• 제목/요약/키워드: electric potential

검색결과 1,345건 처리시간 0.03초

정지형 여자제어 시스템 개발 (Development of Analog Controlled Transformer-fed Static Excitation System)

  • 임익헌;류호선;정창기;류흥우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2184-2186
    • /
    • 1997
  • Potential-source controlled rectifier excitation system has been developed by KEPRI for synchronous generator in YOUNG-DONG thermal power plant. This paper describes the characteristics of redundant control system and transfer function of dual channel excitation control system. This system has been using a analog and digital circuit devices(hybrid type)

  • PDF

고속철도 시스템의 레일 전위 상승 해석 (Analysis on Voltage Rise of Rail in High speed Railway System)

  • 이종우
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권8호
    • /
    • pp.481-485
    • /
    • 2003
  • In electric railway system, potential of rail has been risen, for return-current flows through rail. The magnitude of rising voltage is different to railway feed system, ground admittance of rail and the load current. If rising voltage of rail is large, electric shock can be occurred to passengers and maintenance- worker, In this paper, we estimate the rising voltage of rail in high speed railway system and check the safety to human beings.

한의 진단을 위한 체표에너지 측정 시스템의 개발 및 평가 (Development and Evaluation of Body Surface Electric Energy Measurement System for Oriental Medical Diagnosis)

  • 김수병;권선민;강희정;임윤경;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제26권1호
    • /
    • pp.51-60
    • /
    • 2009
  • Objectives : It is considered not easy to diagnose the condition of acupoints or meridians. Oriental Medical instruments have rarely complied with Oriental Medical diagnostic/therapeutic theories. The aim of this study was to develop a system which measures meridian electric potential(MEP) in proportion to bio-electric charge for the purpose of Oriental Medical diagnosis. Method : To evaluate a meridian energy measurement system(MEMS), we carried out a performance test. For significance test, we conducted a clinical trial which measured the MEP of ST36(Chok-samni) on Stomach Meridian(ST). Results & Conclusions : We could evaluate the balance or the imbalance of the MEPs on the left/right ST36. Also, through the comparison of MEPs before and after meals, we could identify the correlation between the MEP and the condition of internal organs. Namely, MEP reflects the condition of acupoints/meridians and internal organs, therefore, we propose this new method for measuring and analyzing the condition of meridians and acupoints for Oriental Medical diagnosis.

  • PDF

Forecasting Market Shares of Environment-Friendly Vehicles under Different Market Scenarios

  • Bae, Jeong Hwan;Jung, Heayoung
    • 자원ㆍ환경경제연구
    • /
    • 제22권1호
    • /
    • pp.3-29
    • /
    • 2013
  • The purpose of this study is to estimate consumer preferences on hybrid cars and electric cars by employing a choice experiment reflecting the various market conditions, such as different projected market shares of green vehicles and $CO_2$ emission regulations. Depending on different market scenarios, we examine as to which attribute and individual characteristic affect the preferences of potential consumers on green vehicles and further, forecast the potential market shares of green cars. The primary results, estimated by a conditional logit and panel probit models, indicate that sales price, fuel cost, maximum speed, emission of air pollutants, fuel economy, and distance between fuel stations can significantly affect consumer's choice of environment-friendly cars. The second finding is that the unique features of electric cars might better appeal to consumers as the market conditions for electric cars are improved. Third, education, age, and gender can significantly affect individual preferences. Finally, as the market conditions become more favorable toward green cars, the forecasted market shares of hybrid and electric vehicles will increase up to 67% and 14%.

Introducing the Latest 3GPP Specifications and their Potential for Future AMI Applications

  • Koumadi, Koudjo M.;Park, Byong-seok;Myoung, Nogil
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.245-251
    • /
    • 2016
  • Despite the exponential throughput improvement in mobile communications systems, their ability to satisfy requirements of state-of-the-art and future applications of advanced metering infrastructure (AMI) is still under investigation. Challenges are mainly due to the inadequacy of third generation partnership project (3GPP) networks to support large amounts of devices simultaneously, while the number of AMI end-devices and the frequency of their data transmission increase with new AMI-based applications. In this introductory survey, innovative and future AMI applications and their communication requirements are first reviewed. Then, we identify challenges of 3GPP long term evolution (LTE) in enabling future AMI applications. More importantly, the latest improvements to LTE-A standard release 12 and 13 are reviewed and analyzed with regards to their potential to improve the quality of LTE-enabled AMI. It is found that 3GPP enhancements on machine type communications (MTC) standards will significantly enhance AMI communications. Beyond MTC specifications, non-MTC-specific enhancements such as carrier aggregation and multi-connectivity for user equipment will also contribute greatly to improving reliability and availability of AMI devices. The paper's focus is towards improved backhaul support for innovative and future AMI applications, beyond traditional automatic meter reading.

메타표면 반사계수 계산을 위한 정사각형 패치의 전기 분극률 계산 (Calculation of Electric Polarizability of Square Patch for Calculating Reflection Coefficient of Metasurface)

  • 이선규;이정해
    • 한국전자파학회논문지
    • /
    • 제29권8호
    • /
    • pp.594-598
    • /
    • 2018
  • 메타표면에 가장 많이 이용되는 전기적으로 작은 크기를 갖는 정사각형 패치에 전위 연속성을 이용하여 접선방향 전기 분극률을 계산 방법을 제안하였다. 패치의 경우, 중심에 위치한 등가 전기 쌍극자에 의한 패치 표면에서의 전위가 균일하지 않기 때문에, 분극률이 한 개의 값으로 정의되지 않는 문제가 있었다. 이를 해결하기 위하여 패치 표면을 메쉬로 나누고, 각 점에서 얻어진 분극률을 평균함으로써 등가 분극률을 계산하였다. 제안된 방법, 기존의 멱급수 3차항 근사식, 실험식의 결과를 비교하여 잘 일치함을 보였다. 제안된 방법으로 구해진 분극률을 generalized sheet transition conditions(GSTCs)에 적용하여 계산된 메타표면의 반사계수의 크기와 위상이 ANSYS HFSS(high-frequency structure simulator) 모의실험 결과와 잘 일치함을 보였다.

