• Title/Summary/Keyword: edge pressure

Search Result 679, Processing Time 0.028 seconds

B-mode ultrasound images of the carotid artery wall: correlation of ultrasound with histological measurements

  • Gamble G.;Beaumont B.;Smith H.;Zorn J.;Sanders G.;Merrilees M.;MacMahon S.;Sharpe N.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02b
    • /
    • pp.169-179
    • /
    • 1994
  • B-mode ultrasound is being used to assess carotid atherosclerosis in epidemiological studies and clinical trials. Recently the interpretation of measurements made from ultrasound images has been questioned. This study examines the anatomical correlates of B-mode ultrasound of carotid arteries in vitro and in situ in cadavers. Twenty-seven segments of human carotid artery were collected at autopsy. pressure perfusion fixed in buffered 2.5% gluteraldehyde and 4% paraformaldehyde and imaged using an ATL UM-8 (10 MHz single crystal mechanical probe). Each artery was then frozen, sectioned and stained with van Gieson or elastin van Gieson. The thickness of the intima. media and adventitia were measured 'to an accuracy of 0.01 mm from histological sections using a calibrated eye graticule on a light microscope. Shrinkage artifact induced by histological preparation was determined to be 7.8%. Digitised ultra sound images of the artery wall were analysed off-line. The distance from the leading edge of the first interface ($LE_{1}$) to the leading edge of the second interface ($LE_2$) was measured using a dedicated programme. $LE_{1}$-$LE_{2}$ measurements were correlated against histological measurements corrected for shrinkage. Mean values for the far wall were: ultra sound $LE_{1}$-$LE_{2}$ (0.97 mm, S.D. 0.26), total wall thickness (1.05 mm, S.D. 0.37), adventitia (0.35 mm, S.D. 0.16), media (0.61 mm, S.D. 0.18). intima (0.09 mm, S.D. 0.13). Ultrasound measurements corresponded best with total wall thickness, rather than elastin or the intima-media complex. Excision of part of the intima plus media or removal of the adventitia resulted in a corresponding decrease in the $LE_{1}$-$LE_{2}$ distance of the B-mode image. Furthermore. increased wall thickness due to intimal atherosclerotic thickening correlated well with $LE_{1}$-$LE_{2}$ distance of the B-mode images. B-mode images obtained from the carotid arteries in situ in four cadavers also corresponded best with total wall thickness measured from histological sections and not with the thickness of the intima plus media. In conclusion, the $LE_{1}$-$LE_{2}$ distance measured on B-mode images of the carotid artery best represents total wall thickness of intima plus media plus adventitia and not intima plus media alone.

  • PDF

Local Variation of Magnetic Parameters of the Free Layer in TMR Junctions

  • Kim, Cheol-Gi;Shoyama, Toshihiro;Tsunoda, Masakiyo;Takahashil, Migaku;Lee, Tae-Hyo;Kim, Chong-Oh
    • Journal of Magnetics
    • /
    • v.7 no.3
    • /
    • pp.72-79
    • /
    • 2002
  • Local M-H loops have been measured on the free layer of a tunneling magnetoresistance (TMR) junction using the magneto-optical Kerr effect (MOKE) system, with an optical beam size of about 2 $\mu$m diameter. Tunnel junctions were deposited using the DC magnetron sputtering method in a chamber with a base pressure of 3$\times$10$^{-9}$ Torr. The relatively irregular variations of coercive force H$_c$(∼17.5 Oe) and unidirectional anisotropy field H$_{ua}$(∼7.5 Oe) in the as-deposited sample are revealed. After $200{^{\circ}C}$ annealing, He decreases to 15 Oe but H$_{ua}$ increases to 20 Oe with smooth local variations. Two-dimensional plots of H$_c$ and H$_{ua}$ show the symmetric saddle shapes with their axes aligned with the pinned layer, irrespective of the annealing field angle. This is thought to be caused by geometric effects during deposition, together with a minor annealing effect. In addition, the variation of root mean square (RMS) surface roughness reveals it to be symmetric with respect to the center of the pinned-layer axis, with the roughness of 2.5 $\AA$ near the edge and 5.8 $\AA$ at the junction center. Comparison of surface roughness with the variation of H$_{ua}$ suggests that the H$_{ua}$ variation of the free layer is well described by dipole interactions related to surface roughness. As a whole, the reversal magnetization is not uniform over the entire junction area and the macroscopic properties are governed by the average sum of local distributions.

