• 제목/요약/키워드: effective magnetization

검색결과 85건 처리시간 0.026초

함정에 의해 발생하는 수중 지자계 외란신호 분리방법에 대한 연구 (Study on Separating Underwater Earth Field Anomaly Generated by a Ship)

  • 이강진;양창섭;정현주;김동훈
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1412-1417
    • /
    • 2007
  • Magnetic anomaly generated around a ship is mainly due to the permanent magnetization(PM) and induced magnetization (IM) remaining on the hull. It is very difficult to predict the direction and its magnitude of the permanent magnetization distributed over the hull, that is caused by mechanical or thermal stress. In this paper, an effective method is proposed to separate two components, the one produced by PM and the other by IM, from the underwater earth field signal distorted by the ferromagnetic material of the ship. The method can easily provide the two kinds of magnetic anomaly through exploiting experimental results and 3D electromagnetic field analyses even though the PM distribution on the hull is not known. To validate the proposed method, a model ship is manufactured and tested. The results would be of much help to basis research for securing safe navigation of a ship against dangerous factors in underwater.

철심의 자화특성을 고려한 자속구속형 초전도 사고전류제한기의 특성 분석 (Characteristic Analysis of a Flux-Lock Type SFCL Considering Magnetization Characteristic of Iron Core)

  • 임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제20권11호
    • /
    • pp.995-999
    • /
    • 2007
  • We investigated the characteristics of a flux-lock type superconducting fault current limiter(SFCL) considering magnetization characteristic of iron core. The flux-lock type SFCL, like other types of SFCLs using the iron core, undergoes the saturation of the iron core during the initial fault time. Therefore, if the design to prevent the saturation of the iron core is considered, the effective fault current limiting operation can be achieved. Through the analysis for its equivalent circuit including the magnetization characteristic of the iron core, the limiting impedance of the flux-lock type SFCL was drawn. The magnetization currents and the limited currents of SFCL, which were dependent on the winding direction and the turns' ratio between two coils, were investigated from the short circuit experiment. It was confirmed that their experimental results agreed with the analysis ones.

단일·이중소자를 이용한 자기결합 초전도 한류기의 자화특성 및 누적에너지 비교분석 (Comparative Analysis on Magnetization Characteristics and Stored Energy of Magnetically Coupled SFCLs Using Single and Double HTSC Elements)

  • 최상재;김보희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제30권2호
    • /
    • pp.101-105
    • /
    • 2017
  • In this paper, the magnetization characteristics and the stored energy of magnetically coupled superconducting fault current limiter (SFCL)s using single and double high-Tc superconducting (HTSC) elements were compared. To analyze the magnetization characteristics and the stored energy, the magnetizing current and the flux linkage, which were derived from the electrical equivalent circuit of the SFCL using single and double HTSC elements, were calculated from the voltages and the current measured in the short-circuit tests. Through the comparative analysis on the magnetization characteristics and the stored energy for SFCL using sing and double HTSC elements, the magnetically coupled SFCL using double HTSC elements was shown to be more effective than the SFCL using single HTSC element from the point of view of the magnetic saturation.

자화손실 측정값으로부터 추정한 YBCO CC의 임계전류밀도 평가 (Estimation of critical current density of a YBCO coated conductor from a measurement of magnetization loss)

