• Title/Summary/Keyword: edge region

Search Result 1,160, Processing Time 0.035 seconds

Suggestions for Using Historical and Cultural Resources in Uiseong : Focusing on the Gilt-bronze Crown and the Earthenware of Jomunguk (의성 지역 역사문화자원 활용을 위한 제안 : 조문국 금동관과 토기를 중심으로)

  • Lee, Eunjoo;Kim, Migyung;Kim, Youngsun
    • 지역과문화
    • /
    • v.6 no.3
    • /
    • pp.79-105
    • /
    • 2019
  • In the Geumseongsan Tumulus of the Uiseong area where the Jomunguk was existed in the Three Han Period, many relics such as metal craft ornaments and Uiseong-style earthernware were excavated. However, it is hard to find cases where the excavated relics were used to develop cultural products. In this study, symbolic relics which can express the culture of Uiseong Jomunguk were selected from excavated relics. Then, the basic design that can be applied to various cultural products were derived from symbolic relics. In order to select symbolic relics, the formative characteristics of the metal craft relics excavated from the Tablili Tumulus and the Dali Tumulus were examined. As a result, a gilt-bronze crown excavated from the Tablili Tumulus was selected as a symbolic relics. And then the basic desin was derived from the gilt-bronze crown. The basic design is expressed in the form of birds based on the bird's feather shape at the edge of the standing ornaments and the record of the Bongdae(鳳臺), the phoenix's habitat. And the application design that changed the expression of the birds' face was presented. The earthenware excavated from the Uiseong area was designed as a soil pot and applied various indoor air purification plants. The result of this study, which reinterprets and reconstructs the historical and cultural resources of the region in accordance with the modern sense, can be used as useful data for the development of cultural products of Jomunguk. Furthermore, if the design derived from the Jomunguk relics is used as a representative symbol of the area, it will be possible to derive an image of a differentiated region from other regions. Finally, it is expected that the result of this study will be a chance to re-evaluate the value of the historical and cultural resources in the region.

The Evaluation of the Difference of the SUV Caused by DFOV Change in PET/CT (PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.13-20
    • /
    • 2011
  • Purpose: The limited FOV(Field of View) of CT (Computed Tomography) can cause truncation artifact at external DFOV (Display Field of View) in PET/CT image. In our study, we measured the difference of SUV and compared the influence affecting to the image reconstructed with the extended DFOV. Materials and Methods: NEMA 1994 PET Phantom was filled with $^{18}F$(FDG) of 5.3 kBq/mL and placed at the center of FOV. Phantom images were acquired through emission scan. Shift the phantom's location to the external edge of DFOV and images were acquired with same method. All of acquired data through each experiment were reconstructed with same method, DFOV was applied 50 cm and 70 cm respectively. Then ROI was set up on the emission image, performed the comparative analysis SUV. In the clinical test, patient group shown truncation artifact was selected. ROI was set up at the liver of patient's image and performed the comparative analysis SUV according to the change of DFOV. Results: The pixel size was increase from 3.91 mm to 5.47 mm according to the DFOV increment in the centered location phantom study. When extended DFOV was applied, $_{max}SUV$ of ROI was decreased from 1.49 to 1.35. In case of shifted the center of phantom location study, $_{max}SUV$ was decreased from 1.30 to 1.20. The $_{max}SUV$ was 1.51 at the truncated region in the extended DFOV. The difference of the $_{max}SUV$ was 25.9% higher at the outside of the truncated region than inside. When the extended DFOV was applied, $_{max}SUV$ was decreased from 3.38 to 3.13. Conclusion: When the extended DFOV was applied, $_{max}SUV$ decreasing phenomenon can cause pixel to pixel noise by increasing of pixel size. In this reason, $_{max}SUV$ was underestimated. Therefore, We should consider the underestimation of quantitative result in the whole image plane in case of patient study applied extended DFOV protocol. Consequently, the result of the quantitative analysis may show more higher than inside at the truncated region.

