• Title/Summary/Keyword: ejection fraction

Search Result 346, Processing Time 0.027 seconds

Analysis of Myocardial Function Using Gated Myocardial SPET : Comparison of QGS, 4D-MSPECT Software and Echocardiography (게이트 심근관류 SPECT를 이용한 심기능 분석: 정량분석 소프트웨어 QGS, 4D-MSPECT 및 심초음파법의 비교)

  • Lee, Seok-Mo;Bae, Sang-Kyun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.435-443
    • /
    • 2008
  • Purpose: Gated myocardial perfusion SPECT provides not only myocardial perfusion status but also various functional parameters of left ventricle. We compared left ventricular ejection fraction, end-diastolic volume, LV mass by cardiac SPECT using Quantitative Gated SPECT (QGS), 4D-MSPECT software and standard 2D-echocardiography. Materials and Methods: One hundred fourteen patients (male 51, female 63; 29-85 years old, mean $61.3\;{\pm}\;13.3$ years old) with normal perfusion status on Tc-99m tetrofosmin gated myocardial perfusion SPECT were analyzed retrospectively. Ejection fraction (LVEF), End-diastolic volume (LVED), LV mass (LVM) were calculated using QGS, 4D-MSPECT, and LVEF, LVM using 2D-echocardiography. Statistical analysis including Bland-Altman plot was performed using $MedCalc^{(R)}$ (MedCalc software, Mariakerke, Belgium). Results: The correlation of LVEF between methods was good: 0.95/0.96 (stress/rest) between QGS and 4D-MSPECT, 0.79 between QGS and echocardiography, 0.79 between 4D-MSPECT and echocardiography (p<0.001). Using Bland-Altman plot, the 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -12.7% to 7.3% / from -12.2% to 6.5% (stress/rest). The agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -17.4% to 24.0%, and -14.8% to 27.0% respectively. The correlation of LVM between methods was also good: 0.95 between QGS and 4D-MSPECT, 0.76 between QGS and echocardiography, 0.73 between 4D-MSPECT and echocardiography (p<0.001). The 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -33.8g to 14.1g (stress/rest), The 95% confidence interval of agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -148.7 g to 21.8. g, and -142.8 g to 35.5 g, respectively. Conclusion: There was a good correlation for LVEF, LVEO, LVM among methods (QGS, 4D-MSPECT, echocardiography), but the variance between methods was big. Therefore, the functional parameters by each method cannot be used interchangeably.

Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques (조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가)

  • Nam, Ji-Ho;Ki, Yong-Kan;Kim, Dong-Won;Kim, Won-Taek
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.26-33
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The aim of this study is to evaluate and compare the incidence and aspects of myocardial perfusion defects in patients who were subjected to either two-dimensional or three-dimensional simulation techniques for early left-sided breast cancer. The myocardial perfusion defects were determined from using single photon emitted computerized tomography (SPECT) myocardial perfusion images. $\underline{Materials\;and\;Methods}$: Between January 2002 and August 2003, 32 patients were enrolled in this study. The patients were diagnosed as having early (AJCC stage T1-T2N0M0) left-sided breast cancer and were treated with tangential irradiation after breast-conserving surgery and systemic chemotherapy. The patients were divided into two groups according to the type of simulation received: two-dimensional simulation using an X-ray fluoroscope simulator or three-dimensional simulation with a CT simulator. All patients underwent technetium-99m-sestamibi gated perfusion SPECT at least 3 years after radiotherapy. The incidence and area of myocardial perfusion defects were evaluated and were compared in the two groups, and at the same time left ventricular ejection fraction and cardiac wall motion were also analyzed. The cardiac volume included in the radiation fields was calculated and evaluated to check for a correlation between the amount of irradiated cardiac volume and aspects of myocardial perfusion defects. $\underline{Results}$: A myocardial perfusion defect was detected in 11 of 32 patients (34.4%). There were 7 (46.7%) perfusion defect cases in 15 patients who underwent the two-dimensional simulation technique and 4 (23.5%) patients with perfusion defects in the three-dimensional simulation group (p=0.0312). In 10 of 11 patients who had myocardial perfusion changes, the perfusion defects were observed in the cardiac apex. The left ventricular ejection fraction was within the normal range and cardiac wall motion was normal in all patients. The irradiated cardiac volume of patients in the three-dimensional simulation group was less than that of patients who received the two-dimensional simulation technique, but there was no statistical significance as compared to the incidence of perfusion defects. $\underline{Conclusion}$: Radiotherapy with a CT simulator (three-dimensional simulation technique) for early left-sided breast cancer may reduce the size of the irradiated cardiac volume and the incidence of myocardial perfusion defects. Further investigation and a longer follow-up duration are needed to analyze the relationship between myocardial perfusion defects and clinical ischemic heart disease.

