• 제목/요약/키워드: effective static pressure

검색결과 115건 처리시간 0.024초

Consolidation Analysis of Vertical Drain Considering Artesian Pressure (피압수압을 고려한 연직배수공법의 압밀해석)

  • 김상규;김호일;홍병만;김현태
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 1999년도 연약지반처리위원회 학술세미나
    • /
    • pp.62-70
    • /
    • 1999
  • Artesian pressure exists in Yangsan site, the maximum value of which has been measured as high as 5 t/m$^2$. This paper deals with the prediction of consolidation settlement for the site with artesian pressure. The consolidation settlement at the site has been accelerated using vertical band drains. Since the artesian pressure gives lower effective stress than a static condition, its effect should be considered in the settlement prediction. This case study shows that the prediction of settlement and pore pressure dissipation agrees well with the measurements, when considering the artesian effect.

  • PDF

Comparison of Effects on Static Balance in Stroke Patients According to Visual Biofeedback Methods

  • Kyu-Seong Choi;Il-Ho Kwon;Won-Seob Shin
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권3호
    • /
    • pp.320-326
    • /
    • 2023
  • Objective: The purpose of this study is to investigate the impact of visual biofeedback methods utilizing pressure sensors on the static balance of stroke patients. Design: Randomized crossover study. Methods: A total of 27 patients with hemiparesis participated in this study. The following three feedback conditions were considered: condition 1 (Knowledge of performance feedback), condition 2 (Knowledge of result feedback), and condition 3 (None feedback). A force plate was used to measure static balance. The total sway length, average sway velocity, x-axis excursion, and y-axis excursion of the center of pressure were measured. One-way repeated-measures analysis of variance was employed for comparisons of variables between each condition. The statistical significance level was set at α = 0.05 for all analyses. Results: There was a significant difference in the static balance results between each feedback condition (p<0.05). In the post-hoc results, it was confirmed that the static balance was significant in the order of knowledge of performance feedback, knowledge of result feedback, and none feedback. Conclusions: When comparing the three conditions, it was observed that knowledge of performance feedback showed the most improved effect on static balance ability. As further research progresses, that this approach could be used as an effective intervention method in clinical settings.

Study of Human Tactile Sensing Characteristics Using Tactile Display System (질감 제시 장치를 이용한 촉감인지 특성 연구)

  • Son Seung-Woo;Kyung Ki-Uk;Yang Gi-Hun;Kwon Dong-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제11권5호
    • /
    • pp.451-456
    • /
    • 2005
  • This paper describes three kinds of experiments and analysis of their results related to human tactile sensitivity using an integrated tactile display system. The device can provide vibration, normal pressure and lateral slip/stretch which are important physical quantities to sense texture. We have tried to find out the efficient method of stimulating, limitation of surface discrimination by kinesthetic farce feedback and the effectiveness of the combination of kinesthetic force and tactile feedback. Seven kinds of different stimulating methods were carried out and they are single or combination of the kinesthetic force, normal static pressure, vibration, active/passive shear and moving wave. Both prototype specimen and stimulus using tactile display were provided to all examinees and they were allowed to answer the most similar sample. The experimental results show that static pressure is proper stimulus for the display of micro shape of the surface and vibrating stimulus is more effective for the display of fine surface. And the sensitivities of active touch and passive touch are compared. Since kinesthetic force feedback is appropriate to display shape and stiffness of an object, but roughness display has a limitation of resolution, the concurrent providing methods of kinesthetic and tactile feedback are applied to simulate physical properties during touching an object.

Analysis of the thermoelastic begavior on the contact joint of compound cylinder (원통결합부의 열특성 해석 (제1보) -주축베어링 내륜계의 수치해석을 중심으로-)

  • 김선민;박기환;이선규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.629-634
    • /
    • 1996
  • Heat generation in machine operating condition makes thermal deformation and thermalstress in the structure, which results in the change the contact characteristics of machine joint such s change of shrinkage fit, contact heat conductance and contact pressure. As the change of contact pressure is related to variation of static, dynamic and thermalcharacteristics, the prediction of transient contact perssure is strongly required. This paper presents some analytical results which will be effective to predict static and dynamic characteristics of the compound cylindrical structure.

  • PDF

A Study on the Closing Force according to the Opening Angle of the Door in the Smoke Control System (제연구역 출입문 개방 각도에 따른 폐쇄력에 관한 연구)

  • Oh, Won-Sin;Joung, Suck-Hwan
    • Journal of the Korea Safety Management & Science
    • /
    • 제23권4호
    • /
    • pp.43-48
    • /
    • 2021
  • In this study, the experiment was conducted on a fire door(W × H = 0.98 m × 2.19 m) installed on the vestibule. The effective leakage area for each opening angles and closing forces derived from the impulse-momentum equation was compared and analyzed with the experimental results. As a result of the experiment, the major factors affecting the door closing forces were the pressure difference and the area of the door. The difference of door closing forces between measured and calculated values by the impulse-momentum equation showed a deviation of less than ±15% at the opening angles of 5°to 10°. At the door opening angle of 2.5°, the dynamic pressure was much higher than the measured static pressure, and this pressure difference is estimated to be air resistance acting to prevent the door from being completely closed.

