하남IC 상수도관로 대지비저항 측정 및 분석에 따른 전기방식 시공방안 제시 (A Proposal for Construction Plan of Electric Corrosion from Measurement and Analysis for Earth Resistivity of Ha-Nam IC Water Pipe Line)

  • 신강욱;이은춘;홍성택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.355-357
    • /
    • 2000
  • Measurement used electricsal sounding(MacOHM 2115, Japan) for grounding resistance of Jung-Bu highway Ha-Nam IC about 500m. To applied measurement method is fall of potential method and analysis earth resistivity used ESII(Electrical Sounding Interactive Interpretation) program. This result propose for construction plan of electric corrosion.

  • PDF

원격탐사, 전기탐사, 전자기탐사 및 시추공영상의 융합적 분석을 통한 서산지역 방조제 누수구역 판별 (Investigation of Water Leakage in Seosan A-Region Sea Wall using Integrated Analysis of Remote Sensing, Electrical Resistivity Survey, Electromagnetic Survey, and Borehole Survey)

  • 홍성인;이동익;백광현;유영철;임국묵;유재형
    • 자원환경지질
    • /
    • 제46권2호
    • /
    • pp.105-121
    • /
    • 2013
  • 본 연구에서는 원격탐사, 전기비저항탐사, 전기전도도탐사(전자기탐사), 시추공 영상촬영법을 융합하여 효과적인 제방의 안정성 및 누수 평가 방법을 서산 A지구 방조제에 적용하여 제시하였다. Landsat ETM+열적외선 밴드를 사용하여 방조제 부근에서 다른 온도의 해수와 담수가 혼합되는 양상을 통해 누수의 존재, 규모 및 기간을 유추하였다. 전기비저항탐사를 방조제를 따라 실시하여 평균비저항 값 83.197 ${\Omega}$-m이하를 보이는 이상대의 수평적 수직적 분포를 확인하였다. 간조와 만조 시의 전기전도도 값의 분석을 통해 배경치의 영향을 최소화한 수평적 이상대 분포를 확인하였다. 시추공영상촬영을 통해 파쇄대의 수직적 분포양상과 기존 탐사법의 정확도를 확인하였다. 그 결과 전체 제방의 연장 중 41.7%에서 세 수평적 이상대 탐사법의 중첩구간이 확인되었으며, 시추공에서 확인된 수직적 파쇄양상을 고려할 때 누수구간이 제방단면의 중심부를 따라 상당부분 수평적으로 연장이 되어 방대한 양의 누수가 존재할 가능성이 높을 것으로 사료된다. 네 탐사법의 융합적 접근은 각 탐사방법이 가지고 있는 장점을 부각하고 단점을 보완하여 수평적 및 수직적인 누수구간과 기간의 확인 및 판별이 가능하고, 시추공에서 확인된 수직적 파쇄양상의 수평적 연장성을 예측하는데 높은 신뢰도를 보인다 할 수 있다.

접지된 2개의 유전층위에 저항띠 양끝에서 0으로 변하는 저항띠 격자구조에서의 전자파산란 해석 (Analysis of Electromagnetic Scattering by Resistive Strip Grating with Zero Resistivity at the Strip-Edges On a Grounded 2 Dielectric Layers)

  • 윤의중
    • 한국항행학회논문지
    • /
    • 제10권2호
    • /
    • pp.152-158
    • /
    • 2006
  • 본 논문에서는 접지된 2개의 유전체평면 위에 저항띠 양끝에서 0으로 변하는 저항율을 갖는 저항띠 격자구조의 전자파 산란문제를 수치해석 방법인 FGMM(Fourier-Galerkin Moment Method)을 이용하여 스트립 폭 및 주기, 유전체층의 비유전율 및 두께, 입사각에 따라 수치해석하였다. 산란전자계는 Floquet 모드함수의 급수로 전개하였다. 경계조건은 미지의 계수를 구하기 위하여 적용하였고, 저항띠 경계조건은 접선성분의 전계와 스트립의 유도전류와의 관계를 위해 이용하였다. 저항띠의 변하는 저항율은 저항띠의 양끝에서 0으로 변하는 경우를 취급하였고, 이때 유도되는 표면 전류밀도는 2종 Chebyshev 다항식의 급수로 전개하였다. 본 논문에서 변하는 저항율이 0을 갖는 정규화된 반사전력은 기존 논문의 결과와 매우 잘 일치하였다.