Simple and Effective Surgical Repair with Vascular Graft Strip for Ischemic MR (인조혈관대를 이용한 허혈성 승모판막 폐쇄부전의 수술적 치료)

  • 민호기;이승훈;이주현;성기익;박계현;전태국;박표원;이영탁
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.646-650
    • /
    • 2003
  • Many surgical techniques for ischemic mitral regurgitation (IMR) have been used with their excellent results and advantages. Here, we report our simple posterior annuloplasty techniques using vascular graft strip with their early results. Material and Method: Twenty two patients (13 male) underwent the operations for IMR (excluding the papillary muscle rupture) from December 2001 to January 2003. Preoperative risk factors were low ejection fraction (<35%, n=9), hypertension (n=13), diabetes (n=9), and renal failure (Cr>2.5, n=4). The wide dissection beneath the both vena cavae and interatrial groove after bicaval cannulation enabled the easy exposure of mitral valve even in the small left atrium. After eight or nine interrupted sutures in posterior annulus for anchoring the 6 mm width vascular graft strip, symmetric (n=8) or asymmetric (n=14) annuloplasty were done. Combined surgeries were CABG (n=21), Dor procedures (n=3), tricuspid valve annuloplasty (n=1), Maze operation (n=1), and aorto-right subclavian artery bypass (n=1). Result: Except for one surgical mortality, all the patients were doing well and the mean grade of regurgitation was decreased from 2.95 to 0.88, however the ejection fraction had not changed significantly just before discharge. Post-operative valve function evaluated before discharge revealed no residual regurgitation in 8 (including 1 patient with mild stenosis due to over reduction), minimal in 11, mild in 2, and mild to moderate regurgitation in 1. One patient who had ischemic cardiomyopathy and renal failure died of the arrhythmia during the hemodialysis. Conclusion: These observations suggest that the annuloplasty with vascular graft strip could be a safe and cost effective techniques for ischemic mitral regurgitation. However, the long term evaluation for the mitral valve function should be defined for the final conclusion.

Establishment of the Heart Failure Model in Swine for the Experiment of the Pneumatic Ventricular Assist Device (공압식 심실보조기의 실험을 위한 돼지에서의 심부전 모델의 개발)

  • 박성식;서필원;이상훈;강봉진;문상호;김삼현
    • Journal of Chest Surgery
    • /
    • v.36 no.3
    • /
    • pp.123-130
    • /
    • 2003
  • Background: In order to develop the acute heart failure model for the animal experiment of the pneumatic ventricular assist device, we decided to use young pig whose coronary artery distribution is almost the same as humans and also very cheap in price. The purpose of this study is to develop stable, reproducible acute ischemic heart failure model in swine using coronary artery ligation method. Material and Method: Five young pigs whose weights are the same as adult humans are under experiment. Each pig was under endotracheal intubation and connected to a mechanical ventilator. Through left lateral thoracotomy, we exposed the heart and induced ischemic heart failure by coronary artery ligation. The ligation began at the distal part of the left anterior descending coronary artery. After 5 minutes of initial ligation we reperfused the artery and then re-ligated. Before and after each ligation-reperfusion procedure we assessed the left ventricular end-diastolic pressure, arterial pressure, and cardiac index. We also measured left ventricular end-diastolic dimension, end-systolic dimension, fractional shortening, ejection fraction using intraoperative epicardial echocardiography. After appropriate heart failure was established with sequential (from distal part of LAD to proximal location) ligation-reperfusion-ligation procedure, we inserted the ventricular assist device and operated. Result: We established stable acute ischemic heart failure in 3 of 5 young pigs with this sequential ligation-reperfusion-ligation procedure, and could maintained 50% less ejection fraction before the procedure according to intraoperative epicardial echocardiography. We also observed no ventricular arrhythmia usually associated with simple coronary artery ligation in large animals and no cardiac arrest associated with ventricular arrhythmia or myocardial stunning. In pathologic specimen, we observed scattered ischemic myocardium in all around the ischemic field induced by coronary artery ligation. Conclusion: Under the concept of ischemic preconditioning, we developed safe and reproducible acute ischemic heart failure model in swine using sequential coronary artery ligation-reperfusion-ligation method.

