• Title/Summary/Keyword: economic efficiency evaluation

Search Result 408, Processing Time 0.026 seconds

Performance Evaluation of the Capillary Tube Radiant Floor Cooling & Heating System (모세유관 바닥복사 냉·난방 시스템의 성능평가)

  • Seo, Yu-jin;Kim, Taeyeon;Leigh, Seung-bok
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.89-95
    • /
    • 2012
  • At present, many countries are trying to reduce green gas emissions to mitigate the effects of these gases on climate change. Year after year, there have been efforts to cut energy use for heating and cooling. Heating and cooling systems, common in all forms of housing, are increasing due to the constant supply of new housing resulting from improvements in economic growth and the quality of life. Thus, studies related to the design of cooling and heating systems to improve energy efficiency are expanding. Among the new designs, radiant floor cooling and heating systems which use capillary tubes are becoming viable means of reducing energy use. Radiant floor cooling and heating systems which use capillary tubes are creative and sustainable systems in which cool and hot water is circulated into capillary tube which has small diameter. In this study, the cooling and heating performance of this type of capillary tube system is investigated in an experimental study and a simulation using TRNSYS. The results of the experimental study show that under a peak load, a capillary tube radiant floor cooling system using geothermal energy can achieve desired indoor temperature without an additional heat source. The set room air temperature is maintained while the floor surface temperature, PMV and PPD remain within the comfort range. Also, this system is more economic than a packaged air conditioner system due to its higher COP. The results of the simulation show that the capillary tube radiant floor heating system maintains set temperature more stable than a PB pipe radiant floor heating system due to its lower supply temperature of hot water. In terms of energy consumption, the capillary tube radiant floor heating system is more efficient than the PB pipe radiant floor heating system.

Evaluation of Durability Characteristics of High Performance Shotcrete Using Fly Ash (폐석탄회를 이용한 고성능 숏크리트의 내구특성 평가)

  • Park, Cheol-Woo;Lee, Hyeon-Gi;Kang, Tae-Sung
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.305-311
    • /
    • 2010
  • The industrial by-product market has increased at a geometric rate worldwide with the rapid economic growth. At present time, conventional disposal methods of industrial by-products in Korea including landfill, incineration and storage already have reached their limits. In this study, the industrial by-products such as fly ash and silicafume were used as mineral admixtures, which are commonly added to concrete mix to inhance the economic efficiency, long-term strength and durability of concrete, to determine the optimized mix proportion of high performance shotcrete. Through the series of tests (compressive strength test, accelerated chloride ion penetration test, measurement of chloride diffusion coefficient). The results of the study showed that the proposed mix proportions satisfied the requirements of domestic as well as international guidelines for shotcrete, with a higher durability than the existing shotcrete.

The Function of Health Center in the New Public Health Age (공중보건의 역할변화와 보건소의 기능)

  • 배상수
    • Health Policy and Management
    • /
    • v.11 no.1
    • /
    • pp.131-152
    • /
    • 2001
  • Public health system and public health practice have changed over the past decades as the result of social and epidemiologic changes. New public health concept emphasizes leadership, strategical thinking, systematic planning and effective performance to identify and solve complex health problem In Korea, the role of Health Center has been expanded rapidly. However there is strong suspicion that Health Center can achieve their mission. This paper aims at understanding what is the needed functions of Health Center and which of its aspects needs improvement. The main results of this study are summarizes as follows. District Health Law does not address the core functions of Health Center. The staffs of Health Center have difficulties in prioritizing their services. The recent attempt to restructure Health Center and change delivery pattern of public health services ended with only limited success. To effectively confront threats to the public's health, the three major function of Health Center must be ${\circled}1$ modifying individual behavior and lifestyle, ${\circled}2$ improving social and economic conditions, and ${\circled}3$ reforming health policies. Better results do not come from setting new functions only; they come from understanding and improving the processes that will then leads to better outcome. We recommend that policy-makers focus economic evaluation of public health programs, building and spreading of the scientific evidence of programs, linkage of public health research and public health program. The criteria of delegation of public health service to private sector is urgently needed. Making community health information data available on a routine basis to providers, managers and researchers of public health services helps promote the efficiency of the overall operation of public health system.

