• 제목/요약/키워드: electric state

검색결과 1,769건 처리시간 0.036초

Single Line-to-ground Fault Location and Information Modeling Based on the Interaction between Intelligent Distribution Equipment

  • Wang, Lei;Luo, Wei;Weng, Liangjie;Hu, Yongbo;Li, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1807-1813
    • /
    • 2018
  • In this paper, the fault line selection and location problems of single line-to-ground (SLG) fault in distribution network are addressed. Firstly, the adaptive filtering property for empirical mode decomposition is formulated. Then in view of the different characteristics showed by the intrinsic mode functions(IMF) under different fault inception angles obtained by empirical mode decomposition, the sign of peak value about the low-frequency IMF and the capacitance transient energy is chosen as the fault line selection criteria according to the different proportion occupied by the low-frequency components. Finally, the fault location is determined based upon the comparison result with adjacent fault passage indicators' (FPI) waveform on the strength of the interaction between the distribution terminal unit(DTU) and the FPI. Moreover, the logic nodes regarding to fault line selection and location are newly expanded according to IEC61850, which also provides reference to acquaint the DTU or FPI's function and monitoring. The simulation results validate the effectiveness of the proposed fault line selection and location methods.

A QEE-Oriented Fair Power Allocation for Two-tier Heterogeneous Networks

  • Ji, Shiyu;Tang, Liangrui;He, Yanhua;Li, Shuxian;Du, Shimo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권5호
    • /
    • pp.1912-1931
    • /
    • 2018
  • In future wireless network, user experience and energy efficiency will play more and more important roles in the communication systems compared to their roles at present. Quality of experience (QoE) and Energy Efficiency (EE) become the widely used metrics. In this paper, we study a combinatorial problem of QoE and EE and investigate a fair power allocation in heterogeneous networks. We first design a new metric, QoE-aware EE (QEE) to reflect the relationship of QoE and energy. Then, the concept of Utopia QEE is introduced, which is defined as the achievable maximum QEE in ideal conditions, for each user. Finally, we transform the power allocation process to an optimization of ratio of QEE and Utopia QEE and use invasive weed optimization (IWO) algorithm to solve the optimization problem. Numerical simulation results indicate that the proposed algorithm can get converged and efficiently improve the system energy efficiency and the QoE for each user.

MPC-based Two-stage Rolling Power Dispatch Approach for Wind-integrated Power System

  • Zhai, Junyi;Zhou, Ming;Dong, Shengxiao;Li, Gengyin;Ren, Jianwen
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.648-658
    • /
    • 2018
  • Regarding the fact that wind power forecast accuracy is gradually improved as time is approaching, this paper proposes a two-stage rolling dispatch approach based on model predictive control (MPC), which contains an intra-day rolling optimal scheme and a real-time rolling base point tracing scheme. The scheduled output of the intra-day rolling scheme is set as the reference output, and the real-time rolling scheme is based on MPC which includes the leading rolling optimization and lagging feedback correction strategy. On the basis of the latest measured thermal unit output feedback, the closed-loop optimization is formed to correct the power deviation timely, making the unit output smoother, thus reducing the costs of power adjustment and promoting wind power accommodation. We adopt chance constraint to describe forecasts uncertainty. Then for reflecting the increasing prediction precision as well as the power dispatcher's rising expected satisfaction degree with reliable system operation, we set the confidence level of reserve constraints at different timescales as the incremental vector. The expectation of up/down reserve shortage is proposed to assess the adequacy of the upward/downward reserve. The studies executed on the modified IEEE RTS system demonstrate the effectiveness of the proposed approach.

Three-dimensional numerical parametric study of deformation mechanisms of grouped piled raft foundation due to horizontal loading

  • Bo Wang;Houkun Cui;Yan Li;Ya Dai;Nan Zhang
    • Geomechanics and Engineering
    • /
    • 제35권6호
    • /
    • pp.617-626
    • /
    • 2023
  • In this study, three-dimensional numerical parametric study was conducted to explore deformation mechanisms of grouped piled-raft-foundation due to lateral load in clays. Effects of load intensity, loading angle, soil stiffness, pile diameter, pile spacing and pile length on foundation deformations were explored. It is found that the smallest and largest movements of pile foundation are induced when the loading angles are 0° and 30°~60°, respectively. By increasing loading angle from 0° to 30°~60°, the resultant horizontal movements and settlements increase by up to 20.0% and 57.1%, respectively. Since connection beams can substantially increase integrity of four piled raft foundation, resultant horizontal movements, settlements and bending moments induced in the piled raft foundation decrease by up to 54.0%, 8.8% and 46.3%, respectively. By increasing soil stiffness five times, resultant horizontal movements and settlements of pile foundation decrease by up to 61.7% and 13.0%, respectively. It is indicated that effects of connection beam and soil stiffness on settlements of pile foundation are relatively small. When pile diameter is less than 1.4 m, deformations of piled raft foundation decrease substantially as a reduction in the pile diameter. Two dimensional groups are proposed to develop calculation charts of horizontal movements and settlements of pile foundation. The proposed calculation charts can directly estimate movements of piled raft foundation under arbitrary loading, ground and pile conditions.

