Numerical Analysis of Pressure Distribution in Piston-Cylinder Unit for Accurate Pressure Measurement (유압측정을 위한 피스톤-실린더 간격내의 압력분포에 대한 수치해석)

  • U, Sam-Yong;Park, Jong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.9
    • /
    • pp.2909-2915
    • /
    • 1996
  • Precise and accurate pressure measurements are obtained using deadweight piston gauges. Pressure distribution and elastic distortion in the piston-cylinder unit are the leading factors in determination of effective area. The distortion depends upon the pressure distribution in the clearance between piston and cylinder and those are coupled each other. Considering the viscosity pressure relation of oil and governing flow equation in the clearance, a new numerical iterative algorithm is developed. The disagreement between the monotonous and sharp pressure profiles is an indication that the pressure profile will be different for each piston and cylinder unit due to material variances.

Reliability Analysis of a Two-Link Robot Manipulator Due to Tolerances (2관절 로봇팔의 공차로 인한 신뢰도 해석)

  • ;Lee, S. J.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.9
    • /
    • pp.2257-2264
    • /
    • 1994
  • A method to evaluate the position performance for a stochastically defined planar robot manipulator is presented. Performance is defined as the operational reliability based upon the positional errors of the manipulator tip. An analytical method is developed and applied to a two-link robot manipulator through forward kinematics. This study includes uncertainties in the link length, pin center location and radial clearance. By virtue of the effective link length model, only the nominal manipulator model and statistical information on the uncertainties are required. The results from the analytical method is compared to those from the Monte Carlo simulation.

Effect of Piston Shape on the Lubrication Characteristics of Hydraulic Piston Pump and Motor (피스톤 형상이 유압피스톤 펌프$cdot$모터의 윤활특성에 미치는 영향)

  • 이정오;박태조
    • Tribology and Lubricants
    • /
    • v.10 no.3
    • /
    • pp.47-53
    • /
    • 1994
  • Thin film flow in the clearance between cylinder bore and axially moving compositeshape piston is analyzed to study the effect of piston shape on the lubrication characteristics of hydraulic piston pump and motor. It is shown that the piston shape significantly affect the distribution of fluid film pressure, lateral force acting on the piston and leakage flow rate in the clearance. And it is also shown that the composite-shape piston is more effective than the cylindrical piston under tilted condition to reduce the possibility of hydraulic locking. Therefore, the results of present study can be used usefully in the design-and manufacturing of hydraulic piston pump and motor.

Influence of Bradykinin on the tubular function of the dog kidney (신세뇨관기능(腎細尿管機能)에 미치는 Bradykinin의 영향(影響))

  • Sub, Byoung-Chul
    • The Korean Journal of Pharmacology
    • /
    • v.2 no.1 s.2
    • /
    • pp.5-12
    • /
    • 1966
  • In this study the influence of Bradykinin, a biogenic polypeptide, on the excretory function of the dog kidney was investigated, utilizing the clearance and stop-flow method. The results are summarized as follows; 1) Bradykinin administered intravenously elicited a marked antidiuresis. 2) When given into the renal artery, however, prompt increase of the urine flow, sodium excretion and free water clearance without significant change in the glomerular filtration rate ensued. 3) It was also effective during an osmotic diuresis with 10% Mannitol infusion, though the response was not so marked. 4) The stop-flow experiment showed that sodium reabsorption in the proximal tubules is inhibited by the infusion of bradykinin into the renal artery. It was thus concluded that the diuretic effect of bradykinin given intra-arterially results from the inhibition of sodium transport in the proximal tubules.