Prediction of Improvement of Myocardial Wall Motion after Coronary Artery Bypass Surgery Using Rest T1-201/Dipyridamole Stress Gated Tc-99m-MIBI/24 Hour Delay T1-201 SPECT (휴식기 T1-201/디피리다몰 부하 게이트 Tc-99m-MIBI/24시간 지연 T1-201 SPECT를 이용한 관상동맥 우회로 수술 후 심근벽 운동 호전의 예측)

  • Lee, Dong-Soo;Lee, Won-Woo;Yeo, Jeong-Seok;Kim, Seok-Ki;Kim, Ki-Bong;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.497-508
    • /
    • 1998
  • Purpose: Using rest T1-201/dipyridamole stress gated Tc-99m-MIBI/ 24 hour delay T1-201 SPECT, we investigated the predictive values of the markers of the stress-rest reversibility (Rev), T1-201 rest perfusion (Rest), T1-201 24 hour redistribution (Del) and Tc-99m-MIBI gated systolic thickening (Thk) for wall motion improvement after coronary artery bypass surgery. Materials and Methods: In 39 patients (M;F= 34:5, age $58{\pm}8$), preoperative and postoperative (3 months) SPECT were compared. 24 hour delayed SPECT was done in 16 patients having perfusion defects at rest. Perfusion or wall motion was scored from 0 to 3 (0: normal to 3: defect or dyskinesia). Wall motion was abnormal in 142 segments among 585 segments of 99 artery territories which were surgically revascularized. Results: After bypass surgery, ejection fraction increased from $37.8{\pm}9.0%$ to $45.5{\pm}12.3%$ in 22 patients who had decreased ejection fraction preoperatively. Wall motion improved in 103 (72.5%) segments among 142 dysfunctional segments. Positive predictive values (PPV) of Rev, Rest, Del, and Thk were 83%, 76%, 43%, and 69% respectively. Negative predictive values (NPV) of Rev, Rest, Del, and Thk were 48%, 44%, 58%, and 21%, respectively. Rest/gated stress/delay SPECT had PPV of 74% and NPV of 46%. Though univariate logistic regression analysis revealed Rev (p=0.0008) and Rest (p=0.024) as significant predictors, stepwise multivariate test found Rev as the only good predictor (p=0.0008). Conclusion: Among independent predictors obtained by rest T1-201/ stress gated Tc-99m-MIBI/ delayed T1-201 myocardial SPECT for wall motion improvement after bypass surgery, stress-rest reversibility was the single most useful predictor.

  • PDF

Studies for B-type Natriuretic Peptide Values and Its Association with Diastolic Echocardiographic Parameters (B-type Natriuretic Peptide 수치와 이완기 심초음파 파라미터와의 연관성 연구)

  • Bae, Seong-Jo;Kwon, Kisang;Lee, Eun Ryeong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.4
    • /
    • pp.394-400
    • /
    • 2016
  • The b-type natriuretic peptide (BNP) values and increase on functional disorder in the ventricle, and are used as an index to diagnose heart failure and predict the prognosis. BNP values is known to be relevant to dyssystole in congestive heart failure. This study aimed to identify correlation between the BNP values and the items that indicate the diastolic function in echocardiography. The research divided 188 patients who went through the BNP test and echocardiography in the hospital into the groups with the BNP values; <100, 100-300, 301-600, 601-900, and >901 pg/mL. As the BNP values increase, there was relevance with the echocardiography items of ejection fraction, size of left atrium, E velocity, A velocity, Deceleration time, E/A ratio, E', A', S' and E/E'. In comparison on the groups divided based on the BNP values, E/E' had the highest relevance. The research also categorized 67 patients who diagnosed with heart failure. In comparison on the groups of the heart failure patients, the BNP values of the three groups of Grade I: $623.0{\pm}459.7pg/mL$, Grade II: $1013.2{\pm}1155.1pg/mL$ and Grade III: $1693.4{\pm}1544.0pg/mL$, respectively (p<0.01). As the grade was higher, there was a higher relevance with the echocardiography items of ejection fraction, size of left atrium, E velocity, A velocity, Deceleration time, E/A ratio, E', A', S' and E/E' (p<0.001). Higher BNP values had a higher relevance with the items that indicate the diastolic function in echocardiography and the BNP values of the Restrictive physiology group were the highest in echocardiography. So the BNP values was thought to be valuable to predict diastolic function of heart.