웨어러블 심전도 측정과 임상 심전도 측정과의 상관관계에 대한 연구 (A Study on the Correlationship between Wearable ECG and Clinical ECG Measurements)

  • 이강휘;이성수;김상민;이혁재;민경진;강현규;이주현;곽휘권;고윤수;이정환
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1690-1698
    • /
    • 2018
  • Recent advances in ICT technology have transformed many of our daily lives and attracted a lot of attention to personal health. Heart beat measurement that reflects cardiac activities has been used in various fields such as exercise evaluation and psychological state evaluation for a long time, but its utilization method is limited due to its differentiation from clinical electrocardiogram. Therefore, in this study, we could observe the change of the measured signal according to the change of the distance and the position of the measuring electrodes which are non-standard electrode configuration. Based on the electric dipole model of the heart, correlation with clinical electrocardiogram could be confirmed by synthesizing multiple surface potentials measured with a shorter electrode distance than standard one. From the electromagnetic point of view, the distance between the measuring electrodes corresponds to the distance that the electric potential by the cardiac electric dipole moves, and the electric potential measured at the body surface is proportional to the moving distance of the electric potential. Therefore, it is preferable to make the distance between electrodes as long as possible, and to position the measuring electrode close to the ventricle rather than the atrium. In addition, it was found that standard electrocardiographic waveforms could be synthesized by using arithmetic sum of multiple measuring electrodes due to the relationship of electrical dipole vectors, which is obtained by dividing and positioning a plurality of measuring electrodes on a reference electrode line, such as Lead-I, Lead-II direction. Also, we obtained a significant Pearson correlation coefficient ($r=0.9113{\pm}0.0169$) as a result of synthetic experiments on four subjects.

P300과 MMN(mismatch negativity)의 지형학적 상관연구 (A Topographically Correlational Study of P300 and MMN (mismatch negativity) in Healthy Subjects)

  • 김대식;김영배
    • 대한임상검사과학회지
    • /
    • 제39권3호
    • /
    • pp.256-263
    • /
    • 2007
  • P300 is widely used as a neurophysiological indicator of cognitive processing, which is known as reflecting controlled processing. MMN (mismatch negativity), early response prior to P300, is known as reflecting an early stage of information processing and having involuntary attention and automatic awakening or sensory memory. This study for normal people shows that electric potential of P300 and MMN are in close correlation (r=-0.673, p<0.05). That is, it is observed that the higher negative value electric potential of MMN measured at cerebral forehead-center has, the higher value electric potential of P300 measured at cerebral center-vertex has. This fact implies that working memory for temporary storage and operation of stimuli, and involuntary attention which constitute automatic information processing, an early stage of information processing, play a crucial role in efficient information processing. On the other hand, considering that MMN of cerebral forehead-center and P300 of cerebral center-vertex are in close correlation, it is necessary to pursue further study of cerebral parts which generate P300 and MMN in information processing.

  • PDF

영가철 충진 컬럼을 이용한 연속적인 물리화학적 수중 인 제거 (Continuous removal of phosphorus in water by physicochemical method using zero valent iron packed column)

  • 정주영;안병민;김정주;박주양
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.439-444
    • /
    • 2013
  • Excessive phosphorus in aquatic systems causes algal bloom resulting in eutrophication, DO depletion, decline in recreational value of water and foul tastes. To treat wastewater containing phosphorus including effluent of wastewater treatment plant, the continuous experiments were performed by using electrochemical way. The spherical ZVI and silica sand which act as physical filter are packed at appropriate volume ratio of 1:2. Electric potential is applied externally which can be changed as per the operational requirement. The results indicate that optimum hydraulic retention time of 36 minutes (10 mL/min at 1 L reactor) was required to meet the effluent standards. Lower concentrations of phosphorus (<10 mg/L as phosphate) were removed by precipitation by contact with iron. Thus, additional electric potential was not required. In order to remove high concentration phosphorus around 150 mg/L as phosphate, external electric potential of 600 V was applied to the reactor.

Electric Field-induced Charge Transfer of (Bu4N)2[Ru(dcbpyH)2-(NCS)2] on Gold, Silver, and Copper Electrode Surfaces Investigated by Means of Surface-enhanced Raman Scattering

  • Joo, Sang-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권8호
    • /
    • pp.1405-1409
    • /
    • 2007
  • The potential-induced charge transfer of the dye (Bu4N)2[Ru(dcbpyH)2-(NCS)2] (N719) on Au, Ag, and Cu electrode surfaces has been examined by surface-enhanced Raman scattering (SERS) in the applied voltage range between 0.0 and ?0.8 V. N719 is assumed to have a relatively perpendicular geometry with its bipyridine ring on the metal surfaces. A strong appearance of the carboxylate band at ~1370 cm-1 indicates that the carboxyl group will likely be deprotonated on the metal surfaces. As the electric potential is shifted from ?0.8 to 0.0 V, the ν (NCS) band at ~2100 cm-1 on the electrode surfaces appears to undergo a shift in frequency and intensity change. This indicated that the charge transfer between the dye and metal electrode surfaces had occurred. Electric-field-dependent charge transfer differs somewhat depending on the type of metal surfaces as suggested from the dissimilar frequency positions of the ν (NCS) band.