• Title/Summary/Keyword: electric survey

Search Result 436, Processing Time 0.031 seconds

Investigation and Analysis of Interruption Characteristics for Industrial Customers

  • Choi, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.45-52
    • /
    • 2007
  • Electric power is an important element in any modern economy. The availability of a reliable power supply at a reasonable cost is important for the economic growth and development of a country. Electric power utilities throughout the world therefore strive to meet customer demands economically with high quality and reliability. As the power industry moves towards open competition, therefore, there has been a call for a methodology by which to evaluate power system reliability through the use of customer interruption characteristics. This paper presents the results of an investigation and analysis of interruption characteristics of an industrial customer in Korea. This study used a direct visit survey to determine the investigation and analysis of electric service quality and the characteristics of industrial customers in Korea. A customer survey conducted throughout Korea via personal interviews of 660 sample customers is presented here. Variation according to characteristics of interruption such as duration, time of day, frequency and day of interruption was also investigated

Basic Study for Selection of Factors Constituents of User Satisfaction for Micro Electric Vehicles (초소형전기차 사용자만족도 구성요인 선정을 위한 기반연구)

  • Jin, Eunju;Seo, Imki;Kim, Jongmin;Park, Jejin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.581-589
    • /
    • 2021
  • With the recent increase in the introduction of micro-electric vehicles in Korea, interest in micro-electric vehicle user satisfaction is increasing to revitalize related markets. In this paper, a basic study was conducted on the development of public services using micro-electric vehicle based on the constituent factors of user satisfaction. The survey includes: ① 'Analytic Hierarchy Process (AHP) for selecting the priority factors of user satisfaction of micro-electric vehicles', ② 'A survey of micro-electric vehicles image' to collect data in advance for providing users' preferences and transportation services for micro-electric vehicles, ③ In order to investigate the user satisfaction level of users who actually operated micro-electric vehicles, the order of 'user satisfaction survey of micro-electric vehicle drivers' was conducted. In the Analytic Hierarchy Process (AHP) analysis, it was found that users regarded as important in the order of 'user utilization data', 'vehicle movement data', and 'charging service data'. In the micro-electric vehicle image survey, users perceived micro-electric vehicles more positively in terms of "safety", 'durability', 'Ride comfort', 'design', 'MOOE (Maintenance and other operating expense)', and 'environment-friendly' when comparing micro-electric vehicles with electric motorcycles. In the survey on the user satisfaction of micro-electric vehicle drivers, the use of micro-electric vehicle did not directly affect work performance efficiency, and there was an experience of being disadvantaged on the road due to the size of the micro-electric vehicle, and driving in a cluster of micro-electric vehicle for outdoor advertisements. The city's public relations effect was great, but it was concerned about safety. In the future, based on the results of this study, we plan to build a user satisfaction structural equation model, preemptively discover feedback R&D for micro-electric vehicle utilization services in the public field, and actively seek to discover new public mobility support services.

The Study on the Actual Condition about Facility Accident Case and PL Recognition of the Safety Manager in Electric Installation for Private Use (수용가 전기설비 관리자의 PL인식 및 설비사고사례에 관한 실태연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Jung, Jong-Wook;Jung, Jin-Su;Kim, Sun-Gu;Lee, Jun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.309-312
    • /
    • 2008
  • In this paper, we investigated electric safety manager's PL recognition and accident occurrence of electric power facilities(power cable, transformer, circuit breaker) in electric installation for private use. The target of questionnaire survey is 450 electric installations for private use, 154 responded the questionnaire among these and it occupied 35.8%. Most of receiving voltage were 22.900kV. The questionnaire survey says that 58% of electric safety manager knew well about PL contents and 42% of them did not recognize about PL contents, About the PL application of electrical facility accidents, 82.4% of them must applied PL law, 5.8% of them did not need the PL law. Reason of PL application occupied 64% for stability of electrical facility and product, 19% for prevention of same accident. The accident of transformer occupied most and the power cable accident were much next. The questionnaire survey results, electric safety managers are interested in PL content. thev expected necessity of PL application about electrical accident strongly.