Midterm Results of the Bioprosthesis in Mitral Position (조직판막을 이용한 승모판 치환술의 중기 성적)

  • Cho, Hyun-Jin;Lee, Jae-Won;Jung, Sung-Ho;Je, Hyoung-Gon;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.695-702
    • /
    • 2008
  • Background: The choice between a bioprosthetic and a mechanical valve is an important decision in cardiac valve surgery, and the durability of the tissue valve is a major decision factor. We retrospectively evaluated the midterm results of bioprosthetic valve replacement in the mitral position. Material and Method: The subjects were all patients who had undergone mitral bioprosthesis replacement between July 1989 and August 200.7. Among the 216 patients, there were 236 surgical cases. The mean age was $63{\pm}15$ years, and the male to female ratio was 1 : 3. We retrospectively analyzed hospital and outpatient records such that the total follow-up duration amounted to 760.2 patient-years, and the mean follow-up duration was $41.9{\pm}40.7$ months (range $0{\sim}212$ months). Result: Early death occurred in 18 patients (8.3%), and 13 of these underwent concomitant cardiac procedures. The survival rate after 5 years was $79.9{\pm}3.5%$, and the survival rate after 8 years was $65.5{\pm}5.5%$, while freedom from structural valve deterioration (SVD) was $96.2{\pm}2.2%$ at 5 years and $85.9{\pm}5.3%$ at 8 years. Freedom from reoperation was $90.6{\pm}1.7%$ at 5 years and $90.4{\pm}4.2%$ at 8 years, while freedom from reoperation for SVD was $98.1{\pm}1.2%$ at 5 years and $92.3{\pm}4.1%$ at 8 years. On multivariate analysis of preoperative risk factors, small valve size (between 25mm and 27mm) was a significant risk factor for reoperation, and low LV ejection fraction (<40%) was a significant risk factor for SVD and mortality. Conclusion: Survival and freedom from reoperation for SVD in mitral bioprosthesis replacement had acceptable midterm results, but freedom from SVD Was relatively low. In particular, since SVD increased sharply at the eighth postoperative year, frequent follow-up and echocardiograms around that time will be helpful for the early detection of SVD. It will be necessary to conduct further studies involving long-term follow-up and more patients.

Left ventricular dysfunction measured by tissue Doppler imaging and strain rate imaging in hypertensive adolescents (고혈압 청소년에서 tissue Doppler imaging과 strain rate imaging을 이용한 좌심실 기능 이상에 대한 연구)

  • Ahn, Hye Mi;Jung, Sun Ok;Kwon, Jung Hyun;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.1
    • /
    • pp.72-79
    • /
    • 2010
  • Purpose: Left ventricular (LV) hypertrophy and impaired diastolic function may occur early in systemic hypertension. Diastolic dysfunction is associated with increased cardiovascular risk. Tissue Doppler imaging (TDI)-derived tissue velocity and strain rate are new parameters for assessing diastolic dysfunction. The aim of this study is to determine whether TDI and strain rate imaging (SRI) would improve the ability to recognize early impaired diastolic and systolic functions compared with conventional echocardiography in hypertensive adolescents. Methods: We included 38 hypertensive patients with systolic blood pressure above 140 mmHg or diastolic blood pressure above 90 mmHg. Ejection fraction and myocardial performance index (MPI) were estimated by conventional echocardiography. Peak systolic myocardial velocity, early diastolic myocardial velocity (Em), and peak late diastolic myocardial velocity (Am) were obtained by using TDI and SRI. Results: In the hypertensive group, interventricular septal thickness was significantly increased on M-mode echocardiography. Em/Am was significantly decreased at the mitral valve annulus. Among hypertensive subjects, the E strain rate at basal, mid, and apex was significantly decreased. Systolic strain was significantly decreased at the septum in the hypertensive group. Conclusion: Strain rate might be a useful new parameter for the quantification of both regional and global LV functions and could be used in long-term follow up in hypertensive patients. Early identification by SRI of subjects at risk for hypertensive and ventricular dysfunction may help to stratify risk and guide therapy. Further studies, including serial assessment of LV structure and function in a larger number of adolescents with hypertension, is necessary.

