퓨즈가 내장된 엘보접속재의 설계 (Design of Fuse Mounted Elbow Connector)

  • 최경선;이철호;송일근;권태종;권영복;한명관
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.383-386
    • /
    • 2000
  • Fuse mounted elbow connector used for pad mounted transformer was designed and investigated. Requirements of electrical ratings such as partial discharge, ac withstand voltage and impulse voltage and material properties were proposed in accordance with IEEE 386 and pre-standard (PS) 147-219∼229 of KEPCO. The connector can be jointed with pad mounted transformer and current limiting fuse which is installed inside of the connector easily replaced with new one in the case of breakdown of the fuse. Electric field analysis was also introduced in other to verify the reliability of the design.

  • PDF

평면배열 커넥터 터미널 핀에 오목형상 부여가 접압력 향상에 미치는 영향에 관한 연구 (A Study on the Effects of Concave Shaping in Improving Contract Pressure for Planar Array Connector Terminal Pins)

  • 전용준;신광호;허영무
    • Design & Manufacturing
    • /
    • 제10권1호
    • /
    • pp.36-40
    • /
    • 2016
  • Connectors transmit electric signals to different parts in compact mobile display products. As products that apply this have become lightweight and smaller in size, there are growing demands for smaller and more integrated connectors, which are internal parts of the products. As a measure to address these demands, there is the planar array connector that minimizes the part by arranging the single-direction BTB connectors to two directions. As connectors become smaller in size and more highly integrated, maintaining intensity to prevent defects during impact and maintaining adhesive force to smoothly transmit electric signals are growing in importance. Thus, in order to identify the impact of concave shaping on improving adhesive power in connector terminal pins as a method to increase the connecting power of planar array connector terminal pins, this study predicted and examined the concave shaping method, number of concave shapes, and the adhesive power according to the size of the concave shape through CAE. For concave shaping, the model that added concave shaping towards the lower part of the connector terminal pin and added spokes for the area pressed down by the concave shaping was 0.74 N, showing increased adhesive force compared to existing models. Furthermore, when applying two concave shaping, rather than just one, there was a tendency for adhesive force to increase. In the case of adhesive power trends according to the size of the concave shaping, adhesive power increased and the width of the concave shape decreased, and the biggest adhesive force trends were shown when the concave shaping depth was 0.01mm.

전차선로시스템의 순환전류에 대한 안정성 향상에 관한 고찰 (Considerations in the reliability improvement against Circulation Current in the Catenary System for Electirc Railway of Korea)

  • 김인철;강승욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.24-26
    • /
    • 2006
  • In these days, Korea Railway apply simple catenary system to general lines and high speed lines of Korea Electric Railway. Circulation Current in catenary system frequently bring undesirable consequences. Namely, the Connector wire has many problems according to a flow of excessive circulation (or traction current) and a sudden rise of temperature on catenary when electric car or locomotive is running in high speed. The occurrence of events by the load increasement do considerable damages to peoples, organizations and systems. In this paper, we proposed the improved changes on the catenary system of a improvement and change of a messenger wire protector, improvement of connector wire,s institution angle and of a replacement the connector wire with a dropper. A case of Circulation Current continually has broken out in Yongdungpo Electric Office's own bailiwick. By or through the medium of these obstacles, we have further use of many studies and considering countermeasures. Therefore, we have to deal with the question in design and execution of catenary system for High Speed Railway because we will spend a lot of time and more money for maintenance than for construction of that.

  • PDF

휠체어 전동주행 보조기기용 커넥터의 구조안정성 해석 (Structural Stability Analysis of Connectors for an Electric Handbike)

  • 서한울;김대동;고철웅;이준흠;배태수
    • 한국정밀공학회지
    • /
    • 제32권5호
    • /
    • pp.491-496
    • /
    • 2015
  • Electric handbike can be easily detachable to various sizes of manual wheelchair and the elderly and people with disabilities can use them easily. Therefore, connectors used for coupling between the handbike and manual wheelchair must secure structural stability for occupant safety. However, related research is rare. The aim of this study is to find the connector with highly structural stability by comparing static and dynamic mechanical characteristics among three typical connectors(a snatch lock, a slide latch, and a fastener) by computational simulations. To perform static and dynamic simulation, we referred to durability test based on Korean Standards and then calculated mechanical stresses in connectors. The results showed that the snatch lock addressed the lowest von-mises stress under the same mechanical condition. Therefore when using the combination of a handbike and a wheelchair, we concluded that the snatch lock is considered as the structurally stable connector to structural stability and usability.

