• Title/Summary/Keyword: electric arc furnace

Search Result 189, Processing Time 0.03 seconds

A Study of Harmonics by Arc Furnace Operating for Demand Side Management (수요관리를 위한 아크로 운전 상태에 따른 고조파 연구)

  • Park, Kyung-Ho;Kim, Jae-Chul;Park, Hyun-Teak;Im, Sang-Kug;Oh, Dong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.17-19
    • /
    • 2003
  • Electric arc furnace has consumed plenty of power. Hence electric arc furnace can be expected to use for demand side management. When electric arc furnace use for demand side management, electric arc furnace frequently occur a starting and a stop. Electric arc furnace irregularity change consumption of power. Due to character of time-varing and non-linear, electirc arc furnace has a problem with voltage quality(flicker, harmonics). Producted harmonic in electric art furnace is different any harmonic source because of electric arc furnace peculiar operating. Accordingly, analysis for generated harmonic in electric arc furnace operating is demanded. This paper analyze effect of harmonic by arc furnace operating.

  • PDF

Properties of Blast Furnace Slag Cement Modified with Electric Arc Furnace Slag (전기로 슬래그를 치환한 고로 슬래그 시멘트의 특성)

  • Lee, Seung-Heun;Hwang, Hae-Jeong;Kwon, Sung-Ku
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.7 s.290
    • /
    • pp.408-414
    • /
    • 2006
  • Properties of slag cement that contained 50 wt% of blast furnace slag were studied when replaced blast furnace slag powder with electric arc furnace slag powder. Electric arc furnace slag was aged for about 2 months in the air by being crushed to be 1-3 mm in size. As a result of the experiment, it was proven that the water content for obtaining the same consistency became decreased as slag is replaced with electric arc furnace slag instead of blast furnace slag. Also, the workability of mortar increased about 30% at the same ratio of water to binder when blast furnace slag was completely replaced with electric arc furnace slag. The compressive strength of mortar on the 28 days increased when a slag replacement rate became 10 wt%, however, it rather decreased when the slag replacement rate exceeded 10 wt%. The heat of hydration became higher for the first 14 h in case of the replacement of slag cement by electric arc furnace slag. Yet, it decreased when 14 h had passed. Therefore, when all blast furnace slag was replaced with electric arc furnace slag, about 15 cal/g heat of hydration decreased when it passed about 72 h.

A Study on Radiation Shielding Performance of Radiation Shielding Concrete Utilizing Electronic arc Furnace Oxidizing Slag (전기로 산화슬래그 골재를 활용한 방사능차폐콘크리트의 방사능 차폐 성능에 관한 연구)

  • Lim, Hee-Seob;Lee, Han-Seung;Choi, jae-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.243-244
    • /
    • 2011
  • In general, magnetite or barite (density: more than 4.0ton/㎥) has been used in concrete for radiation shielding, and radiation tests have been performed to evaluate shielding performance. However, researchers have not studied concrete for radiation shielding that utilizes electric arc furnace oxidizing slag. This research aims to utilize electric arc furnace oxidizing slag which depends on reclamation as environment-friendly concrete materials by using coarse and fine aggregates of electric arc furnace slag containing 30% ferrous metal and with a density of around 3.0~3.8 ton/㎥. Accordingly, this research has judged that the high density electric arc furnace oxidizing slag aggregate can be applied to radiation shielding concrete. It has also examined the possibility of developing radiation shielding concrete utilizing electric arc furnace oxidizing slag aggregate by comparing concrete utilizing all fine and coarse aggregate of electric arc furnace oxidizing slag with concrete using magnetite.

  • PDF

Comparison of X-ray Shielding Performance according to the Weight of unit volume of Heavy Weight Concrete Utilizing Electric Arc Furnace Oxidizing Slag. (전기로 산화슬래그 골재를 활용한 중량 콘크리트의 단위 용적 중량 변화에 따른 X-선 차폐 성능 비교)

  • Lim, Hee Seob;Lee, Han Seung;Choi, jae Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.35-36
    • /
    • 2013
  • Electric arc furnace oxidizing slag from massively produced steel slag has been used in road bases and subbases, hot mix asphalt, and landfill. Electric arc furnace oxidizing slag contains iron (15%~30%) and has a high density of 3.0~3.7 ton/m3. Depending on the type and amount of concrete aggregates, the radiation-shielding characteristics can vary. Therefore, aggregates of electric arc furnace oxidizing slag can be considered for the production of radiation-shielding concrete. The experimental design of this study is experiments on Compressive strength experiments, X-ray irradiation experiments, and experiments related to the unit volume weight were carried out on hardened concrete. This experiment compared the performance evaluation of radiation shielding of concrete using electric arc furnace oxidizing slag.

  • PDF

NUMERICAL ANALYSIS OF AN ARC PLASMA IN A DC ELECTRIC FURNACE

  • Lee Yeon Won;Lee Jong Hoon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.30-33
    • /
    • 2004
  • In order to analyze the heat transfer phenomena in the plasma flames, a mathematical model describing heat and fluid How in an electric arc has been developed and used to predict heat transfer from the arc to the steel bath in a DC Electric Arc Furnace. The arc model takes the separate contributions to the heat transfer from each involved mechanism into account, i.e. radiation, convection and energy transported by electrons. The finite volume method and a SIMPLE algorithm are used for solving the governing MHD equations, i.e., conservation equations of mass, momentum, and energy together with the equations describing a standard $k-\varepsilon$ model for turbulence. The model predicts heat transfer for different currents and arc lengths. Finally these calculation results can be used as a useful insight into plasma phenomena of the industrial-scale electric arc furnace. from these results, it can be concluded that higher arc current and longer arc length give high heat transfer.