  • 이세연;박상호;김우석;이지광;최경달
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권3호
    • /
    • pp.16-20
    • /
    • 2010
  • For large scale power applications of HTS conductor, it is getting more important to have a stacked HTS coated conductor with low loss and large current capacity. But it was not easy to measure some electric properties. Stabilizer free YBCO CC for striated/ stacked conductors is easily burned out during the measurement of the critical current density because it has no stabilizer and it is difficult to set-up the current lead and voltage taps because it has many pieces of YBCO CC in a conductor. Instead of direct measuring the critical current of a stacked HTS coated conductor, indirect estimation from measuring a magnetization loss of HTS coated conductor could be useful for practical estimation of the critical current. The magnetization loss of a superconductor is supposed to be affected by a full penetrating magnetic field, and it tends to show an inflection point at the full penetrating magnetic field when we generate the graph of magnetization loss vs. external magnetic field. The full penetrating magnetic field depends on the shape of the conductor and its critical current density, so we can estimate the effective critical current density from measuring the magnetization loss. In this paper, to prove the effectiveness of this indirect estimation of the critical current, we prepared several different kinds of YBCO CC(coated conductor) including a stacked conductor short samples and measured the magnetization losses and the critical currents of each sample by using linked pick up coils and direct voltage measurement with transport current respectively.

Magnetization Transfer Contrast Angiography for Organized Thrombosed Intracranial Aneurysm in TOF MR Angiography: a Case Report

  • Kang, Dong-Hun;Lee, Hui Joong
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권4호
    • /
    • pp.266-271
    • /
    • 2018
  • A 66-year-old woman was referred for treatment of incidental detection of two intracranial aneurysms. Time-of-flight MR angiography (TOF MRA) revealed two aneurysms at the M1 segment of the right middle cerebral artery, and clinoid segment of left internal carotid artery, respectively. On digital subtraction angiography, there was a saccular aneurysm on the left internal carotid artery, but the other aneurysm was not detected on the right middle cerebral artery. Based on comprehensive review of imaging findings, organized thrombosed aneurysm was judged as the most likely diagnosis. In the presented report, magnetization transfer (MT) pulse to TOF MRA was used, to differentiate aneurysm-mimicking lesion on TOF MRA. We report that MT technique could be effective in differentiating true aneurysm, from possible T1 high signal artifact on TOF MRA.

Magnetic Properties of Fe3-x MnxO4 Thin Films by FMR

  • Kim, Ki-Hyeon;Kim, Young-Ho;Ha, Tae-Wook;Lee, Jeong-Sik;Park, Mann-Jang
    • Journal of Magnetics
    • /
    • 제2권2호
    • /
    • pp.38-41
    • /
    • 1997
  • Spinel ferrite thin films Fe3-x MnxO4 (x=0.000, 0.006, 0.0010, 0.015, 0.023) were prepared on the coverglass by ferrite plating technique. To investigate the uniaxial anisotrpy of the samples, the saturation and effective magnetization of the thin films were measured by VSM(vibrating sample magnetometer) and FMR(ferromagnetic resonance) measurements respectively. The spectroscopic splitting g factor were estimated from the ferromagnetic resonance curves. For x=0.000, 0.006, the effective magnetization was measured of temperatures form T=77 K to T=300 K. The results were analyzed in terms of Bloch's law Ms(T) = Ms(0) (1-BT3/2-CT5/2). The Bloch coefficient B, C were determined by fitting. Ms(0) was obtained by extrapolating Meff to 0 K. From this result, the spin wave stiffness constants D was also determined.

  • PDF

변압기를 이용한 저항형 고온초전도 전류제한기의 한류 특성 (Fault Current Limiting Characteristics of Resistive Type SFCL using Transformer)

  • 임성훈;최효상;고석철;이종화;강형곤;한병성
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.288-290
    • /
    • 2003
  • The transformer is expected to be an essential component of resistive type superconducting fault current limiter (SFCL) for both the increase of voltage ratings in SFCL and the simultaneous quench due to different critical current between HTSC elements. However, for the design to prevent the saturation of iron core and the effective fault current limitation, the analysis for operation of SFCL with consideration for the magnetization characteristics are required. In this paper, the fault current limiting characteristics related with the magnetization ones were investigated through the variation of the ratio of the number of turns in the 1st and the 2nd windings. The proper design condition with variation of the number of turns to make the effective fault current limiting operation could be determined.

