• Title/Summary/Keyword: electric field measurement

Search Result 455, Processing Time 0.03 seconds

The Measurement of Electromagnetic Waves caused by Surface Discharges of Solide Insulator at VHF Band Using an Antenna (안테나를 이용한 VHF대역에서 고체절연체의 연면방전에 기인한 방사전자파의 측정)

  • Kim, Ch.N.;Park, K.S.;Kim, K.C.;Lee, K.S.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.219-223
    • /
    • 2001
  • In this paper, electromagnetic waves were measured in accordance with propagating the discharge when positive and negative DC high voltage was applied to needle-plane electrdes and plane-plane electrdes that solid dielectric was inserted between the electrodes. The radiated electromagnetic waves were investigated in bandwidth of VHF($30{\sim}230$[MHz]) using an biconical antenna. In needle-plane electrodes high electric field intensity is shown in both frequency band of 90(MHz) and 170[MHz], and gradually decreasing characteric is appeared at high frequency band. However high electric field intensity is shown in both 80[MHz] and 140[MHz] in case of plane-plane electrodes configuration. And over 150[MHz] frequency band, rapidly decreasing characteristic is shown. Moreover, electric field intensity of positive DC is about $5{\sim}10$[dB] higher than negative DC.

  • PDF

Fabrication and Evaluation of AC 400 kV High Voltage Divider using Electric Field Sensor (전기장 센서를 이용한 교류 400 kV 고전압 분압기의 제작 및 평가)

  • Lee, Sang-Hwa;Han, Sang-Gil;Jung, Jae-Kap;Kang, Jeon-Hong;Kim, Yoon-Hyoung;Jeong, Jin-Hye;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.265-269
    • /
    • 2008
  • Output voltage value of AC high voltage source has usually been obtained by measuring the low arm voltage of high voltage divider or the secondary voltage of high voltage transformer. In this study, we have fabricated the AC 400 kV high voltage divider using high voltage electrode and electric field measurement sensor. The dividing ratio of the fabricated 400 kV high voltage divider was evaluated using reference 400 kV capacitive divider. The dividing ratio of 400 kV high voltage divider is found to be 12,322 and has the good linearity within 0.63 % against AC high voltage up to 400 kV. Therefore, the developed 400 kV high voltage divider could evaluate 400 kV high voltage supply and voltage divider used in industry.

The Characteristics of Electric Field Distributions in a Reverberation Chamber using Cylindrical Diffuser (원통형 확산기를 사용한 전자파 잔향실내의 전기장 분포특성)

  • Lee, Yong;Rhee, Joong-Geun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.8
    • /
    • pp.121-127
    • /
    • 2008
  • This paper presents an electric field distribution in a reverberation chamber using cylindrical diffuser. The characteristics of electric field distributions are compared with QRD(Quadratic Residue Diffuser) and cylindrical diffuser for $1{\sim}3$ GHz frequency band. The FDTD(Finite-Difference Time-Domain) method is used to analyze the field characteristics, and the field uniformity. At 2 GHz, the standard deviation and the tolerance of test volume in the reverberation chamber are improved by 0.11 dB, 0.43 dB for the case of cylindrical diffuser. The field strength is increased by 43.2 dBmV/m vs QRD's of 36.6 dBmV/m. Comparing with QRD's, the characteristic of polarization is also improved. These results show that reverberation chamber using cylindrical diffuser can be used alternative facility for measurement of electromagnetic interference and immunity.

A study on measurement apparatus for ferroelectricity in ferroelectrics (강유전특성 측정장치의 연구개발)

  • Lee, Chang-Hun;Kang, Dae-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1317-1319
    • /
    • 1997
  • This paper is to study and develope a measurement apparatus for ferroelectricity. The apparatus consists of wave generation part, high voltage amplifier part, measurement part, data acquisition part and the related controll circuits. Single or double excitation wave is digitalized and sent to the external RAM of wave generation part by personal computer. These datas saved in the RAM are converted to analog excitation wave through D/A converter. The frequency of excitation wave is depend on the read-out speed of the RAM by clock pulse. Such generated wave is applied to high voltage amplifier as a input voltage. The output of high voltage amplifier is applied to ferroelectrics and the response is obtained from the charge amplifier of measurement part. The response is sampled and converted to digital datas through AID converter. These digital datas are automatically saved in the external RAM of acquisition part. The computer takes the digital datas and calculates the electric displacement D, the electric field and the dielectric constant $\varepsilon$. We tested for PZT ceramic sample and could observed the D-E hysteresis lops and ${\varepsilon}_s$-E hysteresis loops with good forms.