  • PDF

Economic Valuation of the Taehwa Field Ecological Park: An Application of a Contingent Valuation Method with Preferance Uncertainly (태화들 생태공원의 경제적 가치추정에 관한 연구: 선호불확실성을 고려한 조건부가치측정법의 적용)

  • Kim, Jae-Hong
    • Journal of Environmental Policy
    • /
    • v.9 no.1
    • /
    • pp.109-135
    • /
    • 2010
  • This study estimated the social benefits of establishment 01 the Taehwa Field Ecology Park in Ulsan Metropolitan City, using CVM(Contingent Valuation Method) with multiple choices in consideration of respondent's uncertainty. The estimation results 01 lour logit models show that the probability of willingness-to-pay increases significantly with higher income, higher evaluation on the relevancy of establishment of the Park, and male gender, and decreases significantly with the bidding price. Truncated mean household WTP is estimated as 2,409.4 KRW in the MBYES model with the most efficient estimates of WTP among four models. On the basis of the WTP estimates, the present values of total social benefits in Ulsan Metropolitan City are estimated as 236.5 bill ion KRW when applying the 5% discount rate. This result shows that the present values of total social benefits are greater than the total costs in all models, and thus may prove the economic relevancy of the investment for the ecology park establishment.

  • PDF

Three-Dimensional Information Extraction of Discontinuity on Rock Slope by Processing Stereo Digital Images (입체 디지털 영상처리에 의한 암반사면의 불연속면에 대한 3차원 정보 추출)

  • Lee Dong-Cheon;Woo Ik;Choi Jin Ok
    • Economic and Environmental Geology
    • /
    • v.38 no.4 s.173
    • /
    • pp.369-380
    • /
    • 2005
  • This study describes image-based approach for efficient and objective evaluation method of the rock slope stability. Three-dimensional rock slope model was reconstructed by processing stereo digital images. The model provided fundamental information for geospatial analysis of the rock slope. Methods to extract three-dimensional information about discontinuity on the rock slope and to estimate roughness of the rock surfaces were suggested. The results show that stereo digital images have potential to provide information for both quantitative and qualitative analysis of rock slope. In addition, visualization of the results increases efficiency and benefit in evaluating rock slope stability.

Economic Evaluation of Glass Greenhouse Heating Solar Thermal System Applied with Seasonal Borehole Thermal Energy Storage System (BTES 방식의 계간축열 시스템을 적용한 유리온실의 난방용 태양열시스템의 경제성 평가)

  • Park, Sang-Mi;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.63-74
    • /
    • 2018
  • The heating performance of a solar thermal seasonal storage system applied to a 1,320 m2 glass greenhouse was analyzed numerically, and the economic feasibility depending upon the number of boreholes was evaluated. For this study, the gardening 16th and 19th zucchini greenhouse of Jeollanam-do agricultural research & extension services was selected. And the heating load of the glass greenhouse selected was 1,147 GJ. BTES(Borehole Thermal Energy Storage) was considered as a seasonal storage, which is relatively economical. The number of boreholes was selected from 25 to 150. The TRNSYS was used to predict and analyze the dynamic performance of the solar thermal system. Numerical simulation was performed by modelling the solar thermal seasonal storage system consisting of flat plate solar collector, BTES system, short-term storage tank, boiler, heat exchanger, pump and controller. As a result of the analysis, when the number of boreholes was from 25 to 50, the thermal efficiency of BTES system and the solar fraction was the highest. When the number of boreholes was from 25 to 50, it was analyzed that the payback period was from 5.2 years to 6.2 years. Therefore it was judged to be the number of boreholes of the proposed system was from 25 to 50, which is the most efficient and economical.

