• Title/Summary/Keyword: effective distance

Search Result 1,923, Processing Time 0.026 seconds

Evaluation of Seismic Load Level in Korea based on Global Recorded Earthquake Ground Motions (세계지진기록에 근거한 우리나라의 지진하중 평가)

  • Hwang, Kyung Ran;Lee, Han Seon;Kim, Sung Jig
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.247-256
    • /
    • 2015
  • This paper briefly introduces the design seismic loads in Korea (KBC 2009). Then, over 10,000 recorded earthquake ground accelerograms, with their magnitude ranging from 4.0 to 8.0 and their epicentral distance ranging from 0 to 200 km, were used to examine the appropriateness of seismic load defined in Korea known as a low-to-moderate seismicity region. The following conclusions are drawn based on the results: (1) The effective peak ground accelerations (EPA) of recorded earthquake accelerograms under $M{\leq}6.0$ and $R{\geq}15km$ appear to be less than that of MCE in Korea for all site conditions defined in KBC 2009. (2) The design spectrum (two-thirds of the intensity of MCE) in KBC 2009 is comparable to those of earthquake records in the magnitude 6 - 7 and the epicentral distance less than 50 km. Therefore, (3) the intensity of Korean design earthquake is considered to be overly high since the Korea peninsula is generally conceived to be a low-seismicity region.

The Influence of Optical Porosity of Tree Windbreaks on Windward Wind Speed, Erosive Force and Sand Deposition

  • Dafa-Alla, M.D.;Al-Amin, Nawal K.N.
    • Journal of Forest and Environmental Science
    • /
    • v.32 no.2
    • /
    • pp.212-218
    • /
    • 2016
  • The research was conducted windward of an irrigated Acacia amplicips Maslin windbreak established to protect As Salam Cement Plant from winds and moving sands. Two belts with approximate optical porosities of 50% and 20% were studied in River Nile State, Sudan. The research aimed at assessing the efficiency of the two belts in wind speed reduction and sand deposition. Research methods included: (i) estimation of optical porosity, (ii) measurements of windward wind speeds at a control and at distances of 0.5 h (h stands for windbreak height), 1 h and 2 h at two vertical levels of 0.25 h and 0.5 h, (iii) estimation of relative wind speeds at the three positions (distance and height) at windward and (iv) estimation of wind erosive forces and prediction of zones of sand deposition. Results show that while the two belts reduced windward wind speeds at the two levels for the three distances, belt II was more effective. Nearest sand deposition occurred at 2 h and 1h windward of belt II and belt I, respectively, at level 0.25 h. At level 0.5 h, sand was deposited only at 2 h windward of belt II and no sand deposition occurred windward of belt I. The study concludes that less porous windbreaks are more effective in reducing wind speed and in depositing sand in windward direction at a distance of not less than twice the belt height.

Lateral Displacement Analysis of Concrete Electric Pole Foundation Grounds (배전용 콘크리트전주 기초지반의 횡방향변위 분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.42-49
    • /
    • 2009
  • The effects of various forces acting on concrete pole are analyzed using finite element method how the forces affect on ground displacement. The soil types, wind load location of anchor block embedded depth of pole, and distance between poles are varied to find out effects on lateral displacement. Anchor block is effective when it is located at 1/4 of embedded depth The displacement is decreases as elastic modulus increases. Concrete reinforcement for loosened ground is necessary for double poles because double poles cause large excavation. When embedded depth ratio decrease, lateral displacement increase as closer to ground surface. Large embedded depth is effective to reduce lateral displacement, and the distance between poles is not much large factor.

A Study for Accommodation Power on the Basis of Near Power and Correction Power for distance (근용 도수와 원용 교정도수를 근거로 한 조절력에 관한 연구)

  • Lee, Jeung-Young;Park, Eun-Kyu;Seo, Jeung-Ik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.107-110
    • /
    • 2007
  • Analysis of accommodation amplitude has been conducted for 137 adults, living in rural area, aged from their fifties to eighties. The methods included measurement of correction power for distance via auto-refractometer, measurement of near power based on trial frame and trial lens set, and calculation of effective accommodation amplitude using 1/2 and 2/3 of the maximum accommodation amplitude. The research results for participants aged in their fifties, sixties, seventies, and eighties showed 1.84~2.46D, 1.55~2.06D, 1.43~1.90D, and 1.22~1.62D respectively. It is relatively higher than the existing knowledge regarding accommodation amplitude associated with age.

  • PDF

A Representation and Matching Method for Shape-based Leaf Image Retrieval (모양기반 식물 잎 이미지 검색을 위한 표현 및 매칭 기법)

  • Nam, Yun-Young;Hwang, Een-Jun
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.11
    • /
    • pp.1013-1020
    • /
    • 2005
  • This paper presents an effective and robust leaf image retrieval system based on shape feature. Specifically, we propose an improved MPP algorithm for more effective representation of leaf images and show a new dynamic matching algorithm that basically revises the Nearest Neighbor search to reduce the matching time. In particular, both leaf shape and leaf arrangement can be sketched in the query for better accuracy and efficiency. In the experiment, we compare our proposed method with other methods including Centroid Contour Distance(CCD), Fourier Descriptor, Curvature Scale Space Descriptor(CSSD), Moment Invariants, and MPP. Experimental results on one thousand leaf images show that our approach achieves a better performance than other methods.

