• 제목/요약/키워드: effective discharge

검색결과 1,009건 처리시간 0.028초

자연형 호안공법을 적용한 소하천의 수리특성 분석 (Analysis of Hydrodynamic Characteristics Apply to Nature-Friendly Stream Protection Method)

  • 이강석;박종화;연규방
    • 한국관개배수논문집
    • /
    • 제17권2호
    • /
    • pp.71-81
    • /
    • 2010
  • Stream Pilot Project, which began in May 2003 and finished in December 2003, was selected to develop effective methods applicable to nature-like streams. Stream restoration projects aim to maintain or increase ecosystem goods and services while protecting downstream and coastal ecosystems. Fields environmental monitoring such as flow discharge and precipitation were conducted along the Idong stream for amount of channel zone change in 2007. This study selected three monitoring positions to measure the water level and discharge of flowing water. A stage-discharge relation is obtained from direct discharge measurements for three stations by fitting an empirical relationship to the data set. Since discharge measures are made only for low flow conditions, a curve of discharge against stage can then be built by fitting these data with a power curve. And this study used data obtained from floodmark checkup as well as HEC-RAS model to analyze the hydrodynamic characteristics of monitoring sites. Reach-averaged hydraulic parameters for the supply reach were calculated from the small area's HEC-RAS model for Idong stream, and a HEC-RAS model used to analyze hydraulics for a period in 2007, after the stream was considered bank stabilization.

  • PDF

밧데리 개별 제어 방식에 의한 소규모 독립형 태양광 발전 시스템의 특성 개선 (The Improved Characteristics of the Stand-alone PV System by the Independent Battery Control Method)

  • 강신영;이양규;김광헌
    • 전력전자학회논문지
    • /
    • 제7권5호
    • /
    • pp.482-489
    • /
    • 2002
  • 본 연구는 PV모듈, 밧데리, 충·방전시스템 등으로 구성된 태양광 가로등을 대상으로 소규모 독립형 태양광 발전 시스템(SPVS)을 연구하였다. 태양전지의 발전 효율을 증가시키고 밧데리를 효율적으로 사용할 수 있도록 하기 위해 병렬로 연결된 밧데리를 개별적으로 제어할 수 있는 시스템을 제안하였다. 제안된 시스템은 기존의 방식에 비해 밧데리 충전효율이 증가되고 충방전 횟수를 50%정도 감소시킬 수 있다. 또한 병렬 연결된 전지를 개별적으로 충전 혹은 방전 모드로 제어함으로서 일부 밧데리 고장시에도 일정기간 동안은 정상동작이 가능하고, 밧데리의 고장이 정상적인 밧데리로 전이되는 것을 예방할 수 있어 시스템 유지 보수비용을 줄일 수 있어 태양광 가로등에 적용할 경우 비용절감이 가능할 것으로 예상된다.

방전공격과 방전극 형상이 오존발생농도에 미치는 영향 (Effects of Corona Electrode Shape and Discharge Gap Spacing on Ozone Concentration)

  • 박승록;이재찬;정성진;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권4호
    • /
    • pp.169-175
    • /
    • 2001
  • Ozone has been widely applied to many industrial fields because of its strong oxidation power, Therefore, the studies have been carried out for the methods on an effective and high concentration ozone generation. The silent or surface discharge type ozone generators have been mainly used for high concentration ozone generation in many fields of applications. But these two types of ozone generators have shortcomings to be improved. In this study, the ozone generator which improved the shortcomings of above ozone generators was proposed and fabricated for the high concentration ozone generation. And the proposed ozone generator could generate the surface and barrier discharge simultaneously. For this purpose, a mesh type discharge electrode was proposed and studied as a function of the widths output maximum ozone concentration of 2.96[vol%] was obtained at 5.6[kV], 830[mA], for 0.3[mm] width and 0.8[mm] vacancy of the mesh electrode and gap spacing of 0.65[mm] respectively.