  • PDF

500 kV 송전철탑 접지설계를 위한 대지저항률 산정에 관한 연구 (A Study on the Identification of Specific Earth Resistivity for Grounding Design of 500 KV Transmission Towers)

  • 최종기;이성두;이동일;정길조;김경철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.703-705
    • /
    • 2005
  • 접지설계에 있어서 토양의 전기적 특성은 접지극의 형상과 더불어 가장 중요한 설계요소 중 하나이며 이러한 토양의 전기적 특성은 접지극이 매설될 지역의 고유한 저항률, 즉 고유저항률(specific earth resistivity)로 대표되어 왔다. 이처럼 고유저항률에 근거한 수작업 접지설계는 복잡한 구조와 특성을 갖는 실제 토양을 균일한 매질로 등가화하는 절차를 필요로 한다. 본 논문에서는 미얀마 500 kV 송전철탑 수작업 접지설계를 위하여 수평다층토양을 균일매질로 등가화하는 절차를 제시하였다.

  • PDF

Resistivity Variation of Nickel Oxide by Substrate Heating in RF Sputter for Microbolometer

  • Lee, Yong Soo
    • 센서학회지
    • /
    • 제24권5호
    • /
    • pp.348-352
    • /
    • 2015
  • Thin nickel oxide films formed on uncooled and cooled $SiO_2/Si$ substrates using a radio frequency (RF) magnetron sputter powered by 200 W in a mixed atmosphere of argon and oxygen. Grazing-incidence X-ray diffraction and field emission scanning electron microscopy are used for the structural analysis of nickel oxide films. The electrical conductivity required for better bolometric performance is estimated by means of a four-point probe system. Columnar and (200) preferred orientations are discovered in both films regardless of substrate cooling. Electric resistivity, however, is greatly influenced by the substrate cooling. Oxygen partial pressure increase during the nickel oxide deposition leads to a rapid decrease in resistivity, and the resistivity is higher in the cooled nickel oxide samples. Even when small microstructure variations are applied, lower resistivity in favor of low noise performance is acquired in the uncooled samples.

접지된 유전체 평면위의 스트립 양끝에서 0 저항율을 갖는 저항띠 격자구조에 의한 H-분극 산란 (H-Polarized Scattering by a Resistive Strip Grating with Zero Resistivity at Strip-Edges Over a Grounded Dielectric Plane)

  • 윤의중
    • 한국항행학회논문지
    • /
    • 제15권3호
    • /
    • pp.349-354
    • /
    • 2011
  • 본 논문에서는 스트립 폭과 격자주기, 유전체 층의 비유전율과 두께, 그리고 transverse electric (TE) 평면파의 입사각에 따른 접지된 유전체 평면위의 스트립 양끝에서 0 저항율을 갖는 저항띠 격자구조에 의한 H-분극산란 문제를 Fourier-Galerkin Moment Method (FGMM)를 이용하여 해석하였다. 저항띠의 변하는 저항율은 저항띠의 양끝에서 0으로 변하는 경우를 취급하였고, 이때 저항띠 위에서 유도되는 전류밀도는 직교다항식의 일종인 2종 Chebyshev 다항식의 급수로 전개하였다. 반사전력의 급변점들은 공진효과에 기인한 것으로 과거에 wood's anomallies라고 불리워지며, 반사전력에 대한 수치결과들은 기존 논문의 균일 저항율의 수치 결과들과 비교하였다.