  • PDF

Utilization of Electric Arc furnace Slag md Converter Slag after Aging for Concrete Aggregate (콘크리트용 골재로서 에이징처리한 제강슬래그외 활용)

  • 문한영;유정훈
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.597-607
    • /
    • 2002
  • Electric arc furnace and converter slag are produced by about 6 millions tons in Korea at 2000 year. But compared with blast furnace slag, those are utilized only in unvalued material like landfill and road construction. There are unstable materials, like free CaO, in electric arc furnace and converter slag at steel-manufacturing process. This might cause volume expansion in concrete, if electric arc furnace and converter slag aggregates were used in concrete. This expansion may reach to crack or collapse of concrete. It is therefore settled by standard specification for concrete that electric arc furnace and converter slag aggregates have not to use in concrete. First of all, volume stability and stabilized process should be solved in electric arc furnace and converter slag aggregate to use in concrete. In this study, 6 types of aging are evaluated for effects of stabilization to reduce the expansion of electric arc furnace and converter slag. h converter slag aggregate, these types of aging are not good for volume stability for concrete aggregate, and even if converter slag aggregate is treated with aging, concrete with it has some problems that strength is reduced with curing days. But in electric arc furnace slag aggregate treated with hotwater and steam aging, the expansion of electric arc furnace slag aggregate is reduced about two times than that of converter slag aggregate, and electric arc furnace slag aggregate concrete has good results in strength compared with control concrete using crushed stone.

A Study on the EMP Shielding and Physical Properties of Concrete using Electric Arc Furnace Oxidizing Slag aggregate (전기로산화슬래그 골재를 사용한 콘크리트의 EMP 차폐 및 물리적 특성에 관한 연구)

  • Min, Tae-Beom;Lee, Min-Seog;Kim, Hyeong-Cheol;Kim, Jae-Young;Choi, Hyun-Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.177-178
    • /
    • 2020
  • The EMP slip rate was compared with the general concrete using the electric arc furnace slag as an aggregate. Experimental results show that the shielding rate of concrete specimens using electric arc furnace slag increases. It is considered that the shielding rate is increased due to the high Fe content in the components of the electric arc furnace slag aggregate.

  • PDF

A Study on Kinetic of Volatilization Behavior of Metal Elements Contained in Electric Arc Furnace Dust (전기로 제강분진에 함유된 금속원소의 휘발거동에 대한 속도론적 연구)

  • Yoon, Jaehong;Yoon, Chihyun;Lee, Myungwon
    • Resources Recycling
    • /
    • v.26 no.3
    • /
    • pp.17-25
    • /
    • 2017
  • Electric arc furnace steelmaking dust has various physicochemical properties as volatile components generated in the melting process of steel scraps in an electric arc furnace, which is captured in oxide form as fine powder by reacting with oxygen in the air. In order to efficiently recycle these electric arc furnace dust, a kinetic basic experiment and a pilot production test were carried out in parallel. As a result, it was found that the electric arc furnace dust contain a large amount of Cl and alkali components, thus it was expected that the compounds have a great adverse effect on the actual operation for the recycling. It was confirmed that the volatilization behavior was progressing actively at $1100^{\circ}C$ and the electric arc furnace dust was melted at $1250^{\circ}C$. These results are the same as a result of pilot test for the formation behavior of zinc oxide and reduced iron. These results should be useful as basic data for designing the recycling plant of the electric arc furnace dust and establishing the operating conditions.

Harmonics Analysis for Electric Arc Furnace According to the Operation Condition (전기 아크로 운전 상태에 따른 고조파 해석)

  • Kim, Jae-Chul;Park, Kyung-Ho;Park, Hyun-Teak;Moon, Jong-Fil;Im, Sang-Kug;Son, Hag-Sig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.118-125
    • /
    • 2004
  • The use of electric arc furnace has been increasing as the steel consumption is increasing and the operation technique of electric arc furnace are developing. But as the use of electric arc furnace is increased, the furnace have produced the adverse effects of power quality: voltage and current harmonics, voltage and current imbalances, low power factor, and voltage flicker. One of the power quality problems, the harmonic have the characteristics of the time-varying and non-linear. This paper analyzed the harmonics for the various operation conditions of electric arc furnace. The power system model with electric arc furnace have been made, and the harmonic's effects on the power system has been analyzed according to the various operating conditions, first melting, second melting, so on. Also, the filter reducing the harmonic components have been designed and its effects on the power system have been examined.

Numerical Analysis on Plasma Characteristics of a DC Electric Arc Furnace (직류 전기 아크로에서의 플라즈마 특성에 관한 수치해석)

  • Lee J. H.;Han B. Y.;Kwak S. M.;Lee Y. W.;Kim C. W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.212-218
    • /
    • 2003
  • In order to analyze the heat transfer phenomena in the plasma flames, a mathematical model describing heat and fluid flow in an electric arc has been developed and used to predict heat transfer from the arc to the steel bath in a DC Electric Arc Furnace. The arc model takes the separate contributions to the heat transfer from each involved mechanism into account, i.e. radiation, convection and energy transported by electrons. The finite volume method and a SIMPLE algorithm are used for solving the governing MHD equations, i.e., conservation equations of mass, momentum, and energy together with the equations describing a $\kappa-\epsilon$ model for turbulence. The model predicts heat transfer for different currents and arc lengths. Finally these calculation results can be used as a useful insight into plasma phenomena of the industrial-scale electric arc furnace. From these results, it can be concluded that higher arc current and longer arc length give high heat transfer.

  • PDF