  • PDF

평면형 구리 - 탄소 전극의 형태별 재기전압 특성 및 파형 패턴에 관한 연구 (Study on Restriking Transient Voltage Characteristics and Waveform Patterns of Planar Copper-Carbon Electrodes using Forms)

  • 임종민;최충석
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.1-6
    • /
    • 2020
  • 본 논문은 직렬 아크 방전이 진행될 때의 전압 및 전류 파형을 실시간 측정하였다. 아크 방전의 방사 패턴을 분석한 결과 간헐적인 방전, 아크의 성장, 발열부의 생성, 플룸의 발생, 적열부 형성 순서로 진행되는 것을 알 수 있었다. 직렬 아크 방진이 진행될 때 전류 및 전압 파형은 정현파와 같은 주기성을 나타냈다. 그리고 + 파형에서 - 파형으로 바뀔 때와 - 파형에서 + 파형으로 바뀔 때 파형의 재기전압이 발생하는 것이 확인되었다. 방전이 진행될 때 1 s 동안에 발생하는 열량은 약 0.317 mJ이고, 600 s 동안에 약 190 mJ의 열이 발생하는 것으로 해석되었다. 그리고 단락 지속시간은 약 1.66 ms인 것으로 해석되었으며, 동일한 주기에서 전압 파형은 49.9 V까지 전위가 상승하는 것을 알 수 있었다. 또한, 방전이 진행될 때 전류의 실효치는 약 1.72 A이고, 최대치는 약 2.53 A로 분석되었다. 그리고 전압의 실효치는 약 42.8 V로 계산되었고, 최대치는 약 208 V로 측정되었다.

이종방전 중첩에 의한 방전 플라스마반응기의 효율개선의 시도 - 연면.직류코로나 방전 중첩형 반응기의 특성 - (A Trial for Improvement of Energy Efficiency of Plasma Reactor by Superposing Two Heterogeneous Discharges - Characteristics of Surface and Corona Discharge Combined Plasma Reactor -)

  • 우인성;;황명환
    • 한국안전학회지
    • /
    • 제15권3호
    • /
    • pp.66-70
    • /
    • 2000
  • In order to cope with environmental problems caused by harmful gases emitted from various industrial sources, a new technology which employs discharge plasma formed in ordinary atmospheric pressure has been intensively investigated in many industrialized nations. Although a plenty of useful outcomes and suggestions have been made public by scientists in this field, few commercial products which effectively decompose pollutant gases have appeared as yet. This is partly because that the energy efficiency of a most effective plasma reactor has not reached a satisfactory level in comparison with those of devices using conventional technologies. In an attempt to solve the problem mentioned above, we noticed to combine heterogeneous electrical discharges. This concepts is based on that each plasma reactor has its specific spatial region in which chemical reaction are active and by electrically affected with another reactor of different type, the activated region would increase - which may lead to cutting down the energy consumption. To prove this concept experimentally, two different discharge equipments, a plane ceramic-based surface discharge electrode and a corona electrode with tungsten needle may, are selected and combined to fabricate a hybrid plasma reactor. The results are summarized as follows; (1) Ozone concentration generated in the plasma region drastically increases when the positive corona discharge is added to the surface discharge. The rate of increase of ozone depends on the frequency of the surface discharge. The negative corona, however, does not contribute to the improvement of the ozone generation. (2) NO(nitrogen monoxide) decomposition rate also improves by simultaneously applying the surface and the positive corona discharges. The effect of the corona superposition is more evident when the level of the surface discharge is moderate. (3) By adjusting the corona level, the net energy efficiency during NO decomposition improves in comparison with the simple surface discharge reactor.

  • PDF

미계측 지점에서의 유출 모의 및 예측 (Runoff Simulation and Forecasting at Ungaged Station)

  • 안상진;최병만;연인성;곽현구
    • 한국수자원학회논문집
    • /
    • 제38권6호
    • /
    • pp.485-494
    • /
    • 2005
  • 유량과 수질의 관계를 분석하는 것은 매우 중요하다. 하천의 실시간적 관리를 위해서는 유량과 수질의 측정이 동일한 지점에서 동시간적으로 이루어져야 보다 효과적이다. 그러나 수질자동측정망 지점과 T/M 수위관측소가 원거리에 위치한 경우들이 있으며, 평창강 수질자동측정망 지점이 그 중 하나이다. 이러한 지점에서는 보다 정확한 유량 산정과 이를 활용한 예측 프로그램이나 시스템이 요구된다. 이번 연구에서는 미계측 지점인 평창강 수질자동측정망 지점에 유량예측 신경망 모형을 적용하고, 적용성을 검토하기 위해 WMS 모형의 모의결과와 비교하였다. WMS 모형은 첨두유량이 작고, 수문곡선이 단조로운 사상에 적합한 것으로 나타났다. 신경망 모형의 유출량 예측값은 비유량과 WMS 모형의 모의값에 근사하였으며, 미계측 지점에서의 유출량 변화성향을 잘 반영하는 것으로 나타났다.