대지저항률에 따른 최적화 접지 해석 (The Optimization Grounding Analysis for Soil Resistivity)

  • 정연하;장태준;곽희로;노영수;송길목
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.241-245
    • /
    • 2004
  • The electric safety tends to be more important according to electric facilities's increase and its use in these days. This paper analyzes soil resistivity of two areas in the country using CDEGS(Current Distribution, Electromagnetic Interference, Grounding and Soil Structure, Canada). We designed rod and mesh grounding system and made a comparative study of ground resistance, GPR(Main Electrode Potential Rin), step voltage and touch voltage. Then we could analyz only the safety but also economical efficiency in elocution of grounding. As a result of simulation, ground resistance, GPR(Main Electrode Potential Rise), step voltage and touch voltage became higher in proportion to soil resistivity. Therefore we expect to estimate the propriety of grounding system design through accumulation and analysis of data in consideration of characteristics of soil.

  • PDF

전자기법을 이용한 3Cr-lMo-0.25V 강의 물성 평가 (Evaluation on Material Properties of 3Cr-lMo-0.25V Steel by Electromagnetic Methods)

  • 남영현;안봉영;이승석
    • 대한기계학회논문집A
    • /
    • 제27권2호
    • /
    • pp.255-261
    • /
    • 2003
  • It is advantageous to use NDE methods to assess the mechanical properties of materials since the conventional method is time-consuming and sometimes requires cutting of sample from the component. The NDE parameters such as ultrasonic velocity and attenuation, electric resistivity, and magnetic coercive force and remanance have been utilized to evaluate changes of material properties due to heat treatment condition. It has been found that changes of materials properties under quenched and tempered/PWHT treatments could not be detected using EMAT and Electrical resistivity methods. However, victors hardness and magnetic hysteresis loop decreased with heat treatment procedures. These results were obtained using 3Cr-lMo-0.25V steel. The magnetic parameters were found to be most sensitive to changes of material properties.

시료 파괴 시 발생하는 SP에 관한 기초 연구 (The basic study about streaming potential generated by specimen fracture)

  • 김종욱;조성준;박삼규;성낙훈;송영수
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.291-296
    • /
    • 2007
  • We measured potential waveform of load, displacement, micro electric signal generated by rock and mortar fracture using PXI A/D Converter. The rock type used for measurement was used granite, limestone and sandstone, and mortar specimen. we made measuring equipment of physical properties to confirm basic information of physical properties, measured physical properties of rock engineering, electric resistivity and seismic velocity. Potential waveform system was built using PXI A/D Converter and measured potential waveform of load, displacement, micro-electric signal generated using this during uniaxial compressive test by the specimen finished such test of physical properties. Using the saturated rock and mortar specimen, micro electric signal increased, and It didn't increase a signal in dried rock and mortar specimen according as load and strain rate increases. But signal also increased in saturated or dried specimen in case of sandstone. It was possible to check the close correlation relationship the signal and fracture behavior by a compressive load as the signal of fracture position was increased bigger than the other position. It was also possible to check the correlation relationship between physical properties and micro geo-electric signal.

  • PDF

인체전류를 기반으로 하는 감전의 위험성 평가방법 (A Method for Evaluating Electric Shock Hazards Based on Human Body Current)

  • 이복희;유양우;최종혁
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.108-114
    • /
    • 2011
  • In order to mitigate the possible hazards from electric shock due to the touch and step voltages, the high resistivity material such as gravel is often spread on the earth's surface in substations. When the grounding electrode is installed in two-layer soil structures, the surface layer soil resistivity is different with the resistivity of the soil contacted with the grounding electrodes. The design of large-sized grounding systems is fundamentally based on assuring safety from dangerous voltages within a grounding grid area. The performance of the grounding system is evaluated by tolerable touch and step voltages. Since the floor surface conditions near equipment to be grounded are changed after a grounding system has been constructed, it may be difficult to determine the tolerable touch and step voltage criteria. In this paper, to propose an accurate and convenient method for evaluating the protective performance of grounding systems, the propriety of the method for evaluating the current flowing through the human body around on a counterpoise buried in two-layer soils is presented. As a result, it is reasonable that the grounding system performance would be evaluated by measuring and analyzing the current flowing through the human body based on dangerous voltages such as the touch or step voltages and the contact resistance between the ground surface and feet.