  • PDF

DESIGN AND PRELIMINARY TEST RESULTS OF MAGNETOMETERS (MAG/AIM & SIM) FOR SOUNDING ROCKET KSR-III (KSR-III 과학 관측 로켓 자력계(MAG/AIM & SIM)의 초기 시험 모델 개발)

  • KIM HYO-MIN;JANG MIN-HWAN;SON DE-RAC;LEE DONG-HUN;KIM SUN-MI;HWANG SEUNG-HYUN
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc2
    • /
    • pp.57-64
    • /
    • 2000
  • It is realized that the extraterrestrial matter is in ionized state, plasma, so the matter of this kind behaves as not expected because of its sensitiveness to electric and magnetic fields and its ability to carry electric currents. This kind of subtle change can be observed by an instrument for the magnetic field measurement, the magnetometer usually mounted on the rocket and the satellite, and based on the ground observatory. The magnetometer is a useful instrument for the spacecraft attitude control and the Earth's magnetic field measurements for the scientific purpose. In this paper, we present the preliminary design and the test results of the two onboard magnetometers of KARl's (Korea Aerospace Research Institute) sounding rocket, KSR­III, which will be launched during the period of 2001-02. The KSR-III magnetometers consist of the fluxgate magnetometer, MAG/AIM (Attitude Information Magnetometer) for acquiring the rocket flight attitude information, and of the search-coil magnetometer, MAG/SIM (Scientific Investigation Magnetometer) for the observation of the Earth's magnetic field fluctuations. With the MAG/AIM, the 3-axis attitude information can be acquired by the comparison of the resulting dc magnetic vector fields with the IGRF (International Geomagnetic Reference Field). The Earth's magnetic field fluctuations ranging from 10 to 1,000 Hz can also be observed with the MAG/SIM measurement.

  • PDF

Development of Contaminant Leakage Detection System Using Electrical Resistance Measurement: ll. Evaluation of Applicability for Landfill Site by Field Model Tests (전기저항 측정기법을 이용한 오염물질 누출감지시스템의 개발: II. 현장모형시험을 통한 매립지에의 적용성 평가)

  • 오명학;이주형;박준범;김형석;강우식
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.225-233
    • /
    • 2001
  • Field model tests were performed to develop the grid-net landfill leachate leakage detection system using electrical resistance. Electric circuit tests were also carried out to investigate the expected electrical effects of grid-net electric circuit. The resistance of leaking point showed lower value than that of non leaking point. Grid-net leakage detection system was thought to be effective to locate the leachate leaking point. The measured electrical resistance along the wire including the leaking point was slightly reduced following the reduction of electrical resistance at the leaking point, which was explained by electric circuit test results.

  • PDF

Environmental effects by corona discharge from a 765kV double circuit transmission line (765kV 2회선 송전선의 코로나 방전에 의한 환경영향 연구)

  • 김정부;이동일;신구용;양광호;안희성;구자윤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.451-455
    • /
    • 1996
  • This paper specified the measurement results conducted by the Korea Electric Power Research Institute (KEPRI) 765kV double circuit transmission test line that measured the audible noise, hum noise, radio interference, electric field and aeolian measurement. This test line consists of 6-480mm$^{2}$ conductors per phase. The analysis of the test results shows that this 6-Rail conductor bundle satisfies the audible noise criterion under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion. (author). 9 refs., 7 figs., 2 tabs.

  • PDF

Comparison of the Poor Insulator Detecting Technique for the Reliability Enhancement of the Electric Power Facilities (전력설비의 신뢰성 향상을 위한 불량애자검출기법의 비교)

  • Jung, Soon-Won;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.417-423
    • /
    • 2008
  • For the evaluation in the safety of outdoor insulator, there are various methods such as: visual observation; voltage measurement; use of ultrasonic wave due to partial discharge; electric field measurement; use of infrared/ultraviolet sensor-type camera. However, many problems have been issued regrading the reliability of the evaluation test and safety of testing operation. Accordingly, the present study has investigated and analyzed the characteristics and mechanisms of the insulator deterioration, in order to obtain an optimal method for detecting poor insulator so that the reliability of power facilities can be enhanced. Besides, based on theoretical analysis of domestic and international detection methods for poor insulator, the reliability has been compared and evaluated quantitatively. As a result, it was shown that the corona camera would be the best choice for domestic workplace application in detecting poor insulator for enhancing the reliability of power transmission line.

On the Method of Measuring the Mobility using the Microwave by the Hall Effect in the semiconductor (마이크로파를 이용하여 반도체내의 Hall에 의한 이동도측정방법)

  • 허영남
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.8 no.2
    • /
    • pp.54-62
    • /
    • 1983
  • The electric characteristics of semiconductor materials can be found by way of various methods, of which the measurement of the carrier mobility is thought to be of great importance. There exist some mobilty measurements, but the measurement based on Hall effect is the most widely uesd. In this paper is adopted the mobility measurement of semiconductor by the use of cylindrical eavity operated in the same shape as TE modes. It is hoped that the resultant values of measurement, the structure of measurement circut, cavity design and the raising of relevant problems may give much help to those who may interested in this field.

  • PDF

The Standard of test and evaluation for HTS cable system (고온 초전도 케이블 시스템 시험 및 평가 기준(안))

  • Choi, Hyung-Sik;Hwang, Si-Dole;Sohn, Song-Ho;Lim, Ji-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.490-491
    • /
    • 2006
  • Based on the real field test of 22.9kV HTS cable, which is installed in Gochang Power Testing Center located in Chonbuk Province, the standard for the performance test and the quality evaluation have been established. This work will be applied to the development of HTS cable and the purchase process as a practical material. In particular, new items for the cable evaluation such as the measurement of critical current and the heat loss, which was not dealt with in conventional cable, are specified in detail.

  • PDF