• Title/Summary/Keyword: effective wavelength

Search Result 436, Processing Time 0.031 seconds

Improvement of System Performance Through Concentrated RDPS in WDM Transmission Links with Dispersion Management (분산 제어가 적용된 WDM 전송 링크에서 집중 RDPS를 통한 시스템 성능 개선)

  • Lee, Seong-Real
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.971-980
    • /
    • 2013
  • System performance improvement through the concentrated residual dispersion per span (RDPS) in special transmission fiber spans in optical transmission links with dispersion management (DM) for wavelength division multiplexed (WDM) transmission is investigated through the comparison with the performance in optical transmission links with uniform RDPS in every fiber spans. It is confirmed that, in optical links with RDPS of 0 ps/nm uniformly distributed in the rest fiber spans, if RDPS of 300 ps/nm and 1,320 ps/nm are concentrated in 5th-13th fiber spans and 6th-13th fiber spans, respectively, then the best performance is obtained. It is also confirmed that optimal net residual dispersion (NRD) controlled by precompensation and postcompensation are 10 ps/nm and -10 ps/nm, respectively, in all two cases, and the effective launching power range below 1 dB eye opening penalty (EOP) in the concentrated RDPS of 300 ps/nm and 1,320 ps/nm are improved by 2 dB and 6 dB than optical transmission links with the uniformly distributed RDPS, respectively.

Effective of Body Temperature Increasing during Brain MRI scan (MRI 검사 시 체온상승 효과: 1.5 T vs 3.0 T)

  • Kim, Myeong Seong;Lee, Jongwoong;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 2017
  • As the Radiofrequency(RF) increases with the magnetic field strength, the wavelength of the RF excitation field becomes smaller, which leads to more the thermal effect in the human-body placed in the electric field. MRI scanner used was GE signa 1.5T, HDx 3.0T and Philips 3.0T with same routine clinical sequence protocol. Therefore temperature was measured before and after each scan. Taken the temperatures in the ear with ear infra-red type thermometer(Braun co). 3.0T were temperature increases more than $0.15^{\circ}C$ and GE 3.0T MRI equipment about $0.14^{\circ}C$ higher than the Philips 3.0T MRI(p<0.012). Psychogenic status was investigated by the survey respondents about their status can not just answer therefore, a little different from the expected. In our study of Thermal effect of clinical MRI with clinical protocol sequence, we found that the 3.0T in the body-temperature rise was greater than the 1.5T. Therefore, in clinical 3.0T examine the dangerous situation caused by the temperature rise occurred (burns, impaired thermoregulatory mechanism in patients with high-temperature damage, exhaustion occurs due to excessive sweating), not to appear the more watched the patient's condition with procedure.

Enhancement of Ionospheric Correction Method Based on Multiple Aperture Interferometry (멀티간섭기법에 기반한 이온왜곡 보정기법의 보완)

  • Lee, Won-Jin;Jung, Hyung-Sup;Chae, Sung-Ho;Baek, Wonkyung
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.2
    • /
    • pp.101-110
    • /
    • 2015
  • Synthetic Aperture Radar Interferometry (InSAR) is affected by various noise source such as atmospheric artifact, orbital error, processing noise etc.. Especially, one of the dominant noise source for long-wave SAR system, such as ALOS PALSAR (L-band SAR satellite) is the ionosphere effect because phase delays on radar pulse through the ionosphere are proportional to the radar wavelength. To avoid misinterpret of phase signal in the interferogram, it is necessary to detect and correct ionospheric errors. Recently, a MAI (Multipler Aperture SAR Interferometry) based ionospheric correction method has been proposed and considered one of the effective method to reduce phase errors by ionospheric effect. In this paper, we introduce the MAI-based method for ionospheric correction. Moreover we propose an efficient method that apply the method over non-coherent area using directional filter. Finally, we apply the proposed method to the ALOS PALSAR pairs, which include the west sea coast region in Korea. A polynomial fitting method, which is frequently adopted in InSAR processing, has been applied for the mitigation of phase distortion by the orbital error. However, the interferogram still has low frequency of Sin pattern along the azimuth direction. In contrast, after we applied the proposed method for ionospheric correction, the low frequency pattern is mitigated and the profile results has stable phase variation values within ${\pm}1rad$. Our results show that this method provides a promising way to correct orbital and ionospheric artifact and would be important technique to improve the accuracy and the availability for L-band or P-band systems.

