, and epoxy resin bonded fiberglass, have been evaluated by performing non-destructive dielectric diagnostic measurements, and an attempt has been made to correlate these basic parameters to evaluate the breakdown strength (BDS). An equation has been proposed using a basic theory which defines the correlation between the BDS, dielectric constant, dissipation factor, sample thickness, and volume resistivity. The results obtained from the equation are also compared with the experimental values. The suggested equation will be helpful to predict the BDS of any non-cellulosic material without experimentation in the laboratory.

Effects of Freshwater Flooding on Properties of CSPE with Number of Dried-Days (건조일수에 따른 CSPE의 특성에 미치는 담수침지의 영향)

  • Kang, Myeong-Kyun;Lee, Jung-Hoon;Lee, Seung-Hoon;Jeon, Jun-Soo;Park, Young;Park, Ki-Yub;Jeong, Kyu-Won;Shin, Yong-Deok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.8
    • /
    • pp.597-601
    • /
    • 2013
  • The accelerated thermal aging of a CSPE were carried out for 0, 80.82, 161.63 days at $100^{\circ}C$, which are equal to 0, 40 and 80 years of aging at $50^{\circ}C$, respectively. The volume electrical resistivities of the seawater and freshwater flooding were measured through 3-terminal circuit diagram. The volume electrical resistivities of the 0y, 40y and 80y were $2.454{\times}10^{13}{\sim}1.377{\times}10^{14}{\Omega}{\cdot}cm$, $1.121{\times}10^{13}{\sim}7.529{\times}10^{13}{\Omega}{\cdot}cm$ and $1.284{\times}10^{13}{\sim}8.974{\times}10^{13}{\Omega}{\cdot}cm$ at room temperature, respectively. The dielectric constant of the 0y, 40y and 80y were 2.922~3.431, 2.613~3.285 and 2.921~3.332 at room temperature, respectively. It is certain that the ionic ($Na^+$, $Cl^-$, $Mg^{2+}$, ${SO_4}^{2-}$, $Ca^{2+}$, $K^+$) conduction current was formed by the salinity of the seawater. The volume electrical resistivity of the cleaned CSPE via freshwater trends slightly upward with the number of dried days at room temperature. As a result, the $CH_2$ component of thermally accelerated aged CSPE decreased after seawater and freshwater flooding for 5 days respectively, whereas the atoms such as Cl, O, Pb, Al, Si, Sb, S related with the conducting ion ($Na^+$, $Cl^-$, $Mg^{2+}$, ${SO_4}^{2-}$, $Ca^{2+}$, $K^+$) component increased relatively.

A Study on the Properties of CSPE According to Accelerated Thermal Aging Years

  • Lee, Jung-Hoon;Kang, Myeong-Kyun;Jeon, Jun-Soo;Lee, Seung-Hoon;Kim, In-Yong;Park, Hyun-Shin;Shin, Yong-Deok
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.643-648
    • /
    • 2014
  • The accelerated thermal aging of CSPE (chlorosulfonated polyethylene) was carried out for 40.41, 121.22, and 202.04 days at $100^{\circ}C$, which are equivalent to 20, 60, and 100years of aging at $50^{\circ}C$, respectively. The volume electrical resistivities of the accelerated thermally aged CSPE samples for 0, 40.41, 121.22, and 202.04 days were $1.107{\times}10^{14}-2.097{\times}10^{14}$, $7.752{\times}10^{13}-1.556{\times}10^{14}$, $7.693{\times}10^{13}-1.521{\times}10^{14}$, and $7.380{\times}10^{13}-1.304{\times}10^{14}{\Omega}{\cdot}cm$, respectively, at room temperature. The permittivities of the accelerated thermally aged CSPE samples for 0, 40.41, 121.22, and 202.04 days were $2.89{\times}10^{-11}-3.65{\times}10^{-11}$, $3.40{\times}10^{-11}-3.70{\times}10^{-11}$, $3.50{\times}10^{-11}-3.82{\times}10^{-11}$, and $3.76{\times}10^{-11}-4.13{\times}10^{-11}$ F/m, respectively, at room temperature. The EAB (elongation at break) of the accelerated thermally aged CSPE samples for 0, 40.41, 121.22, and 202.04 days were 98.8-101.3, 59.5-60.3, 37.8-39.2, and 41.8-44.3%, respectively, at room temperature. The apparent densities of the accelerated thermally aged CSPE samples for 0, 40.41, 121.22, and 202.04 days were 1.603-1.614, 1.611-1.613, 1.622-1.628, and $1.618-1.620g/cm^3$, respectively, at room temperature. The measured currents of the accelerated thermally aged CSPE and the standard sample were almost constant after 5 min of applying a 300-V/mm electric field to the CSPE. The V-I slope of the accelerated thermally aged CSPE sample was increased if the applied electric field was increased at room temperature, and the V-I slope of the accelerated thermally aged CSPE was higher than that of standard CSPE.