  • PDF

NiFe 박막의 두께에 따른 강자성 공명 특성 분석 (Thickness Dependence of Ferromagnetic Resonance Properties in NiFe Thin Films)

  • 김동영;윤석수
    • 한국자기학회지
    • /
    • 제23권2호
    • /
    • pp.37-42
    • /
    • 2013
  • 본 연구에서는 NiFe 박막 시편을 마그네트론 스퍼터링 방법으로 제조하여 박막면 기준으로 수직면(out-of-plane) 자기장 방향과 수평면(in-plane) 자기장 방향에 따른 강자성 공명 자기장을 측정하였다. 수직면 자기장 방향에 따른 강자성 공명 자기장으로부터 유효자화량($M_{eff}$)을 도출하였으며, NiFe 두께에 따른 $M_{eff}$의 감소는 $K_s=-0.23\;erg/cm^2$의 값을 갖는 표면 이방성 상수에 기인하였다. 또한 수평면 자기장 방향에 따른 강자성 공명 자기장으로부터 수평면에서의 일축 이방성 자기장을 도출하였다. 한편, 일축 이방성 에너지의 자화 용이축이 두께가 감소함에 따라 시편 제조 시 인가한 자기장의 반대 방향으로 회전하고 있었으며, 이러한 현상은 시편 표면에 형성된 NiFeO의 반강자성 특성에 의한 현상으로 설명하였다.

저온에서 Hoya FR5 및 FR4 유리의 Faraday 회전 (Faraday Rotation of the Hoya FR5 and FR4 Glasses at Cryogenic Temperature)

  • 이현곤;원영희;이경수
    • 한국광학회지
    • /
    • 제6권4호
    • /
    • pp.352-358
    • /
    • 1995
  • $Tb^{3+}$이온이 첨가된 Hoya FR5 유리와 $Ce^{3+}$이론이 첨가된 Hoya FR4 유리의 Faraday 회전과 자기화를 4.2K-10K 저온 영역에서 자기장을 80kG까지 증가시키면서 온도 T와 자기장 H의 함수로 측정하였다. 사용파장은 아르곤 레이저의 514.5nm였다. H/T> $5kG.K^{-1}$ 이상에서 나타난 자기화 및 Faraday 회전의 포화현상을 상자성체 양자이론으로 해석할 수 있었다. 계산된 맺음변수들로부터 $Ce^{3+}$ 유리의 큰 Verdet 상수는 $4f\rightarrow5d$궤도 유효 전기쌍극자 전이효과에 기인되고 $Tb^{3+}$ 유리의 큰 Verdet 상수는 자기화에 기인됨을 알 수 있었다.

  • PDF

Thermomagnetic Characteristics of the Hard Magnetic Materials with a Fine Microstructure due to a HDDR Process

  • Kwon, H.W.;Kim, Yoon-B.;Jeung, W.Y.
    • Journal of Magnetics
    • /
    • 제4권1호
    • /
    • pp.26-32
    • /
    • 1999
  • The HDDR process can be used as an effective means of processing of the coercive Nd-Fe-B-type or the Sm2Fe17Nx materials. The HDDR (hydrogenation, disproportionation, desorption, recombination) processed materials are feartured with a very fine microstructure. The thermomagnetic characteristics of the Nd-Fe-B-type or the Sm2Fe17Nx materials with fine microstructure due to the HDDR process were investigated. It has been found that the fine-microstructured hard magnetic materials showed an unusual TMA (Thermomagnetic analysis) tracting featured with a low and constant magnetization at lower temperature range and a peak just below their Curie temperatures when a low external field is applied. This thermomagnetic characteristic was immediate particularly in the TMA with a low applied field. This thermomagnetic characteristic was interpreted in terms of the competition between two counteracting effects; the decrease in magnetication due to the thermal agitation at an elevated temperature and the increase in magnetization resulting from the rotation of magnetization of the fine grains comparable to a critical single domain size due to the decreased magnetocrystalline anisotropy at an elevated temperature.

  • PDF