• Title/Summary/Keyword: efficiency assessment

Search Result 1,513, Processing Time 0.025 seconds

A Study on Advancing Strategy for National Environmental Geographic Informations - Focused on the National Environmental Assessment Map, Ecological Map and Land Cover Map - (국토환경지리정보 고도화 전략 연구 - 국토환경성평가지도, 생태자연도, 토지피복지도를 중심으로 -)

  • Lee, Chong-Soo
    • Journal of Environmental Policy
    • /
    • v.6 no.2
    • /
    • pp.97-122
    • /
    • 2007
  • In 2006, the Ministry of Environment of the Republic of Korea, completed the construction on national environmental geographic informations including National Environmental Assessment Map, Ecological Map, Land Cover Map and so on. At this point of time, it is necessary to establish the advance strategy on national environmental geographic information, considering the complicated characteristics. Therefore, this study suggests the advance strategy on national environmental geographic information, reflecting results of analyzing the given condition and the trend of informatization. National environmental geographic information has spacial quality to be managed dispersedly in a department unit or an operations unit. According to this quality, requirements for users who need the policy based on national environmental geographic information and complex information are not satisfactory. And, the information system centering the process of administrative affairs should be converted to one putting decision supporting first in importance. Therefore, this study sets up "the realization of the sustainable land management system by advancing national environmental geographic information" as the vision of the advancing strategy. In order to accomplish the vision, this study established the purpose as follow; constructing strategic and geographic information based on knowledge, arranging the foundation to open information to the public transparently, building expanded and integrated national environmental geographic information, embodying the environmental administration based on national environmental geographic information, enhancing the efficiency of national environmental geographic information, and supporting efficiently the process of administrative affairs. And this study suggests executive plans to achieve the vision and the purpose as next; developing the quality control program to verify the information confidence, building the system to integrate and to provide environmental information, collecting information, readjusting laws and regimes in parts of the construction, the application and the management of the system, and operating the task process, human power, organization and information technology. This study puts the emphasis on providing the turning opportunity politically which is possible to make sure of the information confidence in quality, advancing from the expansion of one in quantity. However, this improvement strategy doesn't reflect all national environmental geographic information and current status of environmental administrations. Therefore, for applying the result of this study to the actual environmental administration, it is necessary to discuss regularly the systematic categorization of national environmental geographic information, to interview with the contracting parties and so on hereafter.

  • PDF

A Feasibility Study on the Deep Soil Mixing Barrier to Control Contaminated Groundwater (오염지하수의 확산방지를 위한 대체 혼합차수재의 적용에 관한 연구)

  • 김윤희;임동희;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.53-59
    • /
    • 2001
  • There is a lot of method to manage the insanitary landfill but vertical cutoff walls have been widespreadly used and were installed into the subsurface to act as a barrier to horizontal groundwater flow, The stabilized material such as specialized cement or mixed soil with additives has been generally applied for the materials of the deep soil mixing barrier in korea. The amount of the stabilized material is dependent on the field conditions, because the mixing ratio of the material and the field soil should achieve a requirement in the coefficient of permeability, lower than 1.0$\times$$10^{7}$cm/sec. This study determined the quantity and optimized function ratio of the stabilized material in the formation process of the mixed barrier that was added with stabilized material on the field soil classified into SW-SC under USCS (Unified Soil Classification System). After that the fly ash and lime were selected as an additives an that could improve the function of the stabilized material and then the method to improve the functional progress in the usage of putting into the stabilized material as an appropriate ratio was studied and reviewed. The author used the flexible-wall permeameter for measuring the permeability and unconfined compressive strength tester for compressive strength, and in the view of environmental engineering the absorption test of heavy metals and leaching test regulated by Korean Waste Management Act were performed. As the results, the suitable mixing ratio of the stabilized material in the deep soil mixing barrier was determined as 13 percent. To make workability easy, the ratio of stabilized material and water was proven to be 1 : 1.5. With the results, the range of the portion of the additives(fly ash : lime= 70 : 30) was proven to be 20-40% for improving the function of the stabilized material, lowering of permeability. In heavy metal absorption assessment of the mixing barrier system with the additives, the result of heavy metal absorption was proved to be almost same with the case of the original stabilized material; high removal efficiency of heavy metals. In addition, the leaching concentration of heavy metals from the leaching test for the environmental hazard assessment showed lower than the regulated criteria.