  • PDF

A STATISTICAL ANALYSIS OF SOLAR WIND DYNAMIC PRESSURE PULSES DURING GEOMAGNETIC STORMS (지자기폭풍 기간 동안의 태양풍 동압력 펄스에 관한 통계적 분석)

  • Baek, J.H.;Lee, D.Y.;Kim, K.C.;Choi, C.R.;Moon, Y.J.;Cho, K.S.;Park, Y.D.
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.4
    • /
    • pp.419-430
    • /
    • 2005
  • We have carried out a statistical analysis on solar wind dynamic pressure pulses during geomagnetic storms. The Dst index was used to identify 111 geomagnetic storms that occurred in the time interval from 1997 through 2001. We have selected only the events having the minimum Dst value less than -50 nT. In order to identify the pressure impact precisely, we have used the horizontal component data of the magnetic field H (northward) at low latitudes as well as the solar wind pressure data themselves. Our analysis leads to the following results: (1) The enhancement of H due to a pressure pulse tends to be proportional to the magnitude of minimum Dst value; (2) The occurrence frequency of pressure pulses also increases with storm intensity. (3) For about $30\%$ of our storms, the occurrence frequency of pressure pulses is greater than $0.4\#/hr$, implying that to. those storms the pressure pulses occur more frequently than do periodic substorms with an average substorm duration of 2.5 hrs. In order to understand the origin of these pressure pulses, we have first examined responsible storm drivers. It turns out that $65\%$ of the studied storms we driven by coronal mass ejections (CMEs) while others are associated with corotating interaction regions $(6.3\%)$ or Type II bursts $(7.2\%)$. Out of the storms that are driven by CMEs, over $70\%$ show that the main phase interval overlaps with the sheath, namely, the region between CME body and the shock, and with the leading region of a CME. This suggests that the origin of the frequent pressure pulses is often due to density fluctuations in the sheath region and the leading edge of the CME body.

Type Classification and Material Properties by the Composition of Components in Gold Earrings Excavated from the Yeongnam Region (영남지역 출토 금제 귀걸이의 성분 조성에 따른 유형 분류와 금속 재료 특성)

  • Jeon, Ikhwan;Kang, Jungmoo;Lee, Jaesung
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.1
    • /
    • pp.4-21
    • /
    • 2019
  • In this paper, 23 Silla gold earrings from the sixth and seventhand centuries, excavated from the Yeongnam region, were analyzed. Based on the silver content of the gold plate, they were classified into three types. The classifications included type I(20-50wt%), type II(10-20wt%) and type III (less than 10wt%). In the analysis process, the composition and morphological differences were identified on the surface of the gold plate. In the case of type I and II earrings, it was observed that the fine holes were concentrated in a relatively higher part of the gold content. The causes of the difference in the surface composition of the gold plate were divided into four categories: 1) surface treatment, 2) thermal diffusivity in the manufacturing process, 3) differences in composition of alluvial gold, and 4) the refining method of gold. It is possible that depletion gilding was attempted to increase the gold content while intentionally removing the other metals from the surface of the gold alloy in the portion where the gold deposit is relatively concentrated on the surface of the gold plating. The highest copper content was detected in the earring with the highest gold content of the analyzed earrings, and it was assumed that thermal diffusion had occurred between the gold plate and the metal rod during the manufacturing process rather than intentional addition. Copper was detected only in the thin ring earring type, and copper was not detected in the thick ring earring type or pendant type. It also proves that this earring has a high degree of tightness at higher temperatures, as there was an invisible edge finish on other earrings and horizontal wrinkles on the gold plate surface. In terms of the material of the gold plate, we examined whether the silver content of the gold plate was natural gold or added by alloy through analyzing the alluvial gold collected in the region. As a result of the analysis, it was found that on average about 13wt% of silver is included. This suggests that type II is natural gold, type III is refined gold, and type I seems to have been alloyed with natural gold. Here, we investigated the refining method introduced in the ancient literature, both at home and abroad, about the possibility of alloying silver after the refining process of type III earrings and then making pure gold. It was found that from ancient refining methods, silver which had been present in the natural gold was removed by reacting and combining with silver chloride or silver sulfide, and long-term efforts and techniques were required to obtain pure gold through this method. Therefore, it was concluded that the possibility of adding a small amount of silver in order to increase strength after making pure gold through a refining process is low.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