Effective Localized-Voltage Control Scheme using the Information from Pilot Bus (Pilot Bus의 정보를 이용한 효율적인 지역별 전압제어)

  • Song, Sung-Hwan;Yoon, Yong-Tae;Moon, Seung-Il;Lee, Ho-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.505-513
    • /
    • 2006
  • One of the major reasons for recent blackout, like August 14, 2003 blackout in the US and Canada has been insufficient voltage/reactive power support. For the stable reactive power management, a new approach for the voltage monitoring and control structure is required in the market environment. This paper proposes the effective localized-voltage control scheme using the information from pilot buses at each zone. In this paper, the steady state voltage monitoring and control (SSVMC) is adopted and illustrated for the voltage control scheme during steady state because it is thought as the systemic algorithm to explain voltage profile phenomenon before and after contingencies. And the concept of electrical distance is applied to simultaneously achieve both clustering the voltage control zone, and selecting the pilot bus as the representative node at each control zone. Applying SSVMC based on the structure with clustering and pilot bus enables system operators to monitor and understand the system condition much more easily, to monitor and control the voltage in real-time more manageably, and to respond quickly to a disturbance. The proposed voltage control scheme has been tested on the IEEE 14-bus system with the numerical analysis to examine the system reliability and structure efficiency.

A Study of Trials on Material Integration Pool System for Logistics Rationalization - Basing on the Improvement a precedent about Logistics System of 'A' Enterprise - (물류혁신을 위한 자재통합공동물류 시행에 관한 연구(A사 물류시스템 개선사례를 중심으로))

  • Won, You-Jon;Kang, Kyung-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.373-383
    • /
    • 2006
  • Logistics is one of the most important factors to manage a stream of materials in economic environment. Establishing effective logistics system needs to consider some constraints which are fluctuation of materials volume, a long distance between makers and consumers, one way logistics and small quantity batch production. It is estimated that Unit Load System should be a powerful method to cope with those problems. It helps to realize the key issues which are Standardization and Logistics Pool System The Material Unification of Logistics System is able to participate in all kinds of industries including manufacturing, distribution and logistics. This system has some merits which are a long distance transportation cost down, product recovery, and treatment in the unbalance of demand and supply caused by unstable materials volume. Four strategies of Material Logistics Model are Packing Rationalization, Logistics Pool System, JIT System application and establishing effective infrastructure. The Material Unification Of Logistics System based on Unit Load System achieves efficiency of logistics and largely decreases moving cost.

  • PDF

Analysis of the Protective Distance of Low-Voltage Surge Protective Device(SPD) to Equipment (저압용 서지 보호 장치(SPD)의 보호 거리 해석)

  • Lee, Jung-Woo;Oh, Yong-Taek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.28-34
    • /
    • 2012
  • Installing surge protection devices for a low-voltage system is important to ensure the survival of electric or electronic devices and systems. If surge protection devices (SPD) are installed without consideration of the concept of lightning protection zones, the equipment to be protected might be damaged despite the correct energy coordination of SPDs. This damage is induced by the reflection phenomena on the cable connecting an external SPD and the load protected. These reflection phenomena depend on the characteristics of the output of the external SPD, the input of the loads, and the cables between the load and the external SPD. Therefore, the SPD has an effective protection distance under the condition of the specific load and the specific voltage protection level of SPD. In this paper, PSCAD/EMTDC software is used to simulate the residual voltage characteristics of SPD Entering the low-voltage device. And by applying a certain voltage level, the effective protection distances of SPD were analyzed according to the each load and length of connecting cable, and the effectiveness of SPD were verified.

Shape Descriptor for 3D Foot Pose Estimation (3차원 발 자세 추정을 위한 새로운 형상 기술자)

  • Song, Ho-Geun;Kang, Ki-Hyun;Jung, Da-Woon;Yoon, Yong-In
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.2
    • /
    • pp.469-478
    • /
    • 2010
  • This paper proposes the effective shape descriptor for 3D foot pose estimation. To reduce processing time, silhouette-based foot image database is built and meta information which involves the 3D pose of the foot is appended to the database. And we proposed a modified Centroid Contour Distance whose size of the feature space is small and performance of pose estimation is better than the others. In order to analyze performance of the descriptor, we evaluate time and spatial complexity with retrieval accuracy, and then compare with the previous methods. Experimental results show that the proposed descriptor is more effective than the previous methods on feature extraction time and pose estimation accuracy.

Retrieval of High-Resolution Grid Type Visibility Data in South Korea Using Inverse Distance Weighting and Kriging

  • Kang, Taeho;Suh, Myoung-Seok
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.1
    • /
    • pp.97-110
    • /
    • 2021
  • Fog can cause large-scale human and economic damages, including traffic systems and agriculture. So, Korea Meteorological Administration is operating about 290 visibility meters to improve the observation level of fog. However, it is still insufficient to detect very localized fog. In this study, high-resolution grid-type visibility data were retrieved from irregularly distributed visibility data across the country. To this end, three objective analysis techniques (Inverse Distance Weighting (IDW), Ordinary Kriging (OK) and Universal Kriging (UK)) were used. To find the best method and parameters, sensitivity test was performed for the effective radius, power parameter and variogram model that affect the level of objective analysis. Also, the effect of data distribution characteristics (level of normality) on the performance level of objective analysis was evaluated. IDW showed a relatively high level of objective analysis in terms of bias, RMSE and correlation, and the performance is inversely proportional to the effective radius and power parameter. However, the two Krigings showed relatively low level of objective analysis, in particular, greatly weakened the variability of the variables, although the level of output was different depending on the variogram model used. As the level of objective analysis is greatly influenced by the distribution characteristics of data, power, and models used, care should be taken when selecting objective analysis techniques and parameters.