• Title/Summary/Keyword: effective number

Search Result 7,611, Processing Time 0.037 seconds

Effect of planting density and seeding date on the tiller occurrence, growth and yield of sorghum (Sorghum bicolor L.)

  • Han, Tae Kyu;Yoon, Seong Tak;Jeong, In Ho;Kim, Young Jung;Yu, Je Bin;Yangjing, Yangjing;Ye, Min Hee
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.348-348
    • /
    • 2017
  • This experiment was conducted to investigate the aspect of tiller occurrence, growth and yield of sorghum according to planting density and sowing date. The subject of this experiment is to supply basic data to inhibit non-productive tillers uneconomical and cumbersome for mechanical harvesting. Also another subject was to evaluate optimum planting density and sowing date in central district area. Total number of tillers was more in 80cm ridge than 60cm ridge and it was increased as the planting distance was wider from 15cm to 30cm on the each ridge. Ratio of effective tillers was higher in 60cm ridge than 80cm ridge and it was decreased as planting distance was wider from 15cm to 30cm. The lower the planting density, the more increased total number of tillers, whereas effective tillers were decreased as planting density was high. Average of total number of tillers of three varieties was higher in sowing date of 2 May (1st sowing date), whereas ratio of effective tillers was the highest in sowing date of 23 May (2nd sowing date). Hwanggeumchal showed the highest total number of tillers (1.2 tillers), while Moktaksusu had the lowest total number of tillers (0.8 tillers) among three varieties. There were no significant difference between planting density and days to heading and ripening date from seeding. Culm length increased as planting density was high, but ear length, grains per ear and 1000 grain weight were decreased on the other hand. The highest yield of sorghum per 10a was obtained from $60{\times}20cm$ planting density among 6 planting densities.

  • PDF

Management Methods on the Growth Activation of Rhododendron mucronulatum Habitat in Mt. Biseul (비슬산 진달래군락지의 생육활성화 방안)

  • Park, In-Hwan;Cho, Kwang-Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.2
    • /
    • pp.105-114
    • /
    • 2013
  • This study was carried out to find growth increasing methods of Rhododendron mucronulatum in Mt. Biseul. 4 treatments(heavy pruning, light pruning, non-pruning+fertilization, non-pruning(control)) were used in the study area with different pruning methods. Growth characteristics of new shoot, number of creation of flower buds and leaf buds in new shoot were analysed. Significant differences were observed among the treatments and stem diameter degree. Diameter, length of new shoots and the number of flower buds, leaf buds per new shoots increased in the pruning treatments. But heavy pruning showed more effective growth increasing way than light pruning. Non-pruning and fertilization treatments were not effective to increase growth of Rhododendron mucronulatum. And pruning at the end of May was the most effective way for growth of new shoot.

An experimental study on the heat transfer characteristics in packed bed (충전층내에서의 열전달특성에 관한 실험적 연구)

  • 신현준;양한주;오수철
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.40-47
    • /
    • 1982
  • Heat transfer on packed bed is considered to be important for the effective designs of chemical reaction equipment, air conditioning system, and storage type heat exchanger, etc. Currently studies are being carried out quite actively in this field in order to increase the heat transfer efficiency. The effect of heat transfer is closely relater to materials, shapes, porosities and packing states of packed bed as well as mutual dimensional relations between particles and the container. Investigation shows that heat transfer results appear to be influenced by such parameters as fluid velocity through packed bed, mass flow, and thermal properties. It is noted that viscosity is also considered to be an important factor in this problem. In this study, effective thermal conductivities on packed bed, effects of thermal conductivity (Ke) and friction factor (Fk) according to change of porosity(.epsilon.) and Reynolds number(Reh(, and pressure loss of the fluid, are experimentally investigated. Results show that the effective thermal conductivity increases and the friction factor decreased, as against the increase of Reynolds number. But as the increase of porosity increase them both.

  • PDF

Modified Space-Vector Modulation Hysteresis Current Control Method (개선된 공간벡터형 히스테리시스 전류제어기법)

  • Jeong, An-Sik;Park, Ki-Won;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2529-2533
    • /
    • 1999
  • This paper proposes a modified hysteresis current control method based on space vector modulation. The proposed method differs from former works in that it uses effective voltage vectors instead of zero vectors while not significantly increasing the circuit complexity. The circuit uses outer band that is slightly wider than the usual current limit band (inner band) to detect the phase of current command and thereby the region information. The comparator output signals associated with the inner and outer band are used to determine the proper voltage vector that minimizes the current error and number of switching, with simple logic circuitry. The utilization of effective voltage vector is of particular importance when the ac-side emf is relatively large. Both the simulation and experiment show that the proposed method is more effective than the conventional one that uses zero vectors, in reducing the number of switching over a range of ac-side emf variation.