The Analysis of Quantitative EEG to the Left Cranial Cervical Ganglion Block in Beagle Dogs (비글견에서 좌측앞쪽목신경절 차단에 대한 정량적 뇌파 분석)

  • Park, Woo-Dae;Bae, Chun-Sik;Kim, Se-Eun;Lee, Soo-Han;Lee, Jung-Sun;Chang, Wha-Seok;Chung, Dai-Jung;Lee, Jae-Hoon;Kim, Hwi-Yool
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.514-521
    • /
    • 2007
  • The sympathetic nerve block improves the blood flow in the innervated regions. For this region, the sympathetic nerve block has been performed in the neural and cerebral disorders. However, the cerebral blood flow regulation of the cranial cervical ganglion block in dogs have not been well defined and the correlation to the changes in the cerebral circulation and the changes in the electroencephalogram is not well defined in dogs yet. Therefore, we investigated the hypothesis that changes in the EEG could be affected by the changes in cerebral blood flow following the cranial cervical ganglion block in dogs. Twenty five beagle dogs were divided into 3 groups; group I(LCCGB, n=10) underwent left sided cranial cervical ganglion block using the 1% lidocaine, group II(L, n=10) injected the 1% lidocaine into the right or left sided digastricus muscle, group III(N/SCCGB, n=5, served as control) underwent the left sided cranial cervical ganglion block using saline. A statistical difference was not found between the control group and the LCCGB group in the 95% spectral edge frequency(SEF) and the median frequency(MF). In the relative band power, the $\delta$ frequency was decreased during 5-25 min, while the $\alpha$ frequency was increased during the same time(p<0.05). But the $\theta$ frequency and the $\beta$ frequency were not shown the significant changes compared with the control group during the same time(p<0.05). These results suggest that the left cranial cervical ganglion block does not induce the change of the cerebral blood flow and its effect is insignificant.

Research of Diffusion Bonding of Tungsten/Copper and Their Properties under High Heat Flux

  • Li, Jun;Yang, Jianfeng
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.14-14
    • /
    • 2011
  • W (tungsten)-alloys will be the most promising plasma facing armor materials in highly loaded plasma interactive components of the next step fusion reactors due to its high melting point, high sputtering resistance and low deuterium/tritium retention. The bonding technology of tungsten to Cu alloy was one of the key issues. In this paper, W/CuCrZr diffusion bonding has been performed successfully by inserting pure metal interlay. The joint microstructure, interfacial elements migration and phase composition were analyzed by SEM, EDS, XRD, and the joint shear strength and micro-hardness were investigated. The mock-ups were fabricated successfully with diffusion bonding and the cladding technology respectively, and the high heat flux test and thermal fatigue test were carried out under actively cooling condition. When Ni foil was used for the bonding of tungsten to CuCrZr, two reaction layers, Ni4W and Ni(W) layer, appeared between the tungsten and Ni interlayer with the optimized condition. Even though Ni4W is hard and brittle, and the strength of the joint was oppositely increased (217 MPa) due primarily to extremely small thicknesses (2~3 ${\mu}m$). When Ti foil was selected as the interlayer, the Ti foil diffused quickly with Cu and was transformed into liquid phase at $1,000^{\circ}C$. Almost all of the liquid was extruded out of the interface zone under bonding pressure, and an extremely thin residual layer (1~2 ${\mu}m$) of the liquid phase was retained between the tungsten and CuCrZr, which shear strength exceeded 160 MPa. When Ni/Ti/Ni multiple interlayers were used for bonding of tungsten to CuCrZr, a large number of intermetallic compound ($Ni_4W/NiTi_2/NiTi/Ni_3T$) were formed for the interdiffusion among W, Ni and Ti. Therefore, the shear strength of the joint was low and just about 85 MPa. The residual stresses in the clad samples with flat, arc, rectangle and trapezoid interface were estimated by Finite Element Analysis. The simulation results show that the flat clad sample was subjected maximum residual stress at the edge of the interface, which could be cracked at the edge and propagated along the interface. As for the rectangle and trapezoid interface, the residual stresses of the interface were lower than that of the flat interface, and the interface of the arc clad sample have lowest residual stress and all of the residual stress with arc interface were divided into different grooved zones, so the probabilities of cracking and propagation were lower than other interfaces. The residual stresses of the mock-ups under high heat flux of 10 $MW/m^2$ were estimated by Finite Element Analysis. The tungsten of the flat interfaces was subjected to tensile stresses (positive $S_x$), and the CuCrZr was subjected to compressive stresses (negative $S_x$). If the interface have a little microcrack, the tungsten of joint was more liable to propagate than the CuCrZr due to the brittle of the tungsten. However, when the flat interface was substituted by arc interfaces, the periodical residual stresses in the joining region were either released or formed a stress field prohibiting the growth or nucleation of the interfacial cracks. Thermal fatigue tests were performed on the mock-ups of flat and arc interface under the heat flux of 10 $MW/m^2$ with the cooling water velocity of 10 m/s. After thermal cycle experiments, a large number of microcracks appeared at the tungsten substrate due to large radial tensile stress on the flat mock-up. The defects would largely affect the heat transfer capability and the structure reliability of the mock-up. As for the arc mock-up, even though some microcracks were found at the interface of the regions, all microcracks with arc interface were divided into different arc-grooved zones, so the propagation of microcracks is difficult.

