• 제목/요약/키워드: electric railway system

검색결과 773건 처리시간 0.027초

철도역사의 전기설비 안전성에 관련된 연구 (A Study on Safeties for Railway Station, Electric Equipment)

  • 조철호;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.287-292
    • /
    • 2005
  • Safety of Station electric equipment is not analysed yet. this paper try the safety first times on the basis of hazards which railway stations contain. The stations use many electric equipment such as lights, escalator and elevator for facilitating for passengers and public moving, HVAC system making good environment and so on. The electric equipments could be changed to harmful systems to passengers and publics resulting from abnormal operation condition. To ensure safeties in the station, we need to identify and analyse the hazards in the station and to provide risk mitigation methods. In this paper, we shows processes and methods to ensure the safety, how to identify and analyse the hazards. Finally, we demonstrate how to mitigate the potential risks in the stations.

  • PDF

고속전철 시스템의 정적평형 및 선형진동 해석 (Static equilibrium and linear vibration analysis of a high speed electric train system)

  • 김종인;유홍희;황요하
    • 한국철도학회논문집
    • /
    • 제2권4호
    • /
    • pp.1-8
    • /
    • 1999
  • A formulation to perform static equilibrium and linear vibration analysis is presented in this paper. The formulation employs minimum number of equations of motion which are derived by using a partial velocity matrix. The static equilibrium analysis is performed first, then the linear vibration analysis is performed at the static equilibrium position. By using the formulation presented in this paper, static equilibrium and linear vibration analysis of a high speed electric train system are performed. A single bogie system, a power car vehicle, and a train system which consists of five vehicles are analyzed, respectively. Natural frequencies and a few lowest mode shapes of the two are identified in this paper.

  • PDF

경부고속철도 회생 에너지 저장시스템 성능 분석 (Performance Analysis for Regenerative Energy Storage System in Kyoung-bu High Speed Railway)

  • 장민주;전용주;노영환
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1391-1397
    • /
    • 2015
  • Recently, various researches are conducted in the application of regenerative energy produced during the operation of an electric locomotive. Regenerative energy is produced by a generator in the brake procedure. The generator is operated by kinetic energy of an electric railroad using an electric motor. The process of producing regenerative energy varies with the current type of a railroad and its running condition. The quality of electric power can be improved and electric energy can be utilized effectively, especially in the use of an energy storage system (ESS). Thus, it is necessary to apply ESS into AC section and high speed railway. This study analyses the composition of the regenerative ESS equipment installed in Yong-Jeong sectioning post, operational principle, charge and discharge algorithm and energy efficiency. The analysis shows that CO2 emissions can be reduced about 0.5 ton per a day. In addition, ESS helps saving the energy and the compensation of the voltage drop caused by the operation of high speed train when it is installed at the end of the feeder section. The number of high speed train will be increased continuously related to the electrification rate. Therefore, applying the ESS to high speed railway is expected to solve the instability of the feeder voltage and the equipment capacity problem caused by the high speed trains.

Tree 구조를 이용한 전철급전시스템의 신뢰도 평가 (Reliability Assessment of Railway Power System by using Tree Architecture)

  • 차준민;구본희
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.9-15
    • /
    • 2010
  • As catenary supply electric power directly to the railway system, it is very important to prevent an accident of a catenary for appropriate train operation. This paper proposed the assessment the outage data for "British Catenary Safety Analysis Report" and Korean data to compare the reliability of the railway system. The analyzed data were applied to Event Tree and Fault Tree algorithm to calculate the reliability indices of railway system. Event tree is created and gate results of fault tree analysis are used as the source of event tree probabilities. Fault tree represents the interaction of failures and basic events within a system. Event Tree and Fault Tree analysis result is helpful to assess the reliability to interpreted. The reliability indices can be used to determine the equipment to be replaced for the entire system reliability improvement.

동력분산형 고속철도의 주행성능 해석기술 연구 (Dynamic behavior analysis of the high speed EMC(Electric Multiple Unit))

  • 윤지원;박태원;이문구;전갑진;박성문;김정범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1160-1165
    • /
    • 2008
  • The development of a new railway vehicle is under progress through the Next Generation High-Speed Rail Development Project in Korea. Its aim is to develope fundamental technology of the vehicle that can run over 400km/h. The new distributed traction bogie system, 'HEMU'(High-speed Electric Multiple Unit), will be used and is different from previously developed high speed railway vehicles. Previous vehicles adopted push-pull type system, which means one traction-car drives rest of the vehicle. Due to the difference, investigation on dynamic behavior and its safety evaluation are necessary, as a part of verification of the design specification. In this paper, current progresses of researches are presented. And the High-Speed Railway vehicle system is evaluated for a dynamic characteristic simulation. Proper models including air-suspension system, wheel-rail, bogie and car-body will be developed according to the vehicle simulation scenario. International safety standard will be applied for final verification of the system. This research can propose a better solution when test running shows a problem in the parts and elements. Finally, the vehicle that has excellent performance will be developed, promoting academic achievement and technical development.

  • PDF

고속열차 투입에 따른 AT급전계통의 부하용량증가에 관한 사례연구 (A case study on the increasing load capacity of AT Feeder system with speed-up train)

  • 나연일;한성호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.694-698
    • /
    • 2005
  • 전기철도에 있어서 열차의 운행속도향상은 지속적으로 추구해야할 당면한 과제이며, 이를 위해서는 철도시스템 전반에 걸친 검토가 이루어져야 한다. 열차의 고속화는 차량기술 뿐만 아니라, 선로 구축물, 신호시스템, 운영기술, 전차선로, 급전시스템 등이 상호 연계되어 종합적으로 경제성을 고려하여 추진되어야 한다. 특히, 전기철도 급전계통의 경우만 보더라도 고속열차가 기존운영선로에 투입될 경우 차량의 집전성능향상, 전압강하대책, 설비용량대책, 궤도노반, 분기기, 신호의 고속화, 전차선로 구조물 검토 등 여러 가지 기술검토가 반드시 수반되어야 한다. 본 논문에서는 이 가운데 AT급전계통에서의 신규의 고속화 열차 투입에 따른 급전계통의 기술검토에 대한 접근방안을 제시하고 실 계통을 대상으로 부하용량 변화의 정도를 예측함으로써, 향후 국내 노선의 전반에 걸쳐 적용 가능함을 입증할 수 있었다.

  • PDF

멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동전력필터 (A Hybrid Active Power Filter for Electric-Railway Systems using Multi-Level Inverters)

  • 김윤호;김수홍;노성찬;이강희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1334-1339
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. Transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 5th harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system.

  • PDF

멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동전력필터 (A Hybrid Active Power Filter for Electric-Railway Systems using Multi-Level Inverters)

  • 김윤호;김수홍;노성찬;이강희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1427-1432
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. Transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 5th harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system

  • PDF