• Title/Summary/Keyword: electric potential

Search Result 1,345, Processing Time 0.034 seconds

A Study on the Generation of the Earth Potential and Communication Line Noise. (대지전위와 통신회선 잡음 발생에 대한 고찰)

  • Yeo, Sang-Kun;Park, Chan-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.33-38
    • /
    • 2007
  • This paper presents a experimental evidence of the generation of the earth potential and communication line noise from the electric railway. There is a critical measurement err in case of measuring the electrical power induced noise voltage and degree of cable balance in the field of earth potential generated. As a results, it has been found that the conventional cable has more noise immunity than shielded cable near the railway where the earth current flows through the sheath layer.

  • PDF

A Study on Verification of Acupuncture Therapy Effect by Bio-potential Analysis (생체전위 분석에 의한 침구치료 효과 규명에 관한 연구)

  • 이용흠;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.670-678
    • /
    • 2004
  • In oriental medicine, meridian is pathway of bio-energy, and basic an object of diagnosis/therapy. But, in western medicine, meridian has been accepted as action pathway of nerve-endocrine-immune system. Acupuncture effect has been regarded as not effect by transmission of bio-energy but action or response by stimulation. In this paper, when an acupuncturist's bio-energy is passed on(non-insulation) and when is not(insulation), we analysed electric potential on meridian/non-meridian to verify effect of acupuncture therapy. In the results, when bio-energy isn't passed on, bio-potential is reacted to only the first of 4 times acupuncture operating. But when bio-energy is passed on, it is reacted to 4 times, and potential on meridian is higher than that of on non-meridian. Electric potential for same acupuncture operating is different on non/meridians, which implies that physiological construction and bio-energy transmission material is different respectively. When is extracting acupuncture method, potential is higher than that of injection one. It implies that extracting method is more effect than injecting one, in aspect of acupuncture therapy effect. Therefore, acupuncture therapy effect is verified as effect of response by acupuncturist's bio-energy transmission rather than that by only acupuncture stimulus.

Study on the effect of DC voltage in oil-immersed transformer insulation system (DC 전압이 유입변압기 절연시스템에 미치는 영향에 관한 연구)

  • Jang, Hyo-Jae;Kim, Yong-Han;Seok, Bok-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1552-1553
    • /
    • 2011
  • The HVDC transformer which is one of the main equipments for HVDC(High Voltage Direct Current) electric power transmission systems is exposed to not only AC voltage but also the inflowing DC voltage which comes from the DC-AC converter systems. Therefore, the HVDC transformer insulation system is required to withstand the electric field stress under AC, DC and DC polarity reversal conditions. However the electric field distributions under those conditions are different because the AC electric field and DC electric field are governed by permittivity and conductivity, respectively. In this study, the changes of electric potential and electric field of conventional AC transformer insulation system under DC polarity reversal test condition were analyzed by FEM(Finite Element Method). The DC electric field stress was concentrated in the solid insulators while the AC electric field stress was concentrated in the mineral oil. In addition, the electric stress under that condition which is affected by the surface charge accumulation at the interfaces between insulators was evaluated. The stress in some parts could be higher than that of AC and DC condition, during polarity reversal test. The result of this study would be helpful for the HVDC transformer insulation system design.

  • PDF

Plasma Potential of Atmospheric Plasma Double Jets (대기압 플라즈마 이중 제트의 플라즈마 전위)

  • Kang, Han-Lim;Kim, Jung-Hyun;Kim, Hyun-Chul;Han, Sang-Ho;Cho, Gunagsup
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.312-321
    • /
    • 2012
  • The electric potential of plasma column is measured with the high voltage probe in a pair of atmospheric plasma jets operated by AC-voltage. According to the polarity of voltage applied to the electrodes, the polarity of plasma column potential has the same polarity of applied voltage. The high potential of plasma column at the side of high voltage electrode is decreased linearly along the plasma column to the ground side. Therefore, the plasma column seams to be a kind of resistor whose resistivity is a few 10s $M{\Omega}/m$. In the experiment of double-jets system, the polarity of plasma potential is verified to be the same polarity to the applied voltage. When the different voltage polarities are applied to the electrodes of double plasma jets, the attractive force is acted between two plumes at the merged plasma and the plasma potential is measured to be low as a few 10s V. When the same polarity of voltage is applied to the electrode, the repulsive force is acted and the plasma potential is measured to be high as a several 100s V at the merged plumes. In the exposure of plasma plume on the bio-substrate with the double plasma jets, the electric shock and thermal damage might be proportional to the plasma power which is the multiplication of the plasma potential and the plasma current.