  • PDF

Development of Video Image-Guided Setup (VIGS) System for Tomotherapy: Preliminary Study (단층치료용 비디오 영상기반 셋업 장치의 개발: 예비연구)

  • Kim, Jin Sung;Ju, Sang Gyu;Hong, Chae Seon;Jeong, Jaewon;Son, Kihong;Shin, Jung Suk;Shin, Eunheak;Ahn, Sung Hwan;Han, Youngyih;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.85-91
    • /
    • 2013
  • At present, megavoltage computed tomography (MVCT) is the only method used to correct the position of tomotherapy patients. MVCT produces extra radiation, in addition to the radiation used for treatment, and repositioning also takes up much of the total treatment time. To address these issues, we suggest the use of a video image-guided setup (VIGS) system for correcting the position of tomotherapy patients. We developed an in-house program to correct the exact position of patients using two orthogonal images obtained from two video cameras installed at $90^{\circ}$ and fastened inside the tomotherapy gantry. The system is programmed to make automatic registration possible with the use of edge detection of the user-defined region of interest (ROI). A head-and-neck patient is then simulated using a humanoid phantom. After taking the computed tomography (CT) image, tomotherapy planning is performed. To mimic a clinical treatment course, we used an immobilization device to position the phantom on the tomotherapy couch and, using MVCT, corrected its position to match the one captured when the treatment was planned. Video images of the corrected position were used as reference images for the VIGS system. First, the position was repeatedly corrected 10 times using MVCT, and based on the saved reference video image, the patient position was then corrected 10 times using the VIGS method. Thereafter, the results of the two correction methods were compared. The results demonstrated that patient positioning using a video-imaging method ($41.7{\pm}11.2$ seconds) significantly reduces the overall time of the MVCT method ($420{\pm}6$ seconds) (p<0.05). However, there was no meaningful difference in accuracy between the two methods (x=0.11 mm, y=0.27 mm, z=0.58 mm, p>0.05). Because VIGS provides a more accurate result and reduces the required time, compared with the MVCT method, it is expected to manage the overall tomotherapy treatment process more efficiently.