ABS 모듈의 접속부 및 전원배선 손상으로 인한 차량화재 사고사례 분석 (Analysis on the Fire Accident of Vehicle Due to Damage of Connector and wiring on an Anti-lock Brake System(ABS) Module)

  • 박남규;김진표;남정우;박종택;송재용
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.13-19
    • /
    • 2017
  • In this paper, study of vehicle fire cases caused by connector and power wiring of anti-lock brake system(ABS) module damage is presented. The purpose of ABS module is to improve braking and steering ability under sudden stop of the vehicle by repeatedly activating and releasing the brake with electric signal via electric control unit. The electric control unit for ABS may experience incomplete contact between power line and signal line or electrical breakdown on the printed circuit board by undergoing repetitive signal change which would consequently result in electrical heat and spark, eventually leading to automotive fire. Therefore, the purpose of this paper is to provide fundamental data by analyzing connector and power wiring of ABS module damage conducive to the precise investigation on the cause of vehicle fire.

가속수명 시험을 이용한 자동차용 커넥터의 신뢰성 분석 (Reliability Analysis of Auto-Connector based on Accelerated Life Test)

  • 김종걸;김진환
    • 한국품질경영학회:학술대회논문집
    • /
    • 한국품질경영학회 2004년도 품질경영모델을 통한 가치 창출
    • /
    • pp.261-265
    • /
    • 2004
  • As a car is a combination of a lot of components, it is necessary to consider safety and durability. Even there are lots of components for a car, the connector is one of the most important one since it connects functional electric signal. Usually automotive connector is tested under each car maker's test specification, which should have dependability characteristic. In this paper, we aim to review the current test specifications in view of dependability, and propose an accelerated life test for the automotive connector.

  • PDF

Electrical Impedance Change due to Contamination at the Contact Interface of Connectors for Automobile Crank Shaft Position Sensor

  • Kim, Young-Tae;Sung, In-Ha;Kim, Dae-Eun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권2호
    • /
    • pp.46-52
    • /
    • 2004
  • Numerous connectors are used in automobiles for transmission of electrical signals across various electro-mechanical components. The connectors must operate with high reliability in order to minimize failures due to signal degradation. In this work, the effects of contamination at the contact interface of connectors used fur automobile crankshaft position sensor on the impedance change were investigated. An experimental set-up was built to simulate the electrical signal transmitted from the sensor to the engine control unit through a connector. Output from the connector was investigated using connectors contaminated with engine block residues and water droplets. It was found that slight contamination of the connectors could lead to significant signal degradation which can lead to engine failure. Also, the effect of water in the connector altered the signal severely. However, the signal gradually regained the original state as the water evaporated from the interface.

일정 변위 진폭조건에서의 은도금한 커넥터의 미동마멸부식 거동 (Fretting Corrosion Behavior of Silver-Plated Electric Connectors with Constant Displacement Amplitude)

  • 오만진;김민정;김택영;강세형;김호경
    • Tribology and Lubricants
    • /
    • 제30권2호
    • /
    • pp.99-107
    • /
    • 2014
  • Fretting corrosion tests are conducted with a constant displacement amplitude using silver-plated brass coupons to investigate the effect of contact pressure on fretting corrosion. Three behaviors are identified based on the change in electric resistance and friction coefficient during the fretting test period, and the identified behaviors are dependent on the magnitude of the applied load. The failure cycle ($N_f$) with an electric resistance of 0.1 D cannot be achieved due to the adhesion behavior of the metal and metal contact under the higher applied load of 0.45 N. This suggests that an average contact pressure higher than 159 MPa for the silver-coated connector is desirable to gain an almost infinite lifetime. The relationship between the electric contact resistance (R) and the average contact pressure (p) can be written as $p=106.2{\times}{\Omega}^{-1.5}$.

5.5kW이하의 소형분쇄기 차단기 접속부의 접촉불량에 의한 전압강하 및 열적 특성 분석 (Analysis of Voltage Drop and Thermal Characteristics for Poor Connections at Electrical Connector of Circuit Breaker of Small Size Pulverizer below 5.5kW)

  • 김상철
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.26-31
    • /
    • 2015
  • This paper describes the characteristics of voltage drop and thermal for poor connection on electrical connector of circuit breaker in control box of small size pulverizer. In order monitor, we did the changes of RMS in voltage and temperature value with video and made normal state over $2.5N{\cdot}m$ and poor connections state below $0.2N{\cdot}m$ by screw gage. In case of voltage signal, the voltage drop was increased when the current was increased due to poor connections. In case of temperature signal, the temperature difference indicates ten times at 5A and fourteen times at 15A in the normal state. According to increase thermal energy, the insulation of electrical wiring and connector of circuit breaker can be carbonized. The results of this study will be useful to the development of preventive devices and system for electric fire by poor connection at small size pulverizer.