소각기의 배기가스 유로에 이젝터를 적용한 시스템의 성능 분석 (Performance Analysis on the Ejector System in Flue-gas Discharge Channel of Marine Incinerator)

  • 윤상국;장호길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권6호
    • /
    • pp.773-778
    • /
    • 2011
  • 선박용 소각기는 각종 폐기물의 연소로 인한 해양환경 오염 우려로 국제해사기구에 의한 기준이 점점 강화되어지고 있다. 본 연구는 배기가스의 온도를 낮추고 연소실의 연소가스가 원활하게 배출되도록 배기가스의 배출 유로를 3개로 하고, 배기통로 내에 보조 이젝터를 설치한 시스템의 성능 향상에 대하여 Ansys를 사용하여 유동 해석을 수행하였다. 해석결과, 배기가스 유로의 다채널화에 의하여 배기가스 온도가 국제해사기구 기준보다 낮게 유지되었으며, 통로에 설치한 보조 이젝터가 배기가스 배출에 매우 효과적인 장치인 것으로 분석되었다.

77K 이하 극저온 상에서의 부분방전 특성 분석 (Analysis of Partial Discharge Characteristics at Cryogenic Temperature below 77K)

  • 이상화;김복렬;신우주;이방욱;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1562-1563
    • /
    • 2011
  • Partial discharge measurement is one of the effective diagnostic techniques to predict abnormal high voltage dielectric insulation conditions of the electric equipments. Recently partial discharge diagnostic techniques were also utilized to evaluate the cryogenic dielectric insulation of high temperature superconducting electric equipment in liquid nitrogen. Generally, liquid nitrogen at 77 K is used used as the cryogenic and dielectric media for many high temperature superconducting high voltage applications. When a quench in the superconductor occurs, bubbles are generated which can affect the dielectric properties of the liquid nitrogen. So in order to reduce the bubble formation, subcooled nitrogen was also employed for this purpose. In this work, investigation of partial discharge characteristics of subcooled liquid nitrogen were conducted in order to clarify the retardation of partial discharge initiation voltage according to the different subcooling temperature of liquid nitrogen. And also the relation of partial discharge phenomena and the activities of bubbles were analyzed. It was observed that PD inception voltages shows rather different characteristics according to the decrease of subcooling temperature and the activities of bubbles were strongly influenced by temperature of the subcooled liquid nitrogen.

  • PDF

관형 코로나 방전전극을 이용한 이온풍속의 최대화 (An Maximization of Ionic Wind Utilizing a Cylindrical Corona Electrode)

  • 정재승;문재덕
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2256-2261
    • /
    • 2010
  • A corona discharge system with needle point or wire type corona electrode has been well used as an ionic wind blower. The corona discharge system with a needle point electrode produces ions at lower applied voltage effectively. However, the corona discharge on the needle point electrode transits to the arc discharge at lower voltage, and it is hard to obtain the elevated electric field in the discharge airgap for enhancing the ion migration velocity due to the weak Coulomb force. A cylindrical corona electrode with sharp round tip is reported as one of effective corona electrode, because of its higher breakdown voltage than that of the needle electrode. A basic study, for the effectiveness of cylindrical electrode shape on the ionic wind generation, has been investigated to obtain an maximum wind velocity, which however is the final goal for the real field application of this kind ionic wind blower. In this paper, a parametric study for maximizing the ionic wind velocity utilizing the cylindrical corona electrode and a maximum ion wind velocity of 4.1 m/s were obtained, which is about 1.8 times higher than that of 2.3m/s obtained with the needle corona electrode from the velocity profile.

HDIV를 위한 PDP의 표시방전특성에 관한 연구 (A Study on the Display Discharge Characteristics of PDP for the HDTV)

  • 염정덕
    • 조명전기설비학회논문지
    • /
    • 제19권4호
    • /
    • pp.39-46
    • /
    • 2005
  • 본 연구는 3 전극 교류구동형 PDP의 ADS구동방식에 관한 것으로 휘도의 저감이 없는 안정적인 표시방전이 가능한 최소의 어드레스와 표시방전 유지펄스의 폭을 도출하는 것이다. 실험결과로부터 어드레스 펄스폭이 $1.5[{\mu}s]$이 상만 되면 효과적인 어드레스 방전이 가능하였고 35[V] 어드레스 동작마진을 얻을 수 있었다. 또한, 표시방전 유지펄스의 폭이 $2[{\mu}s]$이상 되면 25[V]의 동작마진을 가지고 안정적인 표시방전의 유지가 가능하였다. 이 조건들을 수평 주사선수 1080라인의 Full-HDTV급 PDP에 적용할 경우 8개의 서브필드와 총 1420개의 표시방전 유지펄스를 사용할 수 있다.