• Title/Summary/Keyword: electric shock accident

Search Result 51, Processing Time 0.021 seconds

Grounding method for Improving of the Characteristics on Cable TV Transmission Line (케이블 TV 전송선로의 특성 개선을 위한 접지방식)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Yeon, Che-Chin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.37-40
    • /
    • 2002
  • Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in cable TV.

  • PDF

Analisys about the Earth Fault Characteristics in the Wireless Power Transmission System of the Electric Vehicle (무선충전 전기자동차 전력공급장치에서의 지락사고 특성 분석)

  • Jung, Jin-Soo;Han, Woon-Ki;Park, Chan-Um;Song, Young-Sang;Lim, Hyun-Sung;Cho, Min-Ho;Lyu, Ji-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.13-17
    • /
    • 2014
  • In this paper, the risk of electric shock is analyzed through analysis for characterization of potential distribution analysis and ground fault current analysis near the area where there are occurred a ground fault at electric vehicle wireless charging system using 20kHz. Studies for electric vehicle wireless charging system are in the works for development of efficiency increase, pickup shape design and communication module as a fundamental research step. But the research related to electrical safety and is still scarce state so that more studies are necessary to commercialize. As a result of analysis, it is verified that induced voltage is arisen more up to 45V near the a area of accident during ground fault and fault current has been maintained continuously without clearing fault condition by operating characteristics for circuit breaker and inverter.

A Study on ground fault at low voltage line and apparatus in urban railway station (도시철도역사의 저압선로 및 기기에서의 지락사고 방지 방안에 관한 검토)

  • Min Kyung-Yun;Kim Jin-Ho;Han Hag-Su
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.699-704
    • /
    • 2005
  • In the station of the railway and the subway various illumination equipment and a general power equipment for a passenger convenience, the signal equipment and the communication equipment which is necessary to the train operation provided. At the all of like this equipment from the electric room which is established in each station by changing from high voltage to low voltage and it supplies from the illumination transformer, the power transformer and the signal transformer. If it supplies to the equipment from the high voltage to the low voltage, it must be established to contact protection device in between the high voltage coil and the low voltage coil. Also it must do the grounding faulting device at the low voltage lines, the earthing devices at apparatus for the protection of an electric shock and an electric fire by the electric relation law. Compared the related regulations between the facilities which require protective functions such as grounding fault or earthing in public utilities like subway stations, and the facilities which do not require line earthing or protective functions such as electricity supplied for signalling the train. Also, will describe a countermeasure for the accident from a grounding fault.

  • PDF

A Study for Decrease Accident from Falls at the Construction Sites - Focused on Under 2nd Floor (건설현장의 추락재해 감소방안을 위한 연구 - 2개층 이하 높이 추락재해 감소 방안)

  • Park, Jun-Ky;Shin, Seung-Ha;Lee, Jung-Won;Kim, Kyung-Hwan
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.918-921
    • /
    • 2008
  • There are various accident at the Construction site like fall, electric shock, roll over, clash, fire, body cutting. By the way, falls are the most causes accidents. So, the best way of decreasing Construction accidents is decreasing falls. Already, there are many studies about falls accidents, but those studies were pointed out unrealistic because falls accidents are increasing. For that reason, this study look for more concrete device. In this study, grasp the cause of falls accident from 2007 to 2008. 06. 30. And then, stand on this factor I set my face to look for the causes of falls accident. This access means will drive to remove core causes, and then that means will decrease the falls accidents. Moreover that means will contribute decreasing the hole construction accidents.

  • PDF

The length of hospital stay of the industrial workers with back injury (산업재해 요통근로자의 재원기간에 관한 연구)

  • Lee, Bok-im
    • Korean Journal of Occupational Health Nursing
    • /
    • v.9 no.1
    • /
    • pp.18-29
    • /
    • 2000
  • Back injury is frequent in industry workers and is a common cause of productivity loss. It has been reported that the insured of industrial accident insurance tend to stay in hospital longer than that of other types of insurance. The purpose of this study was to identify factors affecting the length of hospital stay for the treatment of back injury in the workers under industrial accident insurance. The results of this study help insurers develop reasonable industrial accident insurance policy for back injury claims and prevention strategies of work-related back injury. A total of 2,949 patients whose industrial accident insurance claim has been approved for the treatment of work-related back injury from January to December 1999 were included in this study. Relationship between the length of hospital stay and characteristics of patient, work place, back injury, and hospital were assessed using ANOVA, t-test, simple linear regression and multiple resgression. The major findings of this study are as follows : 1. The average length of hospital stay(LOS) was 91.82 days, respectively. 2. Characteristics of Patient LOS of male patients was longer than that of female patients, there was positive correlation between age and LOS and between average wage and LOS. Working period was negatively correlated with LOS. Distance from resident to hospital was positively correlated with LOS and LOS was significantly different dependign on type of duty. 3. Characteristics of Work Place LOS was significantly different depending on types of industry and geographical region of work place. Size of work place was positively correlated with LOS. 4. Characteristics of Back Injury Occupational back pain required shorter LOS compared with back injury due to electric shock. Number of concomitant illnesses and severity of disability were positively correlated with LOS. 5. Characteristics of Hospital Patients treated in community hospitals required significantly longer LOS. Treatment in hospitals with rehabilitation program required decreased LOS. This was more prominent as number of physicians specialized in rehabilitation. 6. Multiple regression analysis revealed that distance form resident to hospital, geographical region of work place, size of work place, number of concomitant illnesses, severity of disability, and type of hospital were factors affecting LOS.