  • PDF

Development of an Intake E-CVVT Noise for the Medium-sized Sedan Vehicle (중형 세단 차량의 흡기 전동 CVVT 소음 개발)

  • Lee, Jong Kyu;Lee, Hyung Min;Lee, Hae Seung;Kwon, O Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.341-346
    • /
    • 2014
  • Intake E-CVVT noise, generally caused by collision sound of roller and cage clearance at idle and driving condition, is considerable source of annoyance in passenger cars using the gasoline engine. Main source of this noise is the cam torque variation of an intake E-CVVT system, and can be controlled by clearance decrease such as backlash reduction, but which may increase the manufacturing cost. Thus in this paper, most effective solution for low noise intake E-CVVT was achieved through not only reduction of backlash and cam angular acceleration but also improvement of vehicle transfer system, which is optimal configuration through acoustic sensitivity optimization of engine mount support bracket.

  • PDF

Flow-induced instability and nonlinear dynamics of a tube array considering the effect of a clearance gap

  • Lai, Jiang;Sun, Lei;Li, Pengzhou
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1650-1657
    • /
    • 2019
  • Fluidelastic instability and nonlinear dynamics of tube bundles is a key issue in a steam generator. Especially, once the post-instability motion of the tube becomes larger than the clearance gap to other tubes, effective contact or impact between the tubes under consideration and the other tube inevitable. There is seldom theoretical analysis to the nonlinear dynamic characteristics of a tube array in two-phase flow. In this paper, experimental and numerical studies were utilized to obtain the critical velocity of the flow-induced instability of a rotated triangular tube array. The calculation results agreed well with the experimental data. To explore the post-instability dynamics of the tube array system, a Runge-Kutta scheme was used to solve the nonlinear governing equations of tube motion. The numerical results indicated that, when the flow pitch velocity is larger than the critical velocity, the tube array system is undergoing a limit cycle motion, and the dynamic characteristics of the tube array are almost similar for different void fractions.

A Study on the Clearance Level(draft) for the Steel Scrap from the KRR-1 & 2 Decommissioning (연구로 1,2호기 해체 철재폐기물의 규제해제농도기준(안) 도출을 위한 연구)

  • 홍상범;이봉재;정운수
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.60-67
    • /
    • 2004
  • The exposure dose form recycling of a large amount of the steel scrap from the KRR-1&2 decommissioning activities was evaluated, and also the clearance level(draft) was derived. The maximum individual dose and collective dose were evaluated by modifying internal dose conversion factor which was based on the concept of effective dose in ICRP 60, applied to the RESRAD-RECYCLE ver 3.06 computing code, IAEA Safety Series 111-P-1.1 and NUREG-1640 as the assessment tool. The result of assessment for individual dose and collective dose is 23.9 $\mu$Sv per year and 0.11 man$.$Sv per year respectively. The clearance levels were ultimately determined by extracting the most conservative value form the results of the generic assessment and specific assessment methodologies. The result of clearance level for radionuclides( $Co^{60}$ , C $s^{l37}$) is less than 1.14${\times}$10$^{-1}$ Bq/g to comply with the clearance criterion(maximum individual dose : 10 $\mu$Sv per year, collective dose : 1 man$.$Sv per year) provided for Korea Atomic Energy Act and relevant regulations.s.

  • PDF

Herbal Medicine for Cervical Intraepithelial Neoplasia After Loop Electrosurgical Excision Procedure: A Systematic Review and Meta-Analysis (자궁경부 상피내종양의 환상투열요법 후 한약치료의 효과 : 체계적 문헌고찰 및 메타분석)