Modeling of Precast Concrete Shear Walls BIM Program (BIM 프로그램을 이용한 프리캐스트 콘크리트 전단벽의 모델링)

  • Mun, Ju-Hyun;Yoon, Hyun-Sub;Kim, Jong-Won;Eom, Byung-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.5
    • /
    • pp.451-462
    • /
    • 2022
  • The objective of the study is to establish a BIM modeling of precast concrete(PC) shear wall with various wall-to-base connections. The family library of PC shear wall was established in BIM program using component function in a IFC(Industry foundation classes) file format and SketchUp program. From the BIM program, the amounts of concrete, reinforcing bars and steel materials as well as the interference of arranged reinforcing bars can be accurately evaluated in the PC shear walls with spliced sleeves, bolt, or welding plate connection methods. Although the additional metallic materials such as steel plates, bolts, and nuts were used in the PC shear walls with welding plate connection method, their amounts of materials, economic efficiency, and environmental impact were similar to those with spliced sleeve connection. Consequently, the bolt or welding connection is a highly applicable method as wall-to-base connection of PC shear walls, and it was a more useful method than spliced sleeve method, particularly considering the constructability.

A Study on Safe Operation Standards of Piers based on Mooring Safety Evaluation to Increase Efficiency of Local Management Trade Ports (지방관리 무역항의 효율성 증대를 위한 계류안전성 평가 기반의 부두 안전운용기준에 관한 연구)

  • Kim, Seungyeon;Yu, Yongung;Lee, Yunsok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.1
    • /
    • pp.107-116
    • /
    • 2022
  • Local management trade ports are small-sized trade ports, which require active operation to strengthen the local cities' economic power and enhance the local industries' added value. In addition, local management trade ports should berth ships larger than the existing ships to increase efficiency and keep up with the international trend where ships are becoming larger. Furthermore, they should also prepare operating standards. This study selected Okgye Port among local management trade ports. We performed a mooring safety simulation evaluation according to the scenario where a 50,000 DWT vessel is moored at the current 20,000 DWT class pier. The emergency departure criteria were 27kts at 3.2s of wave period and 22kts at 5.0s of wave period at the existing pier. Results showed that mooring limit condition increased by about 50% to 41kts at 3.2s of wave period and 36kts at 5.0s of wave period. This study can be used for strengthening mooring facilities and setting operational standards for safe port operation when large ships are berthing.

Evaluation and Application of Retention Aids for Papermaking System Closure

  • Lee, Hak-Lae;Sung, Yong-Joo;Youn, Hye-Jung;Kim, Yong-Sik;Oh, Jong-Ik
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.30 no.4
    • /
    • pp.11-17
    • /
    • 1998
  • Reducing the effluent discharge from a paper mill is urgently needed due to tightening environmental regulations and economic reasons. For a paper mill to respond to system closure it is required to adopt the best practical retention system that enables the mill to improve fines retention and drainage. In this study, effects of various retention agents on fines retention, drainage and formation were examined using linerboard stock in the laboratory. Among the retention aids tested, high molecular weight cationic polyacrylamides showed good efficiency both in retention and drainage. On the other hand, high charge density, low molecular weight polymeric retention aids showed little improvement both in retention and drainage. The best retention system selected from the laboratory experiment was applied on a paper machine producing linerboard to evaluate its effect on papermaking system closure.

  • PDF

Analysis of Energy Consumption of Buildings in the University (대학교 건축물의 에너지소비 특성 및 변화 추이 분석:서울소재 A대학교의 에너지 소비 실태를 중심으로)

  • Park, Kang-Hyun;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.9
    • /
    • pp.633-638
    • /
    • 2011
  • Increasing demand for comfortable indoor environment and air-conditioning demand is also increasing. Building energy consumption in university which is made up of many different kinds factor was researched. Central control air-conditioning systems are being replaced with individually controlled air-conditioning system. The amount of growth of electricity consumption is due to the increasing demand of EHP. Conversely, the demand for absorption chiller-heater is shrinking. Winter and in summer a lot of electricity and gas usage. On the other hand, showed less energy in spring and autumn. Increase the amount of electricity than the degree of decline in gas consumption was higher. Can be considered as transitional phenomena. Because EHP and the absorption chiller-heater are used at the same time in some of the buildings. To use energy efficiently is needed additional research about environmental impact, economic evaluation.