The Study on the Application of He-Ne Laser with Low Energy ILIB to the Superficial Venules (저용량(低容量) He-Ne 레이저침의 혈락적용(血絡適用) 연구(硏究))

  • Kim Sung-Chul;Cho Eun-Hee;Na Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.20 no.3
    • /
    • pp.35-47
    • /
    • 2003
  • Objective : The purpose of this study was to investigate the significance of the Oriental medical treatment using He-Ne laser with low energy intravascular Laser Irradiation of Blood(ILIB) through the superficial venules. Methods : The investigation of details connected with the superficial venules in the literature is performed. The investigation of details connected with the pricking blood techniques through the superficial venules in the literature is performed. The classification of the pricking blood techniques through the superficial venules by the blood-letting puncture methods in the literature is performed. The arrangement of domestic clinical treatises on the effectiveness of medical treatment using He-Ne laser with low energy ILIB through the superficial venules is performed. The consideration on the methodology for the improvement of the clinical effectiveness of He-Ne laser with low energy ILIB through superficial venules is performed. Results and Conclusions : The superficial venules are small arteries, veins and capillaries in the superficial region of the human body. In the pricking blood techniques, there are the blood-letting puncture using the implement of acupuncture to the Jing points, Extra points and superficial blood vessels and the acupuncture using the Hirudo. The methods of the blood-letting puncture are classified into the venous blood-letting puncture, the pricking , the picking out white fiber-like substances from the subcutaneous tissue, the cluster needling, the scattered needling, the blood-letting puncture of the tready collateral branch of the large channel and the blood-letting puncture of skin. The He-Ne laser with low energy ILIB through the superficial venules belongs to the Oriental medical treatment as the method of the blood-letting puncture in the vein of cubital fossa. The He-Ne laser with low energy ILIB has an effect on hyperfibrinogenemia, hyperlipidemia, speech and motor dysfunction in the case of cerebral infarction, headache, dizziness, pain and numbness. It is considered that fundamental research on the biological change of the human body, the experimental animal and the unicellular animal, and research on the effectiveness and the safety, and the development of He-Ne laser with low energy ILIB of an effective wavelength range are necessary.

  • PDF

Determination of the complex refractive index of $Ge_2Sb_2Te_5$ using spectroscopic ellipsometry (분광타원해석법을 이용한 $Ge_2Sb_2Te_5$ 의 복소굴절율 결정)

  • Kim, S. J.;Kim, S. Y.;Seo, H.;Park, J. W.;Chung, T. H.
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.6
    • /
    • pp.445-449
    • /
    • 1997
  • The complex refractive indices of $Ge_2Se_2Te_5$ which show reversible phase change between the crystalline phase and an amorphous one depending upon the annealing process have been determined in the spectral range of 0.7-4.5 eV. The $Ge_2Se_2Te_5$ films were DC sputter deposited on the crystalline silicon substrate. The spectro-ellipsometry data of a thick film were analyzed following the modelling procedure where the quantum mechanical dispersion relation were used for the complex refractive indices of both the cryastalline phase $Ge_2Se_2Te_5$ and and amorphous phase $Ge_2Se_2Te_5$, respectively. On the other hand, with the surface micro-roughness layer whose effective thickness was determined from AFM analysis, the spectro-ellipsometry data were numerically inverted to yield the complex refractive index of $Ge_2Se_2Te_5$ at each wavelength. With these set of complex refractive indices, the reflectance spectra were calculated and those spectra obtained from the numerical inversion showed better agreement with the experimental reflection spectra for both the cryastalline phase and an amorphous phase. Finally, the thin $Ge_2Se_2Te_5$ film which has the optimum thickness of 26 nm as the medium for optical recording was also analyzed and the quantitative result of the film thickness and the surface microroughness has been reported.