Application of a Pulse Electric Field to Cross-flow Ultrafiltration of Protein Solution

  • Kim, Hyong-Ryul;Lee, Kisay
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제4권1호
    • /
    • pp.46-50
    • /
    • 1999
  • The application of pulsed electric field was investigated in the crossflow ultrafiltration of BSA (bovine serum albumn) to economize the application time of electric current as well as to avoid inherent problems of long-term application of electric field. During the application of various cyclic patterns of pulsed electric current, the averaged filtration flowrate and the degree of concentration were maintained higher than those obtained in the absence of electric current application. The temperature increase, pH change, and BSA loss by electrodeposition were all negligible during the operation. The averaged filtration flowrate increased as the ON/OFF duration ratio of electric current was higher and as the period of ON/OFF cycle was shorter. The re-establishment of concentration polarization was dependent to the duration of current OFF state and, therefore, a longer duration of OFF state was not favorable in maintaining higher filtration flow rate. Although the averaged filtration flowrate was enhanced as the magnitude of electric current increased, the flowrate enhancement became smaller as the magnitude of current value above which the degree of electrokinetic depolarization is no further improved.

  • PDF

Dual-model Predictive Direct Power Control for Grid-connected Three-level Converter Systems

  • Hu, Bihua;Kang, Longyun;Feng, Teng;Wang, Shubiao;Cheng, Jiancai;Zhang, Zhi
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1448-1457
    • /
    • 2018
  • Many researchers devote themselves to develop model-predictive direct power control (MPDPC) so as to accelerate the response speed of the grid-connected systems, but they are troubled its large computing amount. On the basis of MPDPC, dual MPDPC (DMPDPC) is presented in this paper. The proposed algorithm divides the conventional MPDPC into two steps. In the first step, the optimal sector is obtained, which contains the optimal switching state in three-level converters. In the second step, the optimal switching state in the selected sector is searched to trace reference active and reactive power and balance neutral point voltage. Simulation and experiment results show that the proposed algorithm not only decreases the computational amount remarkably but also improves the steady-state performance. The dynamic response of the DMPDPC is as fast as that of the MPDPC.

WLAV 상태추정에 의한 전력계통 파라미터 에러 추정에 관한 연구 (Identification of Parameter Errors in Electric Power Systems by WLAV State Estimation)

  • 김홍래;권형석;김동준
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권9호
    • /
    • pp.451-458
    • /
    • 2000
  • This paper addresses the issues of the parameter error detection and identification in electric power systems. In this paper, the parameter error identification and estimation is carried out as part of the state estimation. A two stage estimation procedure is used to detect and identify the parameter errors. The suspected parameters are identified by the WLAV state estimator as the first stage. A new WLAV state estimator adding the suspected system parameters in the state vector is used to estimate the exact value of parameter errors. Supporting examples are given by using IEEE 14 bus system.

  • PDF

Microwave Heating and Pre-sintering of Copper Powder Metal Compacts in Separated Electric and Magnetic Fields

  • Zimmerman, Darin T.;Johnson, Earnie J.;Ma, JunKun;Miskovsky, Nicholas M.;Weisel, Gary J.;Weiss, Brock L.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.266-267
    • /
    • 2006
  • We present a systematic study of the heating and pre-sintering behavior of porous copper powder metal compacts. We employ a TE102 single mode microwave system to position the samples in the separated electric field (E) or magnetic field (H) anti-node of the cavity. We observe significant differences in the heating, pre-sintering, and microstructure evolution of the samples due to the individual fields. We note that sample history (whether heated first in the E-field or H-field) greatly effects a difference in heating trends and subsequent heating behavior and does not appear to be solely a thermal process.

  • PDF

지중송전선로와 병행하는 기설통신선의 유도전압 분석 (Analysis of Induced Voltage in Parallel Telecommunication Cables from Underground Power Cables)

  • 임광식;장우석;한창석;홍동석;유진선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.523-524
    • /
    • 2011
  • This paper covers induced voltage in parallel telecommunication cable with underground power cable to be linked between substations. The simulation was carried out the induced voltage in telecommunication cable according to the transposition of power cables and fault location for various conditions. This study based on the EMTP/ATPDraw with actual underground cable systems while the power cables are in steady state and transient state.

  • PDF

On Electric Field Induced Processes in Ionic Compounds

  • Schmalzried, H.
    • 한국세라믹학회지
    • /
    • 제38권6호
    • /
    • pp.499-505
    • /
    • 2001
  • The behaviour of ionic compound crystals under combined chemical and externally applied electrical potential gradients is discussed. Firstly, a systematic overview is given. Then a formal analysis follows. The transport equations of the ions and the electric defects predict that even with reversible electrodes demixing, and in particular decomposition of the compound will occur if the applied d.c. current density is sufficiently high. These predictions are illustrated by appropriate experiments. With the help of the solid solution (Me, Fe)O, where Fe-ions are the dilute species, we investigate experimentally the behaviour of a ternary ionic crystal under a d.c. electric current load. All the compounds were placed in a galvanic cell, and the internal reactions which then could be observed were driven by the electric field in this cell. In addition, we discuss the influence of the electric field on the classical solid state reaction AX+BX=ABX$_2$, if again the reaction couple is placed in a galvanic cell.

  • PDF