• 제목/요약/키워드: electric power generator

검색결과 736건 처리시간 0.037초

Performance Evaluation of Regenerative Braking System Based on a HESS in Extended Range BEV

  • Kiddee, Kunagone;Khan-Ngern, Werachet
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1965-1977
    • /
    • 2018
  • This paper proposed a regenerative braking system (RBS) strategy for battery electric vehicles (BEVs) with a hybrid energy storage system (HESS) driven by a brushless DC (BLDC) motor. In the regenerative braking mode of BEV, the BLDC motor works as a generator. Consequently, the DC-link voltage is boosted and regenerative braking energy is transferred to a battery and/or ultracapacitor (UC) using a suitable switching pattern of the three-phase inverter. The energy stored in the HESS through reverse current flow can be exploited to improve acceleration and maintain the batteries from frequent deep discharging during high power mode. In addition, the artificial neural network (ANN)-based RBS control mechanism was utilized to optimize the switching scheme of the vehicular breaking force distribution. Furthermore, constant torque braking can be regulated using a PI controller. Different simulation and experiments were implemented and carried out to verify the performance of the proposed RBS strategy. The UC/battery RBS also contributed to improved vehicle acceleration and extended range BEVs.

Soft Plasma Flash X-ray Generator Utilizing a Vacuum Discharge Capillary

  • Sato, Eiichi;Hayasi, Yasuomi;Usuki, Tatsumi;Sato, Koetsu;Takayama, Kazuyoshi;Ido, Hideaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.400-403
    • /
    • 2002
  • The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments were primarily performed in order to generate line spectra such as x-ray lasers. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbo-molecular pump, and a radiation tube with a capillary. A high-voltage condenser of 200 nF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were -10.8 kV and 4.7 kA, respectively. The x-ray durations observed by a 1.6 ${\mu}$m aluminum filter were less than 30 ${\mu}$s, and we detected the aluminum characteristic x-ray intensity using a 6.8 ${\mu}$m aluminum filter. In the spectrum measurement, two sets of aluminum and titanium electrodes were employed, and we observed multi-line spectra. The line photon energies seldom varied according to changes in the condenser charging voltage and to changes in the electrode element. In the case where the titanium electrode was employed, the line number decreased with corresponding decreases in the capillary length. Compared with incoherent visible light, these rays from the capillary were diffracted and diffused greatly after passing through two slits.

  • PDF

활선 고전력 케이블의 절연저항을 측정하기 위한 시스템 설계 및 측정결과 (Development of System and Measured Results for Measuring Insulation Resistance of High-Power Cables in Operation)

  • 엄기홍;김보경
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.165-170
    • /
    • 2016
  • 우리 나라에서 발전소가 전기를 생산하고 고전압 전력을 공급하기 위하여 채택한 XLPE 케이블(또는 CV케이블)은 포설된지 40년에 이르고 있다. 설치환경 및 사용조건에 다르겠지만, 설치 후 운전 상태에 있는 CV 케이블은 6~8년의 기간이 경과하면 열화가 발생하기 시작하고, 상태가 나빠지는 경우, 절연 파괴현상으로 인한 휴전 및 화재 사고가 발생한다는 많은 사례 보고가 있다. 근래에 포설한 케이블이라 할지라도 시공 불량이나 기타의 열악한 주변 환경으로 인한 악조건 상태에 노출되는 경우, 6~8년 미만의 시점에서도 사고가 발생할 수가 있다. 사고를 미연에 방지하기 위하여 케이블의 동작상 태를 정기적으로 감시 확인하여야 한다. 우리는 케이블의 사고를 체계적으로 감시 및 예방하기 위하여 측정 장비를 개발하였다. 이 논문에서 케이블의 절연 상태의 열화 상태를 감시하기 위하여 한국서부발전 주식회사(Korean Western Power Co. Ltd.)에 설치하여 운영 중에 있는 장비의 설계와 그 장비를 사용하여 측정한 결과즉, 케이블의 열화 과정을 나타내는 결과를 제시한다.

기력발전소 터빈조속기 제어로직 개선에 의한 발전기 부하추종성 향상 (계통주파수저하방지) (Load Following Operation Improvement by Governor Control Logic Modification of Thermal Power Plant (System Frequency Drop Prevention))

  • 이종하;김태웅
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.302-306
    • /
    • 2006
  • 기력발전소의 부하추종성능의 향상은 계통의 전력품질에 지대한 영향을 미치기 때문에 이를 위해서는 먼저 보일러, 터빈, 조속기 시스템과 제어알고리즘에 대한 분석이 필히 선행되어야 한다. 기력발전설비는 다양한 제어가구들 에 의해 운영되고 있고 조속기가 고장 난 경우에는 문제를 해결하는데 많은 시간이 필요하여 발전설비를 정지하지 않고서는 메커니즘 정비가 불가능하다. 계획되지 않은 발전시스템의 정지는 전력발전의 감소로 인해 경제적인 문제뿐만 아니라 전력공급의 차질에 지대한 지장을 주기 때문에 충분히 고려할 사항이다. 본 논문에서는 표준석탄화력 500MW 발전설비 ( 삼천포화력발전소 )에 있어서 계통주파수가 과다하게 장시간 저하될 경우에 기력발전기 제어특성이 나빠져 발전기의 출력이 저하되는 데 이에 대한 현상을 추이분석과 함께 제어로직의 분석 및 개선을 통해 계통 주파수가 저하되는 것을 방지하였고 이에 대한 사례를 소개한다.