Variation Characteristics of the Groundwater Level of Natural Vegetation and Sandy Beaches (식생/모래기반 자연해빈에서의 지하수위 변동특성)

  • Park, JungHyun;Yoon, Han-sam
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.1
    • /
    • pp.62-73
    • /
    • 2016
  • The variation of groundwater by wave, tide and precipitation conditions is closely related to the vegetation environment at the natural vegetation and sandy based beach, and it has a significant impact on the vegetation development and ground stabilization. In this study, the water temperature, electrical conductivity, and pressure were monitored at five observational stations normal to the Jinu-do(Island) shoreline of Nakdong river estuary from March 2012 to September 2014 (approximately 799 days) with the aim of measuring the variation in groundwater-table characteristics. The purpose of the study was to identify factors (tide, wave etc.) affecting groundwater-table variation using time series and correlation analysis, and to record spatial variations in the groundwater level and electrical conductivity as a result of storm events. The observational station in the intertidal zone was strongly affected by wave period and tide level. During the storm period, the groundwater-table and electrical conductivity were stabilized at the edge of sand dunes, vegetation, and areas of transition between freshwater and seawater.

Development of the Vision System to Inspect the Inside of the Brake Calipers (브레이크 캘리퍼 내부 검사를 위한 비전시스템 개발)

  • Kwon, Gyoung Hoon;Chu, Hyung Gon;Kim, Jin Young;Kang, Joonhee
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.39-43
    • /
    • 2017
  • Development of vision system as a nondestructive evaluation system can be very useful in screening the defective mechanical parts before they are assembled into the final product. Since the tens of thousands of the mechanical parts are used in an automobile carefully inspecting the quality of the mechanical parts is very important to maximize the performance of the automobile. To sort out the defective mechanical parts before they are assembled, auto parts fabrication companies employ various inspection systems. Nondestructive evaluation systems are getting rapidly popular among various inspection systems. In this study, we have developed a vision system to inspect the inside of the brake caliper, a part that is used to compose a brake which is the most important to the safety of the drivers and the passengers. In a brake caliper, a piston is pushed against the brake disk by oil pressure, causing a friction to damp the rotation of the wheel. Inside the caliper, a groove is positioned to adopt an oil seal to prevent the oil leaks. Inspecting the groove with our vision system, we could examine the existence of the contaminants which are normally the residual tiny pieces from the machining process. We used a high resolution GigE camera, 360 degree lens to look in the inside view of the caliper at once, and a special illumination system in this vision system. We used the edge detection technique to successfully detect the contaminants which were in the form of small metal chips. Labview graphical program was used to process the digital data from the camera and to display the vision and the statistics of the contaminants. We were very successful in detecting the contaminants from the various size calipers. We think we are ready to employ this vision system to the caliper production factories.

