• Title/Summary/Keyword: electric impedance

Search Result 588, Processing Time 0.027 seconds

Control Algorithm Development for an Arc Current Interruption (아크 전류 차단을 위한 제어알고리즘 개발)

  • 반기종;김낙교
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.3
    • /
    • pp.166-172
    • /
    • 2004
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this Paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the low voltage network. This arc Is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional control algorithm does not have the arc current interrupt function. Hence, Control algorithm of arc current is designed for the interruption of arc fault current which has the modified arc characteristics.

A Study on the Development of a Lightning Warning System by the Measurement of Electric Field at the Ground (용량성 프로브와 광전송회로를 이용한 광대역 전압측정장치)

  • Kil, Gyung-Suk;Song, Jae-Yong;Park, Dae-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.363-368
    • /
    • 2004
  • A reliable voltage measurement system is necessary to monitor status of power facilities in substations, which is easy to set up and is not influenced by electromagnetic interference in and around substation. In this paper, we described a voltage measurement system (VMS) which is composed of a capacitive voltage probe, an impedance converter, and an optical linker. To get a wide-band characteristic of the VMS, a high speed impedance converter was used, and the output impedance of the VMS was set at $50{\Omega}$ to match any types of observing instruments. The frequency bandwidth of the VMS. which was estimated by a step pulse, was ranges from 11.42 Hz to 13.65 MHz, and the VMS showed a good response characteristic in a high frequency domain such as impulse voltages as well as a commercial frequency voltage.

Performance verification on the Impedance Relay Method using Failure Simulator of AT Feeding System (AT 급전계통 고장 모의시험장치를 활용한 임피던스 계전방식의 성능검증)

  • Kim, Wan-il;Lee, Kye-Seung;Jung, No-Geon;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.2
    • /
    • pp.325-330
    • /
    • 2018
  • In this paper, we investigated the impedance method for searching fault detection point in case of an accident in the AC electric railway AT feeding system. For this purpose, simulation circuit modeling and prototype hardware are made based on the known numerical analysis. As a result of simulation modeling of the feeding system based on the numerical analysis of the impedance method confirmed that the modeling was properly implemented with an average error rate of 0.07%. Also, as a result of fault event by hardware simulator, it was confirmed that the breaker operation time is shortened and the fault current is decreased while the voltage is close to the supply voltage in the transient state as the point of the fault accident moves away from the substation(SS).

An Analysis of the Ground Potential Rises and Dangerous Voltages Associated with the Frequency of Ground Currents (접지전류의 주파수에 따른 대지표면전위 상승 및 위험전압의 분석)

  • Choi, Jong-Hyuk;Cho, Yong-Sung;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.97-103
    • /
    • 2011
  • The most important object of grounding systems is to protect human being from electric shock. Touch and step voltages are measured to evaluate the performances of grounding systems. Dangerous voltages have been largely studied by the power frequency fault currents, on the other hand, the ground current containing the high frequency components and surge currents haven't been considered. Many attempts about the grounding impedances reported in these days show that the performance of the grounding systems in high frequency range is very different with the ground resistance. It is necessary to analyze the dangerous voltages formed by the ground currents containing high frequency components. In this paper, the ground surface potential rises near the vertical and horizontal grounding electrodes are measured at the frequency of 100[Hz], 30[kHz], and 100[kHz]. Dangerous voltages are investigated with the frequency-dependent grounding impedance. As a result, the ground surface potential rise is increased as the grounding impedance increases. Touch and step voltages near the grounding electrode whose impedance increases with the frequency are sharply raised.

Three-Stage Power Management System Employing Impedance Coupler Switch for Triboelectric Nanogenerator (마찰전기 나노발전기를 위한 임피던스 커플러 스위치를 탑재한 3단계 전력 관리 시스템)

  • Yoon, Bo-Kyung;Lee, Jun-Young;Jun, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.243-250
    • /
    • 2020
  • Energy harvesting is a recent technology involving the harvest and utilization of extremely small surrounding energy. Energy harvesting research is conducted in various fields. Triboelectric nanogenerators (TENGs) are energy harvesting technologies that use static electricity generated by physical movement or friction. Although TENGs generate output power in microwatt levels, they experience high internal impedance compared with other energy harvesting generators, thereby making the continuous transfer of electric power to loads difficult. This study proposes a power management system for TENGs that consists of three stages, that is, an AC/DC rectifier, an impedance coupler switch with a capacitor bank, and a DC/DC converter. In addition, the selection method of the AC/DC rectifier and DC/DC converter is proposed to maximize the amount of power transferred from energy harvesting areas. Furthermore, the impedance coupler switch and capacitor bank are discussed in detail. The validity and performance of the proposed three-stage power management system for TENGs are verified using a prototype system.