Study on EMI Elimination and PLN Application in ELF Band for Romote Sensing with Electric Potentiometer (전위계차 센서를 이용한 원격센싱을 위한 ELF 대역 EMI 제거 및 PLN 응용 연구)

  • Jang, Jin Soo;Kim, Young Chul
    • Smart Media Journal
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 2015
  • In this paper, we propose the methods not only to eliminate ELF(Extremely Low Frequency) EMI(Electro-Magnetic Interference) noice for extending recognition distance, but also to utilize the the PLN for detecting starting instance of a hand gesture using electric potential sensor. First, we measure strength of electric field generated in the smart devices such as TV and phone, and minimize EMI through efficient arrangement of the sensors. Meanwhile, we utilize the 60 Hz PLN to extract the starting point of hand gesture. Thereafter, we eliminate the PLN generated in the smart device and circuit of sensors. And then, we shield the sensors from an electric noise generated from devices. Finally, through analyzing the frequency components according to the gesture of target, we use the low pass filter and the Kalman filter for elimination of remaining electric noise. We analyze and evaluate the proposed ELF-band EMI eliminating method for non-contact remote sensing of the EPS(Electric Potential Sensor). Combined with a detecting technique of gesture starting point, the recognition distance for gestures has been proven to be extended to more than 3m, which is critical for real application.

Research on Grounding Resistance for the Grounding Plate Electrodes (각판상전극의 접지저항에 관한 연구)

  • Koh, Hee-Seog;Shin, Su-Han;Kim, Ju-Chan;Choi, Jong-Gyu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.111-114
    • /
    • 2004
  • There are many electricity, electronics, and communication equipment which need to Grounding in the building. When electric current flows into a certain Grounding system in the same building, the potential of other Grounding system rises. This potential interference repuire surface potential of electrods by electrode shape. In this paper basic formula is deduced on the basis of both electrodes surface potential of Grounding electrode as a source of the potential interference and Grounding electrode which receive the potential interference. The degree of potential interference as multiple Grounding electrode is verified the simulated results by means of the simple model in advance.

  • PDF

Interference Coefficient of X axis for Electrodes using Variation of Plural Earth Electrodes (복수접지극의 변화에 따른 전극의 X축 간섭계수)

  • Kim Sung Sam;Kim Ju Chan;Song Won Pyo;Koh Hee Seog
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.449-451
    • /
    • 2004
  • In the building, there are a lot of electricity, electrodes, and communication equipment. Many of those equipment needs to earthing. Naturally, the earth electrodes are constructed in the site of a building. In such a situation, when electric current flows into a certain earthing system the potential of other earthing systems rises. That is, the potential interference will take place between the earth electrodes. The conventional study has been considered by only the relation of the distance between the earth electrodes using the potential distribution formula of earth surface. However, it is necessary to inquire strictly, taking the surface potential of electrodes by electrode form into consideration. In this paper, basic formula is deduced on the basis of both electrodes surface potential of earth electrode as a source of the potential interference and earth electrode which receives the potential interference.

  • PDF

Computer simulation of electric field distribution in FALC process (FALC 공정에서의 전계 분포 전산모사)

  • 정찬엽;최덕균;정용재
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.2
    • /
    • pp.93-97
    • /
    • 2003
  • The crystallization behavior of amorphous silicon is affected by direction and intensity of electric field in FALC(Field-Aided Lateral Crystallization). Electric field was calculated in a simplified model using conductivity data of Mo, a-Si, $SiO_2$and boundary conditions for electric potential at the electrodes. The magnitude of electric field intensity in each corner of cathode was much larger than that in the center of patterns, and the electric field direction was 50~60 degree outside to cathode. And electric field intensity at a relatively small pattern was larger than that of a large pattern.

Numerical Analysis of Arc-Heated Flow through a solution of Electric Field (전기장 해석을 통한 아크/열 유동 해석)

  • Kim Chin-Su;Oh Se-Jong;Choi Jeong-Yeol
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.72-77
    • /
    • 2000
  • This paper presents the results of the application of a computational fluid dynamics algorithm for the simulation of plasma flows of arc-heated jet. The underlying physical model is based on the axisymmetric form of the conservation equations that are coupled with an arc model including Ohm heating, electromagnetic forces. The arc model given as a source term in fluid dynamic equations is determined by a solution of electric potential field governed by an elliptic partial differential equation. The governing equation of electric field is loosely coupled with fluid dynamic equations by an electric conductivity that is a function of state variables. However, the electric fields and flow fields cannot be solved In fully coupled manner, but should be solved iteratively due to the different characteristics of governing equations. With this solution approach, several applications of arc flow analysis will be presented including Arc Thruster and Circuit Breaker.

  • PDF

Performance Evaluation of Protection against Electric Shocks for TT and TN Systems (TT, TN접지계통의 감전보호 성능평가)

  • Lee, Bok-Hee;Choi, Young-Chul;Yoo, Jae-Duk;Shin, Hee-Kyung;Yang, Soon-Man;Kim, Tae-Gi;Lee, Zu-Cheul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.315-318
    • /
    • 2009
  • Electric shock is the accident caused by the current through a person or animal's body. That is characterized by the physiological effects. In this paper, we evaluate performance of protection against electric shocks for TT and TN grounding systems which are used by a low voltage consumer nowadays. The performance of protection against electric shocks for TT grounding system is very excellent in equipotential area of the third class grounding, but the performance is poor outside the equipotential area. The performance of protection against electric shocks for TN grounding system is excellent because the potential difference is less than 50V. Accordingly, the performance of protection for TN grounding system is good as compared with that for TT grounding System.

  • PDF