A Study of the Level of Cardiac Troponin I in Patients with Clinically Suspected Acute Myocarditis Treated with Intravenous Gammaglobulin (심근형 Troponin I의 증가로 급성 심근염의 진단을 받은 환아에서 정맥용 면역글로부린 치료 효과에 대한 연구)

  • Kim, Minshik;Lee, Youngok;Chun, Yoonae
    • Pediatric Infection and Vaccine
    • /
    • v.5 no.2
    • /
    • pp.267-275
    • /
    • 1998
  • Purpose : We have studied the changes of cardiac troponin I(cTnI) level and left ventricular ejection fraction(LVEF) before and after treatment of IVGG to evaluate the efficacy of single high dose of intravenous gammaglobulin(IVGG)(2.0gm/kg) therapy for improving cardiac function and clinical symptoms and signs in patients with clinically suspected acute myocarditis. Methods : The patients consisted of 18 cases who admitted increased cTnI with clinically suspected acute myocarditis caused by viral infection, Kawasaki disease and fever unknown origin(FUO) from Jan. 1995 to Jun. 1998. The control group consisted of 20 cases suffered from hand-foot-mouth disease, herpangina and high fever with rash. The level of cTnI was measured by Chemiluminiscent immunoassay method(normal<0.1ng/ml) and cardiac function was evaluated by left ventricular ejection fraction(LVEF)(normal 64~83%) by echocardiogram. Results : The level of cTnI increased to $0.306{\pm}0.209ng/ml$ and LVEF decreased to $60.1{\pm}1.6%$ before treatment of IVGG significantly as compared with control group(P<0.05). All cases were returned to normal range of LVEF($71.4{\pm}3.7%$) and decreased cTnI significantly($0.089{\pm}0.082ng/ml$) after treated with IVGG within 1 week in patients group(P<0.05). Conclusion : The single high dose of IVGG(2.0gm/kg) therapy was rapid and effective improvement of cardiac function and clinical symptoms and signs of acute myocarditis, and the measurement of serum cTnI and LVEF may help to diagnose and evaluate efficacy of IVGG on it.

  • PDF

Heart Transplantation: the Seiong General Hospital Experience (심장이식 환자의 임상적 고찰)

  • 박국양;박철현
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.606-613
    • /
    • 1996
  • Cardiac transplantation has been the treatment of patients with end-stage heart disease since it was first performed in 1967. In Korea the first case was performed in 1992 and 42 patients underwent heart trans- plantation so far. The purpose of this article is to report short-term result of cardiac transplantation at our center. Between April 1994 and September 1995, 14 patients had undergone orthotopic heart transplantations. There was 12 male and 2 female patients. Mea recipient age was 34 years(range 11 to 54 years) and mean donor age was 28.4 years(16 to 50 years). Mean graft ischemic time was 120.7minutes(80 to 280 minutes). The follow-up period after transplantation was 11 months(3 to 17 months). Recipient diagnosis included dilated cardiomyopathy in 10, ischemic cardiomyopathy in 2, valvular cardiomyopathy in 1, congenital complex heart disease in 1 patient. The preoperative status of the recipients were state I (50%) and ll (50%) by UNOS classification and class 111 (5 patients) and class IV (9) by NYHA functional class. All patients were treated with triple-drug immunosuppression (cyclosporine, azathioprine, steroid) and induction with RATG. The rejection episodes were 5 times in 3 patients during the follow-up. Causes of infection were aspergillosis (2), and hepes zoster (1), CMV pneumonitis (1). Permanent pace- maker was inserted in 1 patient. Currently 9 patients are alive with seven patients in WYHA functional class I and two in class l . The ejection fraction increased from preoperative value of 19.9 $\pm$ 3.4% to postoperative value of 69.0 $\pm$ 5.6%. The causes of death were cellular rejection (1),chronic graft failure due to size-mismatching (1),respirat- oxy insufficiency due to asthma attack (1), subarachnoid hemorrhage (1), and RIO humoral rejection (1).

  • PDF