Performance verification on the Impedance Relay Method using Failure Simulator of AT Feeding System |
Kim, Wan-il
(Dept. of Transportation System Engineering, Korea National University of Transportation)
Lee, Kye-Seung (Dept. of Railway Vehicle & Operation System Engineering, Korea National University of Transportation) Jung, No-Geon (Dept. of Railway Vehicle & Operation System Engineering, Korea National University of Transportation) Kim, Jae-Moon (Dept. of Transportation System Engineering, Graduate School of Transportation, Korea National University of Transportation) |
1 | W. I. Kim, K. S. Lee, C. Y. Chang, K. W. Koo, J. M. Kim, "A Study on the Impedance Fault Location Method Using AT Feeding System Simulator", Korean Institute of Electrical Engineers Conference, 2017. |
2 | Dong-Sik Son, "A study on Auto Transformer protective method for AC electric railway system", Master's degree paper, 2014. |
3 | Min-Joo Jang, "A Study on Improvement Methodology of Fault Location Scheme in AC Electric Railway", Doctor's degree paper, 2016. |
4 | H. Lee, N.G. Jung, W. I. Kim, Y. S. Kim, J. M. Kim, "Comparative Analysis on the Characteristic according to Fault Location Estimation Technique in AT Feeding System", Korean Institute of Electrical Engineers Conference, 2016. |
5 | No-Geon Jung, Ki-Sik Lee, "The New Approach of the Impedance Calculation Method of Fault Current Analysis in the AT Feeding Method of the Electric Railway", Journal of Electrical Engineering & Technology Vol. 11 No. 5, pp. 1519-1525, September, 2016. DOI |