  • PDF

TREATMENT OF DENTAL CARIES BY ER:YAG LASER IN CHILDREN (소아 환자에서 Er:YAG Laser를 이용한 우식 병소의 처치)

  • Jang, Eun-Young;Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.4
    • /
    • pp.558-563
    • /
    • 2000
  • The lasers have been used in dentistry for more than 30 years and the application of lasers for drilling dental hard tissue has been investigated since the early developement of lasers. Recently, the Er:YAG laser was invented for hard tissue ablation. The Er:YAG laser, having a wavelength of 2.94um, is highly absorbed in both water and hydroxiapatite, leading to a very effective material for hard tissue removal by bursting off the solid tissue component that is, enamel and dentin are removed by the Er :YAG laser by water vaporization and microexplosion, without any melting of inorganic tissues. Therefore, the Er:YAG laser produced round craters with well defined margins and the surrounding tissues had no cracks and no charring. When used for cavity preparation, pulpal damage should not occur if hear buildup is minimized by careful selection of exposure parameters and by use of a water spray. The present study demonstrated that the Er:YAG laser cut the tooth substance adequately for composite resin restoration, without having undesirable side effects such as harmful effects on the pulp, discoloration or cracking etc. Also, the child patients were well cooperative during laser treatment mainly because of little noise, lesser vibration and minimal pain compared to conventional means of cavity preparation.

  • PDF

Development of the Most Optimized Ionizer for Reduction in the Atmospheric Pressure and Inert Gas Area (감압대기 및 불활성가스 분위기에서 적합한 정전기 제거장치의 개발)

  • Lee, Dong Hoon;Jeong, Phil Hoon;Lee, Su Hwan;Kim, Sanghyo
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.42-46
    • /
    • 2016
  • In LCD Display or semiconductor manufacturing processes, the anti-static technology of glass substrates and wafers becomes one of the most difficult issues which influence the yield of the semiconductor manufacturing. In order to overcome the problems of wafer surface contamination various issues such as ionization in decompressed vacuum and inactive gas(i.e. $N_2$ gas, Ar gas, etc.) environment should be considered. Soft X ray radiation is adequate in air and $O_2$ gas at atmospheric pressure while UV radiation is effective in $N_2$ gas Ar gas and at reduced pressure. At this point of view, the "vacuum ultraviolet ray ionization" is one of the most suitable methods for static elimination. The vacuum ultraviolet can be categorized according to a short wavelength whose value is from 100nm to 200nm. this is also called as an Extreme Ultraviolet. Most of these vacuum ultraviolet is absorbed in various substances including the air in the atmosphere. It is absorbed substances become to transit or expose the electrons, then the ionization is initially activated. In this study, static eliminator based on the vacuum ultraviolet ray under the above mentioned environment was tested and the results show how the ionization performance based on vacuum ultraviolet ray can be optimized. These vacuum ultraviolet ray performs better in extreme atmosphere than an ordinary atmospheric environment. Neutralization capability, therefore, shows its maximum value at $10^{-1}{\sim}10^{-3}$ Torr pressure level, and than starts degrading as pressure is gradually reduced. Neutralization capability at this peak point is higher than that at reduced pressure about $10^4$ times on the atmospheric pressure and by about $10^3$ times on the inactive gas. The introductions of these technology make it possible to perfectly overcome problems caused by static electricity and to manufacture ULSI devices and LCD with high reliability.

Studies on Curved Diffractive Optical Elements in EUV (극자외선 영역에서 곡면 DOEs에 관한 연구)

  • Choi, Sung-Eul;Lee, Yong-Woo;Kwon, Myung-Hoi;Kim, Yong-Hoo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.304-312
    • /
    • 2005
  • Field performance of several different types of diffractive optical elements(DOEs) has been carried out. Using Zemax model, we have designed five different types of DOEs, such as transmissive flat-DOE, transmissive curved-DOE, reflective flat-DOE, reflective curved-DOE and parabolic mirror, We have applied two different wavelengths, i.e., 13 m(EUV) and 632.8 nm(visible) to above DOEs. Off_axis dominate aberrations and the diffraction limiting (Rayleigh limit) field angles have been investigated and compared at both wavelengths for each DOE. At diffraction limit, field angle of curved-DOEs was much greater than that of flat-DOEs for both transmission and reflective types. We also showed that dominated off_axis aberration of flat-DOEs was coma, but that of curved-DOEs was mixture of astigmatism and curvature of field. The measured field angle and expected OPD aberrations were well coincided with theoretical ones. Increasing the ratio of field angle with wavelength was more effective in curved-DOEs than flat-DOEs.