광섬유 센서로 측정한 절연유에 따른 방전신호 특성 (The Characteristics of Discharging signal in various kinds of insulation oil using Optical Fiber Sensor)

  • 김태영;남진호;서광석;김상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1599-1601
    • /
    • 1999
  • The characteristics of ultrasonic signal in insulation oil were investigated by optical fiber sensor(OFS) utilizing Mach-Zehnder interferometer. For checking the response properties of OFS ultrasonic signal was generated by function generator in various kinds of insulation oil. The attenuation of ultrasonic signal linearly increased with the increase of viscosity of insulation oil in log scale. Discharging signal was produced by neele-sphere electrode system. Intensity of discharging signal was plotted in terms of cumulative $y^2$ and the intensity of discharging signal in new oil was little bigger than that in serviced one.

  • PDF

뇌임펄스전압파형의 개선에 관한 실험적 고찰 (A experimental study on the improvement of lightning impulse voltage waveforms)

  • 이정기;김민규;정주영;김익수;최익순;문인욱;강영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1854-1856
    • /
    • 2004
  • In this paper, there have been brief review about the important consideration in laboratory planning and designing 4.2MV impulse voltage generator(IVG), which enable to test and evaluate the UHV dielectric performance of power electric apparatus up to 765kV-class. To improve and reinforce the test ability of the IVG and itself against test object being tested by KERI hereafter, wide investigation and an analysis for a solution, especially overshoot compensation method. With the special consideration about those matters in settling down the 4.2MV IVG have been described with the experimental approaching.

  • PDF

Mixture of Cumulants Approximaton 법에 의한 발전 시물레이션에 관한 연구 (A Study on the Probabilistic Production Cost Simulation by the Mixture of Cumulants Approximation)

  • 송길영;김용하
    • 대한전기학회논문지
    • /
    • 제40권1호
    • /
    • pp.1-9
    • /
    • 1991
  • This paper describes a new method of calculating expected energy generation and loss of load probability (L.O.L.P) for electric power system operation and expansion planning. The method represents an equivalent load duration curve (E.L.D.C) as a mixture of cumulants approximation (M.O.N.A). By regarding a load distribution as many normal distributions-rather than one normal distribution-and representing each of them in terms of Gram-Charlier expansion, we could improve the accuracy of results. We developed an algorithm which automatically determines the number of distribution and demarcation points. In modeling of a supply system, we made subsets of generators according to the number of generator outage: since the calculation of each subset's moment needs to be processed rapidly, we further developed specific recursive formulae. The method is applied to the test systems and the results are compared with those of cumulant, M.O.N.A. and Booth-Baleriaux method. It is verified that the M.O.C.A. method is faster and more accure than any other method.

  • PDF

여러종류의 Organoclay에 대한 에폭시-나노콤포지트의 열적, 유전특성에 관한 연구 (Thermal, Dielectric Properties Characteristics of Epoxy-nanocomposites for Organoclay of Several Types)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제21권6호
    • /
    • pp.538-543
    • /
    • 2008
  • Nanostructured materials are attracting increased interest and application. Exciting perspectives may be offered by electrical insulation. Epoxy/Organoclay nanocomposites may find new and upgraded applications in the electrical industry, replacing conventional insulation to provide improved performances in electric power apparatus, e.g, high voltage motor/generator stator winding insulation, dry mold transformer, etc. In the paper work, the electrical and thermal properties of epoxy/organoclay nanocomposites materials were studied. The electrical insulation characteristics were analyzed through the permittivity characteristics. by analyzing the permittivity spectra, it was found that dielectric constant becomes smaller with increase frequency and becomes larger with increase temperature. This indicates restriction of molecular motion and strong bonds at the epoxy/organoclay nanocomposites. The morphology of nanocomposites obtained was examined using TEM and X-ray diffraction. It has been shown that the presence of polar groups leads to an increased gallery distance and partial exfoliation. Nevertheless, full exfoliation of clay platelets has not been achieved.

태양광에너지전원의 주간설비이용율 추정에 관한 연구 (A Study on the Weekly Capacity Factor Assessment of Solar Cell Generator)

  • 박정제;오량;최재석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.468_469
    • /
    • 2009
  • The application of renewable energy in electric power systems is growing rapidly in order to make provision for the inequality of the climate, the dwindling supplies of coal, oil and natural gas and a further rise in oil prices. Solar cell generators(SCG) is one of the fastest growing renewable energy. A study on the renewable energy is getting more important for the application of renewable energy. This paper presents the capacity factor of SCG by calculating the probabilistic production energy of SCG.

  • PDF

IEC61850 기반의 Gateway 개발을 위한 이슈에 관한 연구 (A study on the key Issues for implementing the IEC61850 based Gateway)

  • 오무남;이석배;우천희;김정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.91_92
    • /
    • 2009
  • As the increasing integrity of VLSI, the BIST(Built-In Self Test) is used as an effective method to test chips. Generally the pseudo-random test pattern generation is used for BIST. But it requires too many test patterns when there exist random resistant faults. Therefore we propose a mixed test scheme which applies to the circuit under test, a deterministic test sequence followed by a pseudo-random one. This scheme allows the maximum fault coverage detection to be achieved, furthermore the silicon area overhead of the mixed hardware generator can be reduced.

  • PDF