Development of the Most Optimized Ionizer for Reduction in the Atmospheric Pressure and Inert Gas Area (감압대기 및 불활성가스 분위기에서 적합한 정전기 제거장치의 개발)

  • Lee, Dong Hoon;Jeong, Phil Hoon;Lee, Su Hwan;Kim, Sanghyo
    • Journal of the Korean Society of Safety
    • /
    • 제31권3호
    • /
    • pp.42-46
    • /
    • 2016
  • In LCD Display or semiconductor manufacturing processes, the anti-static technology of glass substrates and wafers becomes one of the most difficult issues which influence the yield of the semiconductor manufacturing. In order to overcome the problems of wafer surface contamination various issues such as ionization in decompressed vacuum and inactive gas(i.e. $N_2$ gas, Ar gas, etc.) environment should be considered. Soft X ray radiation is adequate in air and $O_2$ gas at atmospheric pressure while UV radiation is effective in $N_2$ gas Ar gas and at reduced pressure. At this point of view, the "vacuum ultraviolet ray ionization" is one of the most suitable methods for static elimination. The vacuum ultraviolet can be categorized according to a short wavelength whose value is from 100nm to 200nm. this is also called as an Extreme Ultraviolet. Most of these vacuum ultraviolet is absorbed in various substances including the air in the atmosphere. It is absorbed substances become to transit or expose the electrons, then the ionization is initially activated. In this study, static eliminator based on the vacuum ultraviolet ray under the above mentioned environment was tested and the results show how the ionization performance based on vacuum ultraviolet ray can be optimized. These vacuum ultraviolet ray performs better in extreme atmosphere than an ordinary atmospheric environment. Neutralization capability, therefore, shows its maximum value at $10^{-1}{\sim}10^{-3}$ Torr pressure level, and than starts degrading as pressure is gradually reduced. Neutralization capability at this peak point is higher than that at reduced pressure about $10^4$ times on the atmospheric pressure and by about $10^3$ times on the inactive gas. The introductions of these technology make it possible to perfectly overcome problems caused by static electricity and to manufacture ULSI devices and LCD with high reliability.

Static Analysis of Trapezoidal Corrugated Plates under Uniformly Distributed Load (균일 분포하중을 받는 사다리꼴 주름판의 정적 해석)

  • Kim, Young-Wann
    • Journal of Power System Engineering
    • /
    • 제18권1호
    • /
    • pp.99-105
    • /
    • 2014
  • In this paper, the static characteristics of the trapezoidal corrugated plate under uniformly distributed pressure are investigated by the analytical method. Because the corrugated plate is very flexible in the corrugation direction and stiff in the transverse direction, the corrugated plate is treated as the orthotropic plate. This equivalent orthotropic plate must include both the extensional and flexural effect to obtain the precise solution. The effective extensional and flexural stiffness of the trapezoidal corrugated plate are derived to consider these effects in the analysis. To demonstrate the validity of the proposed approach, the comparison is made with the previously published results. Some numerical results are presented to check the effect of the geometric properties.

Comparison of Joint Mobilization with Manual Stretching Exercises in the Treatment of Hallux Valgus

  • Hong, Woong Pyo;Ryu, Byeong Ho;Lee, Sang Bin
    • Journal of International Academy of Physical Therapy Research
    • /
    • 제9권4호
    • /
    • pp.1614-1618
    • /
    • 2018
  • The purpose of this study was to evaluate the effect of joint mobilization and manual stretching exercises in patients with hallux valgus. Twenty-three participants were divided into two groups; joint mobilization (n=11) and manual stretching exercises (n=12). The subjects participated in the experiment for 15minutes, three times a week, four weeks. The joint mobilization (Grade III, Maitland) was performed to experimental group for a minute and then rested for 10 seconds for each set. The manual stretching was performed to control group with three exercise session (preparatory and finishing exercises, agonist contraction exercises, agonist contraction and hold-relax exercises). In the results of the study, intragroup comparison of the deformity angles (DA) was shown to decrease from $15.18^{\circ}$ to $13.09^{\circ}$ in the joint mobilization group (p<.05) and from $19.00^{\circ}$ to $16.83^{\circ}$ in the stretching exercises group (p<.05). However, left static foot pressure (LSFP), right static foot pressure (RSFP), left dynamic foot pressure (LDFP) and right dynamic foot pressure (RDFP) did not significantly increase or decrease after the experiment. Intergroup differences also were not statistically significant in all variables (p>.05). The current study suggests that JM and MSE are effective in decreasing the DA in patients with hallux valgus.

A Stuyd on the Load-sensitive Hydraulic Pump Control System (부하 감응형 유압 펌프 제어 시스템에 관한 연구)

  • 송창섭;이용주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.585-588
    • /
    • 1995
  • In this study, the analysis of the static and dynamic characteristics of the load-sensitive hydraulic pump control system used in the hydraulic excavator was performed by hydraulic circuit ananlysis program. Thess results was verified by the experimental data of the hydraulic excavtor system. The responses on effective parameters of system at the controllable region and the pressure variation of the pump used in hydraulic excavator system was studied to enhance the static performace of the system. the parameter enhance dynamic sharacteristics was considerd.

  • PDF

Collection characteristics of electro-static multi-staged impaction system for air pollutants removal of marine diesel engines (박용디젤기관의 대기오염 저감을 위한 전기 다단 임팩션 시스템의 집진특성)

  • YOA, Seok-Jun;KWON, Jun-Hyeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • 제51권4호
    • /
    • pp.545-552
    • /
    • 2015
  • The main object of this study is to investigate the collection characteristics of an electro-static multi-staged impaction system, experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as the inlet velocity, stage number, applied voltage and shape of discharge electrode, etc. In results, the pressure drop is shown below $148mmH_2O$ lower than that of the conventional bag filter at inlet velocity 3.46 m/s and 5 stage. For 5 stage, the collection efficiencies are to be 97.4, 99.0% with the applied voltage 0 kV at the inlet velocity 2.07, 3.46 m/s, while 98.4, 99.9% with 40 kV of a sharp edge discharge electrode. Additionally, the present system is to be considered as an effective compact system for a removal of particulate pollutants from marine diesel engines due to much higher collection efficiency and appropriate pressure drop.