  • PDF

Characteristics of Pollution Loading from Kyongan Stream Watershed by BASINS/SWAT. (BASINS/SWAT 모델을 이용한 경안천 유역의 오염부하 배출 특성)

  • Jang, Jae-Ho;Yoon, Chun-Gyeong;Jung, Kwang-Wook;Lee, Sae-Bom
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.2
    • /
    • pp.200-211
    • /
    • 2009
  • A mathematical modeling program called Soil and Water Assessment Tool (SWAT) developed by USDA was applied to Kyongan stream watershed. It was run under BASINS (Better Assessment Science for Integrating point and Non-point Sources) program, and the model was calibrated and validated using KTMDL monitoring data of 2004${\sim}$2008. The model efficiency of flow ranged from very good to fair in comparison between simulated and observed data and it was good in the water quality parameters like flow range. The model reliability and performance were within the expectation considering complexity of the watershed and pollutant sources. The results of pollutant loads estimation as yearly (2004${\sim}$2008), pollutant loadings from 2006 were higher than rest of year caused by high precipitation and flow. Average non-point source (NPS) pollution rates were 30.4%, 45.3%, 28.1% for SS, TN and TP respectably. The NPS pollutant loading for SS, TN and TP during the monsoon rainy season (June to September) was about 61.8${\sim}$88.7% of total NPS pollutant loading, and flow volume was also in a similar range. SS concentration depended on precipitation and pollution loading patterns, but TN and TP concentration was not necessarily high during the rainy season, and showed a decreasing trend with increasing water flow. SWAT based on BASINS was applied to the Kyongan stream watershed successfully without difficulty, and it was found that the model could be used conveniently to assess watershed characteristics and to estimate pollutant loading including point and non-point sources in watershed scale.

Performance assessment of an urban stormwater infiltration trench considering facility maintenance (침투도랑 유지관리를 통한 도시 강우유출수 처리 성능 평가)

  • Reyes, N.J. D.G.;Geronimo, F.K.F.;Choi, H.S.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.424-431
    • /
    • 2018
  • Stormwater runoff containing considerable amounts of pollutants such as particulates, organics, nutrients, and heavy metals contaminate natural bodies of water. At present, best management practices (BMP) intended to reduce the volume and treat pollutants from stormwater runoff were devised to serve as cost-effective measures of stormwater management. However, improper design and lack of proper maintenance can lead to degradation of the facility, making it unable to perform its intended function. This study evaluated an infiltration trench (IT) that went through a series of maintenance operations. 41 monitored rainfall events from 2009 to 2016 were used to evaluate the pollutant removal capabilities of the IT. Assessment of the water quality and hydrological data revealed that the inflow volume was the most relative factor affecting the unit pollutant loads (UPL) entering the facility. Seasonal variations also affected the pollutant removal capabilities of the IT. During the summer season, the increased rainfall depths and runoff volumes diminished the pollutant removal efficiency (RE) of the facility due to increased volumes that washed off larger pollutant loads and caused the IT to overflow. Moreover, the system also exhibited reduced pollutant RE for the winter season due to frozen media layers and chemical-related mechanisms impacted by the low winter temperature. Maintenance operations also posed considerable effects of the performance of the IT. During the first two years of operation, the IT exhibited a decrease in pollutant RE due to aging and lack of proper maintenance. However, some events also showed reduced pollutant RE succeeding the maintenance as a result of disturbed sediments that were not removed from the geotextile. Ultimately, the presented effects of maintenance operations in relation to the pollutant RE of the system may lead to the optimization of maintenance schedules and procedures for BMP of same structure.

Evaluation of stream flow and water quality behavior by weir operation in Nakdong river basin using SWAT (SWAT을 이용한 낙동강유역의 보 개방에 따른 하천유량 및 수질 거동 분석)

  • Lee, Ji Wan;Jung, Chung Gil;Woo, So Young;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.5
    • /
    • pp.349-360
    • /
    • 2019
  • The purpose of this study is to evaluate the stream flow and water quality (SS, T-N, and T-P) behavior of Nakdong river basin ($23,609.3km^2$) by simulating the dam and weir operation scenarios using SWAT (Soil and Water Assessment Tool). The operation senarios are the simultaneous release for all dam and weirs (scenario 1), simultaneous release for all weirs (scenario 2), and sequential release for the weirs with one month interval from upstream weirs (scenario 3). Before evaluation, the SWAT was calibrated and validated using 11 years (2005-2015) daily multi-purpose dam inflow at 5 locations (ADD, IHD, HCD, MKD, and MYD), multi-function weir inflow at 7 locations (SHW, GMW, CGW, GJW, DSW, HCW, and HAW), and monthly water quality monitoring data at 6 locations (AD-4, SJ-2, EG, HC, MK-4, and MG). For the two dam inflow and dam storage, the Nash-Sutcliffe efficiency (NSE) was 0.56~0.79, and the coefficient of determination ($R^2$) was 0.68~0.90. For water quality, the $R^2$ of SS, T-N, and T-P was 0.64~0.79, 0.51~0.74, and 0.53~0.72 respectively. For the three scenarios of dam and weir release combination suggested by the ministry of environment, the scenario 1 and 3 operations were improved the stream water quality (for T-N and T-P) within the 3 months since the time of release, but it showed the negative effect for 3 months after compared to scenario 2.