Effects of Freshwater Flooding on the Properties of the Accelerated Thermally Aged CSPE (가속열화 된 CSPE의 특성에 미치는 담수침지의 영향)

  • Kang, Myeong-Gyun;Lee, Jung-Hoon;Lee, Seung-Hoon;Jeon, Jun-Soo;Kim, In-Yong;Shin, Yong-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.367-370
    • /
    • 2014
  • The accelerated thermal aging of a CSPE were carried out for 0, 80.82, 161.63 days at $100^{\circ}C$, which are equal to 0, 40 and 80 years, respectively. The volume electrical resistivities of the non-accelerated thermally aged CSPE and the accelerated thermally aged CSPE for 40y and 80y were $9.620{\times}10^{12}{\sim}1.246{\times}10^{13}{\Omega}{\cdot}cm$, $5.066{\times}10^{12}{\sim}7.576{\times}10^{12}{\Omega}{\cdot}cm$ and $7.195{\times}10^{12}{\sim}9.208{\times}10^{12}{\Omega}{\cdot}cm$ at room temperature, respectively. The dielectric constant of the non-accelerated thermally aged CSPE and the accelerated thermally aged CSPE for 40y and 80y were 3.355~4.030, 2.996~3.963 and 3.020~4.776 at room temperature, respectively. After seawater and freshwater flooding, the volume electrical resistivity of the CSPE trend slightly upward according to drying day at room temperature. After seawater flooding, the dielectric constant of the accelerated thermally aged CSPE were not measured. After seawater flooding, bright open pores of the accelerated thermally aged CSPE were partly transferred to dark close pores due to salinity. After freshwater flooding, dark close pores of the accelerated thermally aged CSPE were partly transferred to bright open pores because salinity of them is decreased. An insulation property of a cable in NPPs was decreased because of the seawater flooding, and an insulation property of them was recovered through the freshwater flooding. As a result, it is considered that an insulation property of a contaminated cable through Tsunami can be recovered if it is cleaned quickly.

A Study on Electrodeionization for Purification of Primary Coolant of a Nuclear Power Plant (원자력 발전소의 일차 냉각수 정화를 위한 전기탈이온법의 기초연구)

  • Yeon, Kyeong-Ho;Moon, Seung-Hyeon;Jeong, Cheorl-Young;Seo, One-Sun;Chong, Sung-Tai
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.73-86
    • /
    • 1999
  • The ion-exchange method for the purification of primary coolant has been used broadly in PWR(pressurized water reactor)-type nuclear power plants due to its high decontamination efficiency, simple system, and easy operation. However, its non-selective removal of metal and non-radionuclides shortens its life, resulting in the generation of a large amount of waste ion-exchange resin. In this study, the feasibility of electrodeionization (EDI) was investigated for the purification of primary cooling water using synthetic solutions under various experimental conditions as an alternative method for the ion exchange. The results shows that as the feed flow-rate increased, the removal efficiency increased and the power consumption decreased. The removal rate was observed as a 1000 decontamination factor(DF) at a nearly constant level. For the synthetic solution of 3 ppm TDS (Total Dissolved Solid), the power consumption was 40.3 mWh/L at 2.0 L/min of feed flow rate. The higher removal rate of metal species and lower power consumption were obtained with greater resin volume per diluting compartment. However, the flow rate of the EDI process decreased with the elapsed time because of the hydrodynamic resistivity of resin itself and resin fouling by suspended solids. Thus, the ion-exchange resin was replaced by an ion-conducting spacer in order to overcome the drawback. The system equipped with the ion-conducting spacer resolved the problem of the decreasing flow rate but showed a lower efficiency in terms of the power consumption, the removal rate of metal species and current efficiency. In the repeated batch operation, it was found that the removal efficiency of metal species was stably maintained at DF 1000.

  • PDF

Application of the Electrical Impedance of Rocks in Characterizing Pore Geometry (암석 내 공극구조의 평가를 위한 전기임피던스의 적용)

  • Choo, Min-Kyoung;Song, In-Sun;Lee, Hi-Kweon;Kim, Tae-Hee;Chang, Chan-Dong
    • The Journal of Engineering Geology
    • /
    • v.21 no.4
    • /
    • pp.323-336
    • /
    • 2011
  • The hydro-mechanical behavior of the Earth's crust is strongly dependent on the fractional volume and geometrical structure of effective pore spaces. This study aims to understand the characteristics of pores using electrical impedance. We measured the electric impedance of core samples (diameter, 38-50 mm; length, 70-100 mm) of three types of granite (Hwangdeung, Pocheon, and Yangsan) and two types of sandstone (Boryung and Berea) with different porosities and pore structures, after saturation with saline water of varying salinities. The results show that resistance decreases but capacitance increases with increasing salinity of the pore fluid. For a given salinity, the resistivity and formation factor are reduced with increasing porosity of the rocks, and the capacitance increases. Berea sandstone shows anisotropy in resistance, tortuosity, and cementation factor, with these factors being highest normal to bedding planes. This result indicates that the connectivity of pores is weakest normal to bedding. In conclusion, the electrical characteristics of the tested samples are related not only to their porosity but also to the pore geometry.