Evaluation of Wear of Periodontal Curet's Lateral Surface in Working-end (수종 치주큐렛의 작업측 마모도의 비교연구)

  • Shin, Dong-Whan;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.703-715
    • /
    • 1999
  • The purpose of this study was to evaluate the degree of wear of periodontal curet's cutting edges made by three different manufacturers. In the first case of the experiment, this study was done with each new curett in the following three experiment. Twelve new double-ended No. 11/12 Gracy curettes from three different manufacturers (A, B and C) was randomly selected from our stock at first test. They were weared by wear tester with fixed pressure and limited distance. This study measured the width of worn curettes'cutting edge. The results were as follows ; 1)In 50 times experiment, this study discoverd that each manufacturer's curette was appeared with different degree of wear (p<0.01) 2)In 100 times experiment, this study result similarly to the 50 times experiment(p<0.01). 3)In 150 times experiment, the result of this study were alike as the X50 experiment and X100 experiment. In the second case of the experiment, the study was done with a curett of a manufacturer in the following three experiment. Two double-ended No. 11/12 Gracy curette from three different manufactures (A, B and C) was randomly selected from our stock at second test. 1)In 50 times experiment, this study discovered that each manufacturer's curette was appeared with different degree of wear (p<0.05). 2)In 100 times experiment, the result was same, compared with the 50 times experiment. 3)In 150 times experiment, this study also discovered that the result was same with the result of the upper two cases. In conclusion, this study discovered that the two cases of experimental were shown with a same result.

  • PDF

A Numerical Study on a Circulation Control Foil using Coanda Effect (코앤다 효과를 이용한 순환 제어 날개의 수치적 연구)

  • J.J. Park;S.H. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.2
    • /
    • pp.70-76
    • /
    • 2000
  • A numerical study on the viscous flow around a 2-dimensional circulation control foil is carried out for application on the field of naval architecture and ocean engineering. The governing equations are the RANS and the continuity equations. The equations are discretized by finite difference method and MAC method and the pressure poisson equation is calculate by a SOR method and an O-type non-staggered boundary fitted coordinate system which is overlapped near the slot is used to improve the numerical accuracy. Turbulence is approximated by a modified Baldwin-Lomax turbulence model. In the present paper, the Coanda effect on a 2-dimensional foil of a 20% thickness ellipse with modified rounded trailing edge has been numerically studied. The change in drag and lift of the foil with various jet momentums are calculated and compared to the experimental results to show good agreements.

  • PDF

A Potential-Based Panel Method for the Analysis of a 2-Dimensional Partially Cavitating Hydrofoil (양력판 이론에 의한 2차원 수중익의 부분 캐비티 문제 해석)

  • Chang-Sup,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.26 no.4
    • /
    • pp.27-34
    • /
    • 1989
  • A potential-based panel method is formulated for the analysis of a partially cavitating 2-dimensional hydrofoil. The method employs dipoles and sources distributed on the foil surface to represent the lifting and cavity problems, respectively. The kinematic boundry condition on the wetted portion of the foil surface is satisfied by requiring that the total potential vanish in the inner flow region of the foil. The dynamic boundary condition on the cavity surface is satisfied by requiring that the potential vary linearly, i.e., the velocity be constant. Green's theorem then results in a potential-based boundary value problem rather than a usual velocity-based formulation. With the singularities distributed on the exact hydrofoil surface, the pressure distributions are predicted with more improved accuracy than the zero-thickness hydrofoil theory, especially near the leading edge. The theory then predicts the cavity shape and cavitation number for an assumed cavity length. To improve the accuracy, the sources and dipoles on the cavity surface are moved to the newly computed cavity surface, where the boundary conditions are satisfied again. It was found that five iterations are necessary to obtain converged values, while only two iterations are sufficient for engineering purpose.

  • PDF

Effects of Combustor-Level High Inlet Turbulence on the Endwall Flow and Heat/Mass Transfer of a High-Turning Turbine Rotor Cascade