The Characteristic Impedance and the Electric Field Uniformity of a GTEM Cell (GTEM cell의 특성 임피던스와 전계 균일도)

  • 이애경;양기곤
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.3
    • /
    • pp.523-532
    • /
    • 1994
  • A knowledge of the accurate characteristic impedance of a GTEM cell is very useful to design it. This paper discusses the characteristic impedance of a GTEM cell applicable to both susceptibility and emission measurements, considering opening angle of it. The over-RGM for analysis is described : this numerical method is operated with respect to the spherical coordinate system. Some results are compared with others and the validity of this analysis is estabished. The characteristic impedances of a GTEM cell with the variation of geometrical constructions on cross section are presented ; the effect of the opening angle on the characteristic impedance is show. Finally, the electirc field uniformities on a cross section of a GTEM cell are considered for various opening angles.

  • PDF

A New Simple Sensorless Control Method for Switched Reluctance Motor Drives

  • Xin Kai;Zhan Qionghua;Luo Jianwu
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.52-57
    • /
    • 2006
  • In this paper, a new 'impedance sensing' method is described. This method overcomes the shortcomings of the impedance sensing method. According to the new method, sensing voltage pulse is applied to the idle phase in the minimum inductance region and the beginning of the increasing inductance region to detect rotor position. The negative torque produced by the sensing voltage pulse can be neglected in the minimum inductance region and the efficiency of SRM is improved. In the minimum inductance region the back electromotive force (EMF) can be neglected. And in the increasing inductance region the EMF opposes the rise of current in the phase, so the position estimation scheme is reliable. Therefore the new 'impedance sensing' method is sufficiently precise even under the high back EMF effect. The adjustment of turn-on angle and turn-off angle is also easy to be realized. The technique is very useful in applications where cost or size is primary concerns, such as electric bicycle drives. Experimental results are presented to verify the proposed method.

A Low Impedance and Short Guided-Wavelength Microstripline Employing a Periodically Perforated Ground Metal and Its Application to Miniaturized Ratrace MMIC (주기적 홀을 가지는 접지 금속막을 이용한 저임피던스/단파장 선로와 MMIC용 소형 레트레이스에의 응용)

  • Yun, Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.7
    • /
    • pp.727-733
    • /
    • 2003
  • In order to realize miniaturized and low-impedance MMIC passive component, a novel microstripline structure employing periodically perforated ground metal was proposed. The novel microstripline structure showed much lower impedance, and shorter guided-wavelength than conventional one. Using the novel microstripline with periodically perforated ground metal, a miniaturized 15 $\Omega$ ratrace was fabricated. The line width of the ratrace was 20 $\mu\textrm{m}$, and the size of it was 0.375 mm$^2$, which is 9.3 % of conventional one. The ratrace exhibited good RF performances from 20 to 30 GHz.

Modified SDIE MLFMM Method for Inhomogeneous Impedance Material Containing PEC or PMC Region (PEC 또는 PMC 영역을 포함하는 불균일 임피던스 매질의 산란 해석을 위한 수정된 SDIE MLFMM 방법)

  • Lee, Hyunsoo;Koh, Il-Suek;Yoo, Ji Hee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.805-810
    • /
    • 2018
  • A coated perfect electric conductor(PEC) interface to reduce scattered fields can be efficiently modeled by using the impedance boundary condition. The self-dual integral equation(SDIE) proposed by Yan et al. may be an efficient multi-level fast multipole method (MLFMM) formulation for the impedance object. This equation can be applied to an inhomogeneous impedance material, but its accuracy can be degenerated when the material contains a PEC or perfect magnetic conductor(PMC) region. In this paper, we modify the original SDIE formulation for an inhomogeneous object containing a PEC or PMC region and numerically verify its accuracy.

Design of HTS power cable with fault current limiting function

  • Kim, Dongmin;Kim, Sungkyu;Cho, Jeonwook;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.1
    • /
    • pp.7-11
    • /
    • 2020
  • As demand for electricity in urban areas increases, it is necessary to improve electric power stability by interconnecting neighboring substations and high temperature superconductor (HTS) power cables are considered as a promising option due to its large power capacity. However, the interconnection of substations reduces grid impedance and expected fault current is over 45 kA, which exceeds the capacity of a circuit breaker in Korean grid. To reduce the fault current below 45 kA, a HTS power cable having a fault current limiting (FCL) function is considered by as a feasible solution for the interconnection of substations. In this study, a FCL HTS power cable of 600 MVA/154 kV, transmission level class, is considered to reduce the fault current from 63 kA to less than 45 kA by generating an impedance over 1 Ωwhen the fault current is induced. For the thermal design of FCL HTS power cable, a parametric study is conducted to meet a required temperature limit and impedance by modifying the cable core from usual HTS power cables which are designed to bypass the fault current through cable former. The analysis results give a minimum cable length and an area of stainless steel former to suppress the temperature of cable below a design limit.