Implementation of a Self Controlled Mobile Robot with Intelligence to Recognize Obstacles (장애물 인식 지능을 갖춘 자율 이동로봇의 구현)

  • 류한성;최중경
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.5
    • /
    • pp.312-321
    • /
    • 2003
  • In this paper, we implement robot which are ability to recognize obstacles and moving automatically to destination. we present two results in this paper; hardware implementation of image processing board and software implementation of visual feedback algorithm for a self-controlled robot. In the first part, the mobile robot depends on commands from a control board which is doing image processing part. We have studied the self controlled mobile robot system equipped with a CCD camera for a long time. This robot system consists of a image processing board implemented with DSPs, a stepping motor, a CCD camera. We will propose an algorithm in which commands are delivered for the robot to move in the planned path. The distance that the robot is supposed to move is calculated on the basis of the absolute coordinate and the coordinate of the target spot. And the image signal acquired by the CCD camera mounted on the robot is captured at every sampling time in order for the robot to automatically avoid the obstacle and finally to reach the destination. The image processing board consists of DSP (TMS320VC33), ADV611, SAA7111, ADV7l76A, CPLD(EPM7256ATC144), and SRAM memories. In the second part, the visual feedback control has two types of vision algorithms: obstacle avoidance and path planning. The first algorithm is cell, part of the image divided by blob analysis. We will do image preprocessing to improve the input image. This image preprocessing consists of filtering, edge detection, NOR converting, and threshold-ing. This major image processing includes labeling, segmentation, and pixel density calculation. In the second algorithm, after an image frame went through preprocessing (edge detection, converting, thresholding), the histogram is measured vertically (the y-axis direction). Then, the binary histogram of the image shows waveforms with only black and white variations. Here we use the fact that since obstacles appear as sectional diagrams as if they were walls, there is no variation in the histogram. The intensities of the line histogram are measured as vertically at intervals of 20 pixels. So, we can find uniform and nonuniform regions of the waveforms and define the period of uniform waveforms as an obstacle region. We can see that the algorithm is very useful for the robot to move avoiding obstacles.

Sensitivity Analysis for CAS500-4 Atmospheric Correction Using Simulated Images and Suggestion of the Use of Geostationary Satellite-based Atmospheric Parameters (모의영상을 이용한 농림위성 대기보정의 주요 파라미터 민감도 분석 및 타위성 산출물 활용 가능성 제시)

  • Kang, Yoojin;Cho, Dongjin;Han, Daehyeon;Im, Jungho;Lim, Joongbin;Oh, Kum-hui;Kwon, Eonhye
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.1029-1042
    • /
    • 2021
  • As part of the next-generation Compact Advanced Satellite 500 (CAS500) project, CAS500-4 is scheduled to be launched in 2025 focusing on the remote sensing of agriculture and forestry. To obtain quantitative information on vegetation from satellite images, it is necessary to acquire surface reflectance through atmospheric correction. Thus, it is essential to develop an atmospheric correction method suitable for CAS500-4. Since the absorption and scattering characteristics in the atmosphere vary depending on the wavelength, it is needed to analyze the sensitivity of atmospheric correction parameters such as aerosol optical depth (AOD) and water vapor (WV) considering the wavelengths of CAS500-4. In addition, as CAS500-4 has only five channels (blue, green, red, red edge, and near-infrared), making it difficult to directly calculate key parameters for atmospheric correction, external parameter data should be used. Therefore, thisstudy performed a sensitivity analysis of the key parameters (AOD, WV, and O3) using the simulated images based on Sentinel-2 satellite data, which has similar wavelength specifications to CAS500-4, and examined the possibility of using the products of GEO-KOMPSAT-2A (GK2A) as atmospheric parameters. The sensitivity analysisshowed that AOD wasthe most important parameter with greater sensitivity in visible channels than in the near-infrared region. In particular, since AOD change of 20% causes about a 100% error rate in the blue channel surface reflectance in forests, a highly reliable AOD is needed to obtain accurate surface reflectance. The atmospherically corrected surface reflectance based on the GK2A AOD and WV was compared with the Sentinel-2 L2A reflectance data through the separability index of the known land cover pixels. The result showed that two corrected surface reflectance had similar Seperability index (SI) values, the atmospheric corrected surface reflectance based on the GK2A AOD showed higher SI than the Sentinel-2 L2A reflectance data in short-wavelength channels. Thus, it is judged that the parameters provided by GK2A can be fully utilized for atmospheric correction of the CAS500-4. The research findings will provide a basis for atmospheric correction of the CAS500-4 in the future.