• Title/Summary/Keyword: electric field measurement

Search Result 455, Processing Time 0.028 seconds

A Study of Electromagnetic Interference in Power Line Communication (전력선 통신에서의 전자파 장해에 관한 연구)

  • Lee Jin-Taek;Chun Dong-Wan;Park Young-Jin;Lee Won-Tae;Shin Chul-Chai
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.12
    • /
    • pp.620-625
    • /
    • 2004
  • In this paper, we studied the emissive electric field due to the communication signal and the noise in medium voltage power-line. There are many types of conductive noise in power-line channel, which gives rise to radiation. And if the DMT carrier signal was excited, the current by this term was added to the current by noise and, generate radiation. We calculated input impedance by means of signal input network model of medium voltage power-line channel for calculating these currents. We calculated currents by input impedance and, calculated the emissive electric field by this calculated currents. From the measurement results, we knew that the measured results are very similar to the calculated results and if the input signal power level was higher than -40 dBm, the emissive electric field exceeds FCC radiation limit level 69.5 dB$\mu$V/m.

The principle of a electrorheological polishing for a small part (ER유체를 이용한 미세연마의 원리)

  • 김욱배;이상조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.968-971
    • /
    • 2002
  • Two decisive mechanisms of the electrorhological polishing for a small part(for example, a aspherical surface in a micro lens) are explained. Firstly, non-uniform electric field generated in the polishing structure increases a shear stress of ER fluids which is maximized dramatically near the tool, therefore, substrate adjacent to the tool can be removed effectively by mixed abrasives in the ER fluid. Secondly, abrasives in a non-uniform electric field are governed by the dielectrophoretic phenomena. Abrasives move toward the tool because the field gradient is highest near the tool and then abrasives are actively holded in that area. This phenomena is observed and evaluated by the optical measurement.

  • PDF

Implementation of Optical Magnetic Field Sensor for Measurement of Over Current (과전류 계측을 위한 광자계센서의 구현)

  • Park, Hae-Soo;Roh, Jong-Dae;Kim, Yo-Hee;Park, Byung-Seok;Ahn, Seong-Joon;Jo, Hong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1871-1873
    • /
    • 1997
  • The conventional current transformers are often take faults and out of order that for detect to over current of electric power lines because electromagnetic interference. But, it is possible to implement protection relay of high reliability using optical magnetic field sensor which are immunity and small size. The optical magnetic field sensor is possible to rapidly detect to over current and recover when electric power line have fault. And it is not necessary to make with capacitance of electric power lines as optical magnetic field sensor is have linearity from 0 to about 20kA. In this study, we designed and constructed compensative feedback circuit in order to minimize of optical power intensity variation with environ- mental variations(temperature, drive current) of light source. And this system have highest optical advantages and reliability.

  • PDF

Characteristic of Magnetic Fields Distribution in 345/154KV outdoor Substation (345/154KV 전력소 구내의 자계 분포 특성)

  • Sa, J.W.;Kim, S.M.;Hong, J.P.;Jeon, H.T.;Hahn, S.C.;Joo, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.97-99
    • /
    • 1997
  • For two decades and more, a lot of research work on the biological effects of EMF (Electromagnetic Field) on human health have been reported. Electric facilities in a typical substation are the main source of magnetic field. This paper presents the measurement and analysis of magnetic field in 345/154KV outdoor substation. The magnetic field depends on the currents which distributed by electric facilities. The result of this paper will be able to be used as basic informations to reduce the level of EMF from the electric utility facilities.

  • PDF

The Usability of Zinc Electrode using Wireless Measuring System of Electric Potential (무선전위측정시스템에 사용하는 아연전극 활용성 검토)

  • Lee, Jong-Rark;Leem, Sa-Hawn;Kim, Sang-O
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.177-180
    • /
    • 2006
  • This study is to make a basic study if solid zinc (Zn) can be used for buried reference electrode, so we examined the adequacy of zinc as reference electrode by using zinc which showed regular electrode for buried period. The deference of electric potential if zinc electrode for corrosion factor such as soil resistivity or pH didn't show fixed trend and there was no clear trend on the change of measurement period. From field test, it is known that the natural electric potential difference of CSE electrode and zinc electrode is 1,100mV, but the electric potential of zinc electrode for CSE electrode in the natural soil and copying soil was 1,094~1,158mV. There was no fixed trend on the change of measurement period and electric potential difference of zinc electrode for corrosion factors such as soil resistivity or pH. Consequently, there was 40~60mV of electric potential difference in every copying soil during the experiment measurement.