  • PDF

A Repeated Mapping Scheme of Task Modules with Minimum Communication Cost in Hypercube Multicomputers

  • Kim, Joo-Man;Lee, Cheol-Hoon
    • ETRI Journal
    • /
    • v.20 no.4
    • /
    • pp.327-345
    • /
    • 1998
  • This paper deals with the problem of one-to-one mapping of 2$^n$ task modules of a parallel program to an n-dimensional hypercube multicomputer so as to minimize the total communication cost during the execution of the task. The problem of finding an optimal mapping has been proven to be NP-complete. First we show that the mapping problem in a hypercube multicomputer can be transformed into the problem of finding a set of maximum cutsets on a given task graph using a graph modification technique. Then we propose a repeated mapping scheme, using an existing graph bipartitioning algorithm, for the effective mapping of task modules onto the processors of a hypercube multicomputer. The repeated mapping scheme is shown to be highly effective on a number of test task graphs; it increasingly outperforms the greedy and recursive mapping algorithms as the number of processors increases. Our repeated mapping scheme is shown to be very effective for regular graphs, such as hypercube-isomorphic or 'almost' isomorphic graphs and meshes; it finds optimal mappings on almost all the regular task graphs considered.

  • PDF

An Effective Framework for Contented-Based Image Retrieval with Multi-Instance Learning Techniques

  • Peng, Yu;Wei, Kun-Juan;Zhang, Da-Li
    • Journal of Ubiquitous Convergence Technology
    • /
    • v.1 no.1
    • /
    • pp.18-22
    • /
    • 2007
  • Multi-Instance Learning(MIL) performs well to deal with inherently ambiguity of images in multimedia retrieval. In this paper, an effective framework for Contented-Based Image Retrieval(CBIR) with MIL techniques is proposed, the effective mechanism is based on the image segmentation employing improved Mean Shift algorithm, and processes the segmentation results utilizing mathematical morphology, where the goal is to detect the semantic concepts contained in the query. Every sub-image detected is represented as a multiple features vector which is regarded as an instance. Each image is produced to a bag comprised of a flexible number of instances. And we apply a few number of MIL algorithms in this framework to perform the retrieval. Extensive experimental results illustrate the excellent performance in comparison with the existing methods of CBIR with MIL.

  • PDF

Cost-Effective Single Switch Multi-Channel LED Driver

  • Hwang, Sang-Soo;Hwang, Won-Sun;Han, Sang-Kyoo
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.319-326
    • /
    • 2015
  • In this paper, a cost-effective single switch multi-channel LED (light emitting diode) driver is proposed. While conventional LED drivers require as many non-isolated DC/DC converters as the number of LED channels, the proposed LED driver needs only one power switch and several balancing capacitors instead of expensive non-isolated DC/DC converters. Therefore, the proposed driver features a simpler structure, with a lower cost and a higher efficiency. Because its power switch can be turned off under the zero current switching condition, it has very desirable advantages such as improved electromagnetic interference characteristics and high efficiency. Moreover, it uses only a small number of DC blocking capacitors with no additional active devices for the current balancing of multi-channel LEDs. As a result, the proposed driver exhibits high reliability and is cost effective. To confirm the validity of the proposed driver, a theoretical analysis is performed, and design considerations and experimental results obtained from a prototype that is applicable to a 46" LED-TV are presented.

Convective Heat Transfer of Using an Ice Slurry in n circular pipe (아이스 슬러리의 원형관내 대류열전달에 관한 연구)

  • Jung, Dong-Ju;Choi, Eun-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.130-135
    • /
    • 2000
  • To enhance heat transfer characteristics of water, fine ice was added to it. The convective heat transfer characteristics of the ice slurry were investigated in a flow loop with a constant heat flux test section. The Nusselt number and Fanning friction coefficient of water flow were found to be similar to the expected curve by Petukhov. The Nusselt number of the ice sin flow was higher than the Nusselt number of water. Effective thermal capacity of the 10.84% ice slurry was found to have 2.39 times of the thermal capacity of water.

  • PDF

A study on convective heat transfer with microcapsulated lauric acid slurry in circular pipe (미립피복 로릭산 슬러리의 관내 대류 열전달에 관한 연구)

  • Jeong, Dong-Ju;Choi, Eun-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1554-1559
    • /
    • 2003
  • The objective of the present study is to reveal thermal characteristic of microcapsulated lauric acid slurry, which have high latent heat during phase change from solid to liquid, in circular pipe. Test were performed with microcapsulated lauric acid slurry in a heating test section with a constant heat flux boundary condition. Local Nusselt number and the effective thermal capacity were measured. As the size of microcapsulated lauric acid were increased, Local Nusselt number of microcapsulated lauric acid slurry were increased. The effective thermal capacity of microcapsulated lauric acid slurry was 0.5 times than it of water

  • PDF

Designing efficient fuzzy inference rules for the sensory evaluation (관능평가를 위한 효율적인 퍼지추론 규칙의 설계)

  • 이진춘
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.6 no.1
    • /
    • pp.61-69
    • /
    • 2001
  • This study concerns designing effective fuzzy inference rules, which can be used to evaluate other experiment sets for sensory tests. The number of fuzzy inference rules might be determined by the fuzzy division of variables. For the more the number of fuzzy division does not mean the more effectiveness, the number of inference rules should be reduced to improve efficiency of inference engine of expert system. This study verified that its suggested method and inference rules are effective in comparison with the existing studies.

  • PDF