CuO Nanograss as a Substrate for Surface Enhanced Raman Spectroscopy

  • Lee, Jun-Young;Park, Jiyun;Kim, Jeong-Hyun;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.249-249
    • /
    • 2013
  • Surface-enhanced Raman spectroscopy (SERS) is a sensitive approach to detect and to identify a variety of molecules. To enhance the Raman signal, optimization of the gap between nanostructures is quite important. One-dimensional materials such as nanowires, nanotubes, and nanograsses have great potential to be used in SERS due to their unique sizes and shape dependent characteristics. In this study we investigate a simple way to fabricate SERS substrates based on randomly grown copper oxide (CuO) nanowires. CuO nanograss is fabricated on pre-cleaned Cu foils. Cu oxidized in an ammonium ambient solution of 2.5 M NaOH and 0.1 M $(NH_4)_2S_2O_8$ at $4^{\circ}C$ for 10, 30, and 60 minutes. Then, Cu(OH)2 nanostructures are formed and dried at $180^{\circ}C$ for 2 h. With the drying process, the Cu(OH)2 nanostructure is transformed to CuO nanograss by dehydration reaction. CuO nanograss are grown randomly on Cu foil with the average length of 10 ${\mu}m$ and the average diameter of a 100 nm. CuO nanograsses are covered by Ag with various thicknesses from 10 to 30 nm using a thermal evaporator. Then, we immerse uncoated and Ag coated CuO nanowire samples of various oxidation times in a 0.001M methanol-based 4-mercaptopyridine (4-Mpy) in order to evaluate SERS enhancement. Raman shift and SERS enhancement are measured using a Raman spectrometer (Horiba, LabRAM ARAMIS Spectrometer) with the laser wavelength of 532 nm. Raman scattering is believed to be enhanced by the interaction between CuO nanograss and Ag island film. The gaps between Ag covered CuO nanograsses are diverse from <10 nm at the bottom to ~200 nm at the top of nanograsses. SERS signal are improved where the gaps are minimized to near 10s of nanometers. There are many spots that provide sufficiently narrow gap between the structures on randomly grown CuO nanograss surface. Then we may find optimal enhancement of Raman signal using the mapping data of average results. Fabrication of CuO nanograss based on a solution method is relatively simple and fast so this result can potentially provide a path toward cost effective fabrication of SERS substrate for sensing applications.

  • PDF

NRZ versus RZ Modulation Format in Lumped Dispersion Managed Systems (집중형 분산 제어 시스템에서 NRZ 변조 형식 대 RZ 변조 형식)

  • Lee, Seong-Real;Cho, Sung-Eon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.2
    • /
    • pp.328-335
    • /
    • 2008
  • The system performance of NRZ format in WDM transmission system with lumped dispersion management(DM) and optical phase conjugator(OPC) is compared with that of RZ format. It is confirmed that eye opening penalty(EOP) of both NRZ and RZ format in WDM transmission system having lumped DM combined with OPC are greatly improved than those in WDM system with only OPC. The optimal net residual dispersion(NRD) in the case of RZ format is decided to so small value that path-averaged dispersion coefficient become almost zero, while that in the case of NRZ format is decided to larger value, for the best improvement of overall WDM channels. It is also confirmed that EOP in the case of RZ format is more improved than that in the case of NRZ format in lumped DM with optimal NRD. This is resulted from that lumped DM combined with OPC suppress the signal distortion due to intrachannel four-wave mixing(IFWM) and intrachannel cross phase modulation(IXPM). Consequently, lumped DM combined with OPC proposed in this paper is effective technique to mitigate intrachannel nonlinearities in WDM transmitting RZ format.