  • Lee, Sang-Woo;Jun, Sang-Bae;Park, Byung-Kyu;Lee, Joon-Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.8
    • /
    • pp.1435-1450
    • /
    • 2004
  • Experimental data are presented which describe the effects of a combustor-level high free-stream turbulence on the near-wall flow structure and heat/mass transfer on the endwall of a linear high-turning turbine rotor cascade. The end wall flow structure is visualized by employing the partial- and total-coverage oil-film technique, and heat/mass transfer rate is measured by the naphthalene sublimation method. A turbulence generator is designed to provide a highly-turbulent flow which has free-stream turbulence intensity and integral length scale of 14.7% and 80mm, respectively, at the cascade entrance. The surface flow visualizations show that the high free-stream turbulence has little effect on the attachment line, but alters the separation line noticeably. Under high free-stream turbulence, the incoming near-wall flow upstream of the adjacent separation lines collides more obliquely with the suction surface. A weaker lift-up force arising from this more oblique collision results in the narrower suction-side corner vortex area in the high turbulence case. The high free-stream turbulence enhances the heat/mass transfer in the central area of the turbine passage, but only a slight augmentation is found in the end wall regions adjacent to the leading and trailing edges. Therefore, the high free-stream turbulence makes the end wall heat load more uniform. It is also observed that the heat/mass transfers along the locus of the pressure-side leg of the leading-edge horseshoe vortex and along the suction-side corner are influenced most strongly by the high free-stream turbulence. In this study, the end wall surface is classified into seven different regions based on the local heat/mass transfer distribution, and the effects of the high free-stream turbulence on the local heat/mass transfer in each region are discussed in detail.

A Study on Flow Induced Vibration of Cantilever Plate with Angle of Attack (받음각을 갖는 평판보의 유동 여기진동에 관한 연구)

  • 이기백;손창민;김봉환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.1919-1932
    • /
    • 1991
  • Experimental studies are conducted to investigate the Flow-Induced Vibration mechanism for cantilever plate model with the angle of attack (.alpha.=10.deg., 20.deg., 30.deg.). Research is divided into two parts. First, the flow fields around two dimensional flat plate model are investigated using LDV system. Second, the vortex shedding frequency and response spectra of cantilever plate are obtained experimentally using gap sensor and hot wire anemometer. Finite element method program was used in order to predict the flow field and pressure field around thin flat plate. And some predicted results were compared with the experimental data. The aspect ration of test model is d/t=25 (d; width, t; thickness). From the measurement of the flow field it was found that in the case of small inclined (.alpha.=10.deg., 20.deg.) relatively, the separated boundary layer at sharp leading edge developed smoothly downstream. With increasing the angle of attack of the plate, stagnation region was appeared on the back side of the plate and separated boundary layer was extended downstream. These trends are a good agreement with the computational results. It was found by analysis of response spectra of cantilever plate that the influences of vortex shedding frequency were important at the large of attack (.alpha.=30.deg.), and two peak values appear in entire test model at 24Hz, 150Hz.

Relative Absorption Edges of GaN/InGaN/GaN Single Quantum Wells and InGaN/GaN Heterostructures by Metalorganic Chemical Vapor Deposition (유기금속화학기상증착법으로 성장된 GaN/InGaN/GaN 단양자 우물층과 InGaN/GaN 이종접합 구조의 광학적 특징)

  • Kim, Je-Won;Son, Chang-Sik;Jang, Yeong-Geun;Choe, In-Hun;Park, Yeong-Gyun;Kim, Yong-Tae;Ambacher, O.;Ctutzmann, M.
    • Korean Journal of Materials Research
    • /
    • v.9 no.1
    • /
    • pp.42-45
    • /
    • 1999
  • The room temperature optical transmission spectra of GaN /InGaN/GaN single quantum wells (SQW) and InGaN/GaN heterostructures grwon by low pressure metalorganic chemical vapor deposition have been measured. The dependence of the absorption edges of the GaN/InGaN/GaN SQW on the well width has been determined from the transmission spectra. The result shows that the absorption edge of GaN/InGaN/GaN SQW shifts towards lower energy as increasing the well width. The dependence of the absorption edges of the InGaN/GaN heterostructures on InN mole fraction has also been determined from the transmission spectra. The result is compared with calculated values obtained from Vegards's laws. Our result shows a good agreement with the calculated values.

  • PDF