Evaluation of stream flow and water quality changes of Yeongsan river basin by inter-basin water transfer using SWAT (SWAT을 이용한 유역간 물이동량에 따른 영산강유역의 하천 유량 및 수질 변동 분석)

  • Kim, Yong Won;Lee, Ji Wan;Woo, So Young;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1081-1095
    • /
    • 2020
  • This study is to evaluate stream flow and water quality changes of Yeongsan river basin (3,371.4 km2) by inter-basin water transfer (IBWT) from Juam dam of Seomjin river basin using SWAT (Soil and Water Assessment Tool). The SWAT was established using inlet function for IBWT between donor and receiving basins. The SWAT was calibrated and validated with 14 years (2005 ~ 2018) data of 1 stream (MR) and 2 multi-functional weir (SCW, JSW) water level gauging stations, and 3 water quality stations (GJ2, NJ, and HP) including data of IBWT and effluent from wastewater treatment plants of Yeongsan river basin. For streamflow and weir inflows (MR, SCW, and JSW), the coefficient of determination (R2), Nash-Sutcliffe efficiency (NSE), root mean square error (RMSE), and percent bias (PBIAS) were 0.69 ~ 0.81, 0.61 ~ 0.70, 1.34 ~ 2.60 mm/day, and -8.3% ~ +7.6% respectively. In case of water quality, the R2 of SS, T-N, and T-P were 0.69 ~ 0.81, 0.61 ~ 0.70, and 0.54 ~ 0.63 respectively. The Yeongsan river basin average streamflow was 12.0 m3/sec and the average SS, T-N, and T-P were 110.5 mg/L, 4.4 mg/L, 0.18 mg/L respectively. Under the 130% scenario of IBWT amount, the streamflow, SS increased to 12.94 m3/sec (+7.8%), 111.26 mg/L (+0.7%) and the T-N, T-P decreased to 4.17 mg/L (-5.2%), 0.165 mg/L (-8.3%) respectively. Under the 70% scenario of IBWT amount, the streamflow, SS decreased to 11.07 m3/sec (-7.8%), 109.74 mg/L (-0.7%) and the T-N, T-P increased to 4.68 mg/L (+6.4%), 0.199 mg/L (+10.6%) respectively.

Comparison of Natural Flow Estimates for the Han River Basin Using TANK and SWAT Models (TANK 모형과 SWAT 모형을 이용한 한강유역의 자연유출량 산정 비교)

  • Kim, Chul-Gyum;Kim, Nam-Won
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.3
    • /
    • pp.301-316
    • /
    • 2012
  • Two models, TANK and SWAT (Soil and Water Assessment Tool) were compared for simulating natural flows in the Paldang Dam upstream areas of the Han River basin in order to understand the limitations of TANK and to review the applicability and capability of SWAT. For comparison, simulation results from the previous research work were used. In the results for the calibrated watersheds (Chungju Dam and Soyanggang Dam), two models provided promising results for forecasting of daily flows with the Nash-Sutcliffe model efficiency of around 0.8. TANK simulated observations during some peak flood seasons better than SWAT, while it showed poor results during dry seasons, especially its simulations did not fall down under a certain value. It can be explained that TANK was calibrated for relatively larger flows than smaller ones. SWAT results showed a relatively good agreement with observed flows except some flood flows, and simulated inflows at the Paldang Dam considering discharges from upper dams coincided with observations with the model efficiency of around 0.9. This accounts for SWAT applicability with higher accuracy in predicting natural flows without dam operation or artificial water uses, and in assessing flow variations before and after dam development. Also, two model results were compared for other watersheds such as Pyeongchang-A, Dalcheon-B, Seomgang-B, Inbuk-A, Hangang-D, and Hongcheon-A to which calibrated TANK parameters were applied. The results were similar to the case of calibrated watersheds, that TANK simulated poor smaller flows except some flood flows and had same problem of keeping on over a certain value in dry seasons. This indicates that TANK application may have fatal uncertainties in estimating low flows used as an important index in water resources planning and management. Therefore, in order to reflect actually complex and complicated physical characteristics of Korean watersheds, and to manage efficiently water resources according to the land use and water use changes with urbanization or climate change in the future, it is necessary to utilize a physically based watershed model like SWAT rather than an existing conceptual lumped model like TANK.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Efficiency and continuancy of basic CPR (Cardiopulmonary Resuscitation) education for the higher grade students of elementary schools (초등학교 고학년생의 기본심폐소생술 교육효과 및 지속성)