  • PDF

Geophysical exploration for the Site Charcteristics of Iljumun Gate in Hwanseongsa Temple (지구물리탐사를 이용한 경산시 환성사 일주문 지반조사)

  • Kim, Ki-Hyun;Suh, Man-Cheol
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.131-136
    • /
    • 2008
  • We performed a non-destructive geophysical survey such as an elastic wave survey, electric specific resistance survey, plate loading test, etc. in order to grasp the structure and status of the ground around the pillar gate and to provide the directions and design data for preservation and maintenance during reconstruction. The result of electric specific resistance survey shows 50-1300 ohm-m range of general electric specific resistance distribution. Besides, the positions around 1m south of stone pillars, between stone pillar No.3 and 4, and 1m north of stone pillar No.2 and 3 show abnormality of relatively lower electric specific resistance than their surroundings. The abnormality of low electric specific resistance appearing between stone pillar No.3 and 4 shows consistency with the abnormal section appearing from the result of elastic wave reflection survey. The result of a plate loading test shows that allowable bearing force is over $10.70tf/m^2$, and the settlement amount at this time was calculated as 19.635mm. The design load during reconstruction of pillar gates was calculated as $16.37t/m^2$ by applying assumption values, which is far more than the allowable bearing force, so it is judged that a measure to strengthen the foundation ground is necessary.

  • PDF

A Study on the Program for Estimation of Electric Rates and the Analysis for Power Consumption in Complex Consumer (복합다용도 수용가의 전력소비특성 분석 및 전기요금 산정프로그램 개발)

  • Kim, Se-Dong;Yoo, Sang-Bong;Ki, Yoo-Kyung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.103-107
    • /
    • 2014
  • Together with housings, general buildings and industrial facilities, multi-purpose complexes are equipped with various and special equipment. They are often used by many unspecified people, which causes an increase in annual electricity consumption. Because of this, a great amount of money has been spent for electric charge, far more in excess of the budget, so a reasonable electricity rate needs to be estimated. In this study, we surveyed the power consumption, average power use, and annual electricity bill of multi-purpose complexes in the past five years. To see the general tendency of the survey, we conducted a statistical analysis with such parameters as average, maximum, and minimum values. Through regression analysis, we could see the trend of the survey in linear way. Based on the survey, we have developed an electric-rate calculation program to estimate the next year's budget on electricity.

A Survey on the Reaction of Medium and Small Electric Power Industries Under Deregulatory Reforms of Electric Power Industry (전력산업 구조개편에 따른 중소전력산업체 대응의식에 관한 조사연구)

  • Kim, Young-Gil;Cho, Ki-Seon;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.51-55
    • /
    • 2001
  • This paper presents the result or a survey and analysis on the reaction of medium and small electric power industries under deregulatory reforms of electric power industry. To achieve the deregulatory reforms smoothly, the strategy that minimize side effects in a transient period and form full national if sympathy, are required. A mailed questionnaire, in this paper, had of been achieved objectively to seize the tend. According to the result of this paper, the deregulatory reforms should be managed to be carefully and publicized continuously through various medium. The result of this paper can be utilized to perform effectively the deregulatory reforms.

  • PDF

A survey of the optimal ventilation rate and the permissible CO2 concentration in the saloon (전동차 실내의 적정 환기율 및 이산화탄소 농도 기준치에 관한 고찰)

  • Cho Yong-Sung;Kang Seok-Teak;Park Young-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.312-317
    • /
    • 2005
  • Electric Multiple Unit is one of the major mass public transportation systems and passengers are under the influence of indoor air quality such as air temperature, relative humidity and concentration of CO2 gas. Therefore ventilation system of Electric Multiple Unit should be designed for both healthy and comfortable environments. We survey the optimal ventilation rate and the permissible CO2 concentration in the saloon with the consideration of the cooling and heating capacity and fresh air induced from tunnel.

  • PDF

The Signal Distortion Due to the Electromagnetic Induction Inside a Cable (전선의 전자기유도 현상에 의한 신호 왜곡)

  • Jeong Ji-Min;Choi Seong-Jun;Kim Jung-Ho;Song Young-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.4
    • /
    • pp.251-255
    • /
    • 2004
  • Electric cables such as multi-interphone cables and ribbon cab]os are commonly used for data aquisition in the DC resistivity survey. In general, electromagnetic induction may occur in the electric cables when electric current flows through them. In case of using multi-interphone cables in the DC resistivity survey, electromagnetic induction could take place due to the entangled wires of the multi-interphone cables, when the current flows through them. Then, the electromagnetic induction may cause measured DC resistivity data to be distorted. In this study, a monitoring system with PXI (PCI Extention for Instrumentation) was constructed to examine signal distortion on the DC resistivity data, attributed to the electromagnetic induction. Common electric cables used in the DC resistivity survey were tested to observe the waveforms of the electric voltages. The waveforms measured were compared to examine signal distortion due to the electromagnetic induction. The results may provide information on the resistivity data obtained using different electric cables in the DC resistivity survey. The distortion of waveforms attributed to the electromagnetic induction wat not observed when using ribbon cables for DC resistivity data aquisition, while the distortion were observed when using multi-interphone. Therefore, the ribbon cables provide better quality of data than other cables in the DC resistivity data aquisition.