  • PDF

A Study on the Development of a Lightning Warning System by the Measurement of Electric Field at the Ground (대지전장측정에 의한 뇌경보시스템 개발에 관한 연구)

  • Kil, Gyung-Suk;Lee, Sung-Keun;Song, Jae-Yong;Kim, Jum-Sik;Kwon, Jang-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.250-258
    • /
    • 2001
  • In this study, a lightning warning system (LWS) which can predict a lightning return stroke is developed, and the LWS is based on the measurement of electric field intensity at the ground level. The LWS consist of a rotation-type field mill as an electric field sensor, an impedance changer, a two-stage amplifier, and a microprocessor unit. From the calibration experiment, the frequency bandwidth and the maximum resolution of the LWS are $DC{\sim}200\;[Hz]$ and 73 [V/m], respectively. Also, the LWS can measure the electric field strength caused by a thunderstorm up to 18.7 [kV/m] at the ground. To ensure the sensing ability of the developed LWS in an actual situation, computer simulation using thundercloud models was carried out, and the result showed that the LWS can monitor the movement of thunderclouds within 6 [km] from the observation site.

  • PDF

Optical Current Measuring System for Compensating Interference by Adjacent Electric Wires

  • Cho, Jae-Kyong
    • Journal of Magnetics
    • /
    • v.12 no.4
    • /
    • pp.156-160
    • /
    • 2007
  • In this paper, we analyze the errors associated with magnetic field interference for fiber-optic current sensors working in a three-phase electric system and provide a solution to compensate the interference. For many practical conductor arrangements, the magnetic filed interference may cause errors unacceptable for the accuracy requirements of the sensors. We devised a real time compensation method for the interference by introducing geometric and weight factors. We realized the method using simple electronic circuits and obtained the real time compensated outputs with errors of ${\pm}1%$.

Electromagnetic Forces Measurement of Various Electric Appliances and Places (각종 전기기기 및 장소에서의 전자파 측정)

  • Kim, Deok-Won;Ryu, Chang-Yong;Kim, Su-Chan;Yoon, Hyung-Ro
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.179-182
    • /
    • 1995
  • Although air, water, and noise pollutions have been widely recognized, electromagnetic forces(EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, once machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven senates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

  • PDF

Measurement and Analysis of Electric and Magnetic Fields near 345[kV] Transmission Tower (345[kV] 송전철탑 주변에서 전장과 자장의 측정과 분석)

  • 이복희;이승칠;안창환;길형준;전덕규;길경석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.14-21
    • /
    • 1998
  • In this paper, the measurements of ELF electric and magnetic fields due to double circuit 345[kV} transmission lines are made using planar-type electric field sensor and multitum loop-type magnetic field sensor, and the magnitudes of electric and magnetic fields are illustrated by a three-dimensional plot. Also, in order to predict the magnetic field strength with lad variation, a typical daily load current curves of the transmission lines are displayed because the magnetic field is changed with load current. experimental results of ELF electric and magnetic fields along center line versus lateral distance are compared with the theoretical values computed by using the FIELDS program. The electric field intensity in and around a transmission tower is lowered, and the greatest point of the magnetic field is shifted to the heavy load line but generally is given the trend that the peak value appear at the central part of the transmission tower. The magnitudes of the maximum electric and magnetic fields in the vicinity of a transmission tower are less than 3.5[kV/m] and $20[{\mu}T]$, respectively. The measured electric and magnetic fields are satisfied with limits and guidelines recommended by various authorized international institutes.

  • PDF

Measurement of Nonlinear Dielectric Constant (비선형 유전율의 측정)

  • Roh, I.S.;Kang, D.H.;Lee, S.U.;Heo, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1331-1333
    • /
    • 2001
  • In this study a measurement equipment was designed and made for the nonlinear dielectric constants in dielectrics. The determining method of the nonlinear dielectric constants also was proposed. The measurement equipment was consisted of the wave generation part, the high voltage amplifier part, the measurement part and the data acquisition part. In this equipment the measurement control and the data processing could be conducted by computer. In order to determine the nonlinear dielectric constants alternating sign-wave electric fields are applied to dielectrics with different magnitude and the waves of the electric fields and the response from dielectrics are stored in computer memories. The harmonics of dielectric displacement are obtained by the Fourier transformation of these waves. The nonlinear dielectric constants are determined at the relatively low-field region. The experiment for PZT ceramic samples was done by the equipment and the determining method and as the result meaningful data were obtained.

  • PDF