  • Kim, Hee-Jung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.3
    • /
    • pp.87-98
    • /
    • 2008
  • Purpose : This study was designed to figure out the necessity of continuing basic CPR education for the higher grade students of elementary school. The assessment contents were knowledge, practice ability, precision level of CPR skills and continuation of the educational efficiency. Methods : Twenty two students of 4th and 5th grade of elementary school in K city in Chungcheongnam-do were recruited for this study. The study method was a control group of non-synchronized design. A preliminary study was done on October 27 in 2006. The main study was performed from February 14 to May 11 in 2007. The researcher adopted the method of Kyung-hui, Kang (1998) such as awareness, attitude and knowledge in control group, emergency medical technician test protocol, Anne/SkillReporter$^{(R)}$ in case of the basic CPR knowledge. Four times of measures were done in shortly after practicing CPR, 4 weeks after the education, 8 weeks after the education, and 12 weeks after the education. By using SPSS/PC+ (version 12.0), the researcher analyzed the collected data based on frequency, percentage, repeated measurement, ANOVA (analysis of variance), and sidak (multiple comparison - sidak). Results : 1) The confidence of people in the control group in terms of practicing CPR showed a statistically meaningful difference (t = 10.230, p = .000) before/after CPR education. Therefore, hypothesis No.1-1 was accepted. 2) The educational necessity of people in the control group showed no statistically meaningful difference (t = -1.695, p = 0.105) before/after CPR education. Therefore, hypothesis No.1-2 was rejected. 3) The knowledge points of people in the control group showed a statistically meaningful difference (t = -7.731, p = .000) before/after CPR education. Therefore, hypothesis No.2 was accepted. 4) The confidence of people in the control group in terms of practicing CRP showed no meaningful difference (F = 2.789, p = 0.072) as time passed. Therefore, hypothesis No.3 was rejected. 5) The knowledge of people in the control group showed a meaningful difference (F = 9.090, p = .000) as time passed. Therefore, hypothesis No.4 was accepted. 6) The capability of people in the control group in terms of practicing CPR showed a statistically meaningful difference (F = 42.795, p = .000) as time passed. Therefore, hypothesis No.5 was accepted. 7) The precision level of CPR skill of people in the control group showed a statistically meaningful difference (F = 25.198, p = .000) as time passed. Therefore, hypothesis No.6-1 was accepted. 8) The precision level of chest compression skill of people in the control group showed a statistically meaningful difference (F = 5.188, p = .003). Therefore, hypothesis No.6-2 was accepted. Conclusion : In a nutshell, CPR education for the 4th and 5th graders of elementary schools had an influence on their confidence in practicing CPR and on their knowledge. This study showed that as time passed. the educational effect declined in terms of knowledge point, capability of practicing CPR, and the precision level of CRP skill. The results of the study could be postulated into the fact that re-education within 8 weeks after the first education was essential to retaining the educational effect. Therefore, we need to vitalize the CPR education for elementary school students repeatedly on a regular basis in order to continue the educational effect after they were grown-ups and to make them play their roles as a first aider.

  • PDF

Comparative assessment and uncertainty analysis of ensemble-based hydrologic data assimilation using airGRdatassim (airGRdatassim을 이용한 앙상블 기반 수문자료동화 기법의 비교 및 불확실성 평가)

  • Lee, Garim;Lee, Songhee;Kim, Bomi;Woo, Dong Kook;Noh, Seong Jin
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.10
    • /
    • pp.761-774
    • /
    • 2022
  • Accurate hydrologic prediction is essential to analyze the effects of drought, flood, and climate change on flow rates, water quality, and ecosystems. Disentangling the uncertainty of the hydrological model is one of the important issues in hydrology and water resources research. Hydrologic data assimilation (DA), a technique that updates the status or parameters of a hydrological model to produce the most likely estimates of the initial conditions of the model, is one of the ways to minimize uncertainty in hydrological simulations and improve predictive accuracy. In this study, the two ensemble-based sequential DA techniques, ensemble Kalman filter, and particle filter are comparatively analyzed for the daily discharge simulation at the Yongdam catchment using airGRdatassim. The results showed that the values of Kling-Gupta efficiency (KGE) were improved from 0.799 in the open loop simulation to 0.826 in the ensemble Kalman filter and to 0.933 in the particle filter. In addition, we analyzed the effects of hyper-parameters related to the data assimilation methods such as precipitation and potential evaporation forcing error parameters and selection of perturbed and updated states. For the case of forcing error conditions, the particle filter was superior to the ensemble in terms of the KGE index. The size of the optimal forcing noise was relatively smaller in the particle filter compared to the ensemble Kalman filter. In addition, with more state variables included in the updating step, performance of data assimilation improved, implicating that adequate selection of updating states can be considered as a hyper-parameter. The simulation experiments in this study implied that DA hyper-parameters needed to be carefully optimized to exploit the potential of DA methods.