  • PDF

High Voltage Wiring System Evaluation Methode of FCEV (Fuel Cell Electric Vehicle) (수소연료전지 자동차용 고전압 배선 시스템 평가 기술 개발)

  • Lim, Ji-Seon;Lee, Jeong-Hun;Lee, Hyo-Jeong;Na, Joo-Ran
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.4
    • /
    • pp.330-336
    • /
    • 2012
  • FCEV uses 250 ~ 450 V instead of using 12 V battery. High voltage vehicle can cause electric shock, fire and explosion accident. Therefore, it has potential factors that can cause hazard of safety for users. United states of America and Europe legislate regulations such as ECE R100, FMVSS 305 for regulating electrical safety during driving or after collision. The company manufacturing high voltage components must do advanced R&D about Method for improving and confirming the safety of high voltage. We develop the specific hardware components of high voltage wiring system for the power train system and power supply system of Hyundai Motors FCEV. This paper shows test method of insulative performance for securing the electrical safety of high voltage components such as power cable, connectors and buss-bar, and proposals the guide line value for human safety of FCEV according to the test result of our development components.

A Study on the Properties Analysis and Estimation of Odor Detection System (향 검지 시스템의 특성 해석 및 평가에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.1-5
    • /
    • 2009
  • We studies wish to investigated establishment form of cabinet board, and confirm possibility of electrical disaster prevention through reappearance experiment of odor detection system. Established breaker consists of MCCB, RCD order in cabinet board for house, but industry is used together with. When imposed shock using shaker to terminal block that contact becomes in appropriate, flame was made sure. According to result that experiment attaching odor capsule in terminal block, capsule commissioned exactly by occurred heat. According to establishment position of sensor, difference of inspection time was about 10 seconds. Estimate odor inspection system by thing which electrical device accident prevention is available. When there is abnormal generated heat in connection of electric wire, accident prevention estimates that is possible by giving an alarm state of overheat to administrator.

A Study on New Data Format of Electrical Shocks in the Environment of Smart Grids (스마트 그리드 환경에서의 전기 감전 재해 자료 형태에 관한 연구)

  • Kim, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.486-491
    • /
    • 2011
  • Since Korea has high accident rate for the electrical shock than other advanced countries, it causes very serious problems. In this paper, a new classification method for analyzing electricity accidents is proposed, which is based on the microscopic view while existing methods have been based at the macroscopic view point. Electrical accidents cases can be mainly divided by three cases, which are from live works, incompleteness of the grounding system and imperfectness of the safety education and public relations. New data format of electrical shocks are proposed in the environment of smart grids.

A study on the analysis of actual main line systems of entertainment places (공연장내 간선설비에 대한 현장실태분석 연구)

  • Bae, S.M.;Kim, H.S.;Gil, H.J.;Yi, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1765-1767
    • /
    • 2003
  • The standard of living has been getting higher by reason of industrialization and economic growth. It makes people have more cultural desire(wants). Because of reasons mentioned above, a number of entertainment place and performance with high-tech is increased. This has been brought also increasing a number of electrical accident such as electrical shock, electrical fires and accidents of electrical facilities. This paper suggests technical, operational and special precautions of actual electric main line systems in entertainment places and is also written on the purpose of being applied with related provisions to designing electrical facilities, construction, check-up and inspection and maintenance for preventing further electrical disasters in entertainment places.

  • PDF

Simulation of a High Voltage Electric Shock Accident using a Human body Model (인체모델 이용한 고전압 감전사고 모의)

  • Jang, Tae-Jun;Jung, Yeon-Ha;Song, Kil-Mok;Roh, Young-Su;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2238-2240
    • /
    • 2005
  • 고전압 감전은 순간적인 사고로서 접촉사고와 비접촉 사고로 나뉘어 진다. 이러한 사고를 모의하기 위하여 고전압 임펄스 발생장치를 이용하여 접촉과 비접촉시의 사고를 모의하고자 한다. 본 논문에서는 우리나라의 배전선로인 3상 4선의 수전설비의 감전위험성을 조사 한 후 인체모델을 가지고 직접 및 간접적으로 가해지는 전압, 전류를 실험을 통해 측정하고자 한다.

  • PDF