  • Lee, Su-Jeong;Ji, Hae-Ri;Lee, Hye-Jung;Hwang, Deok-Sang;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.33 no.2
    • /
    • pp.44-62
    • /
    • 2020
  • Objectives: The purpose of this study is to evaluate the effectiveness of herbal medicine for recovery and treatment of cervical intraepithelial neoplasia (CIN) after loop electrosurgical excision procedure (LEEP). Methods: We searched two english, one chinese and four korean database up to November 4, 2019. Randomised controlled trials (RCTs) were eligible. Primary outcome included Human papilloma virus (HPV) clearance rate and the effective ratio of treatment. And vaginal bleeding time and volume, improvement of symptoms, and recovery of wound were regarded as secondary outcomes. The risk of bias was assessed by two independent authors using the Cochrane risk of bias tool. Results: Of 47 screened, 10 RCTs were included. Number of participants per study ranged from 58 to 360. The studies which used HPV clearance rate as primary outcome were considered as low risk of bias. Most of the studies had considerable heterogeneity in terms of type of intervention, comparison and time-points for outcome measurement. Compared to LEEP alone, herbal vaginal suppository combined group showed favorable results for HPV clearance in patients (5 studies, n=627, 95% CI 1.26 to 1.55, I2=75%). And compared to LEEP alone, herbal external application also showed favorable results for HPV clearance in patients (2 studies, n=252, 95% CI 1.19 to 1.61, I2=86%). Three studies reported mild and temporary adverse events, and no serious adverse events were reported. Conclusions: The studies showed that herbal medicine can significantly effective on recovery of CIN after LEEP. However, included studies suffered from incomplete reporting, high or unclear risk of bias and substantial heterogeneity between studies. In the Future, further high-quality RCTs are needed to prove effectiveness of herbal medicine for CIN after LEEP and reduce the risk of bias.

Effects of Dietary Rna and Adenine on Feed Intake and Kidney Weight and Function in Adult Cockerels

  • Kubota, T.;Karasawa, Yutaka
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.10 no.3
    • /
    • pp.260-264
    • /
    • 1997
  • This study was conducted with adult cockerels to determine whether dietary RNA affects feed intake and renal weight and function, and if the responses are similar to dietary adenine. Chickens were ad libitum fed a RNA diet (100 g/kg) or an adenine diet (9.1 g/kg) for 14 d and catheterized in right jugular vein, hepatic portal vein and both urethers, and saline together with para-amino hippuric acid and sodium thiosulfate was continuously infused into them to evaluate renal functions. Dietary RNA reduced feed intake and body weight, and dietary adenine increased kidney weight expressed as a proportion of body weight (P < 0.05). Feed intake and body weight on the adenine diet and kidney weight on the RNA diet showed similar though non significant tendencies. No calculi were detected in the kidney in chickens fed either the RNA or adenine diets. Plasma inorganic phosphate (IP), Ca and 1,25 $(OH)_2$ vitamin $D_3$ concentrations were increased by dietary RNA and adenine, although the increases of IP and Ca in adenine-fed chickens were not significant. Uric acid and urea concentrations in the blood plasma were unaffected by dietary RNA or adenine. Both dietary RNA and adenine increased renal blood flow rates 3.5-3.7 fold, renal plasma flow rates 3.4-3.7 fold and glomerular filtration rates (GFR) 2.9-3.0 fold (p < 0.01). Clearance of urea, IP and Ca were also enhanced by dietary RNA, but not by dietary adenine. However, neither RNA nor adenine affected uric acid clearance. Only IP clearance was significantly augmented at the glomerular level by dietary RNA (p < 0.05). Glomerular filtration of uric acid, urea, IP and Ca and reabsorption of urea, IP and Ca at the renal tubule were increased by dietary RNA and adenine (p < 0.05), whereas tubular secretion of uric acid was decreased by both dietary treatments. It is concluded that dietary adenine is effective in changing renal function and P and Ca metabolism in chickens.

A Theoretical Study on the Boiling Heat Transfer Performance of Tubes with Extended Surfaces (확대 전열관의 비등열전달에 관한 이론적 연구)

  • Jho, S.G.
    • Solar Energy
    • /
    • v.19 no.2
    • /
    • pp.45-56
    • /
    • 1999
  • The performance of vertical and horizontal tubes with extended surface of rectangular and triangular cross section was investigated theoretically for boiling heat transfer. A simple method for numerical program assuming one-dimensional heat flow was used to predict the performance of these extended surface tubes. The object of this study was to predict the effects of the height, thickness, numbers and, clearance of the extended surface on boiling heat transfer. The results showed that extended surfaces are quite effective as compared to plane surfaces especially near the bum-out point and to promote heat flux in boiling heat transfer.

  • PDF