• Title/Summary/Keyword: echo time

Search Result 454, Processing Time 0.024 seconds

A Study on Noise Characteristic of Multi-channel Seismic Data for the Hydrothermal Deposit Survey at Lau Basin, South Pacific (열수광상 탐사를 위한 남태평양 라우분지 다중채널 탄성파 자료의 잡음특성 연구)

  • Ok, Soo-Jong;Ha, Young-Soo;Lee, Jin-Woo;Shin, Sung-Ryul
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.235-235
    • /
    • 2011
  • Lau basin of south Pacific, as an active back arc basin, is promising area bearing seafloor massive hydrothermal deposit that is located in a subduction zone between the Pacific ocean plate and Indo-Australian continental plate. Korea Ocean Research and Development Institute tracked from 2004 to 2006 the hydrothermal activity to the extension of the northeast Lau Basin, targeting seamount. hydrothermal activity by tracking was found hydrothermal evidences. In this study, Marine seismic survey was carried out in the Lau basin seamount of the possibility of hydrothermal deposit. In particular, Marine magnetic survey and seismic survey was carried out at the same time in TA-12 seamount and noise characteristics were found in the seamount. the main process of data processing is Bandpass filter, FK filter, Deconvolution for noise attenuation such backscatter and multiple reflections. the migration is performed to compensate for reflection points followed by seamount of a slope. In this study, bedrock and upper strata could be identified and in the Future, the comparative method with Multi Beam Echo Sounder(MBES) are likely to derive the correct velocity model, the marine magnetic survey results should be considered.

  • PDF

Implementation about measurement of the head SAR and variable parameter according to operation control mode in brain MR study with 1.5Tesia (1.57 BRAIN MRI검사에서의 작동제어모드를 통한 두부 SAR측정과 변화인자에 관한 고찰)

  • Lee, Kyu-Su;Sim, Hyun;Moon, Ji-Hoon;Oh, Jae-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.58-60
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has become a very widely used medical procedur e. Clo.sed and open systems are typically used with static magnetic fields at or below 2 Tesla. BWhole body SAR(specific absorbsion rate) is the value of SAR averaged over the entire body of the patient over any period of 15 minutes. Head SAR is the value of SAR averaged over the head of the patient for any period of 10 minutes. SAR is a measure of the absorption of electromagnetic energy in the body' (typically in watts per kilogram (W/kg)). The normal operating mode comprises values of head SAR not higher than 3 W/kg. The second level controlled operating mode comprises values higher than 3 W/kg. Current FDA guidance limits the SAR in the whole body. including the head to a range of 1.5 to 4.0 W/kg, depending on the patient's clinical condition. SAR, limit restrictions are incorporated in all MRI systems. and domestic' s guidance limits the SAR in a part body. including the head to 3.2w/kg and less. The purpose of this study is to evaluate on change of head SAR in using MRI pulse sequence and to check if exceed 3.2(w/kg) level in domestic a part exposure through measured head SAR. 23 patient's the average head SAR of pulse sequence is that T2WI sagittal is 0.5375. T2WI axial(FSE) is 0.4817, T1WI axial(SE) is, 0.8179. FLAIR axial is 0.4580. GRE axial is 0.0077, Diffusion is 0.0824w/kg. The head SAR exposed per patient was proved 2.3845w/kg less than the international standard. Coefficient of correlation for the relations body weight and SAR or for the relations ETL(echo train length) and SAR is 1 value. Coefficient of correlation for the relations between TR(time to repeat) and SAR is -0.602 value. so SAR increased relative to weight body and ETL. But the relations between TR and SAR is negative definite.

  • PDF

Development of Smart Phone Application for the Safe Operation of Inland Vessels (내수면 선박의 안전운항을 위한 스마트폰기반 어플리케이션 개발)

  • Jo, Byung-Wan;Lee, Yun-Sung;Kim, Do-Keun;Kim, Jung-Hoon;Kim, Kil-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.4
    • /
    • pp.442-454
    • /
    • 2016
  • Recently, due to the increment of national income and the living standard of citizens, the leasure business has been dramatically expanded. Among the business, inland water activities such as cruise tour or water taxi have drawn attention from the people. As more people come for a new pleasure, the frequency and the number of services continues to rise yet the safety of people values less recently. In fact, the number of relating accidents also has risen accordingly. In order to prevent such accidents in inland waters, the vessels' real time voyage data, the advanced warning system and the emergency rescuing system are required. In this paper, we have developed navigation guiding application for safety of passengers and vessels in inland waters. Navigation guiding applications not only provide Inland Electronic Navigational Chart(IENC) and vessel information but also allows communication between traffic service center and nearby vessels in case of an emergency situation. In order to implement Navigation guiding applications, developing Inland Electronic Navigational Chart was inevitable. Therefore, IENC of Han River, has developed based on measuring the water depth using multi-beam echo sounder system.

Development of PC Based Signal Postprocessing System in MR Spectroscopy: Normal Brain Spectrum in 1.5T MR Spectroscopy (PC를 이용한 자기공명분광 신호처리분석 시스템 개발: 1.5T MR Spectroscopy에서의 정상인 뇌 분광 신호)

  • 백문영;강원석;이현용;신운재;은충기
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.128-135
    • /
    • 2000
  • Purpose : The aim of this study is to develope the Magnetic Resonance Spectroscopy(MRS) data processing S/W which plays an important role as a diagnostic tool in clinical field. Materials and methods : Post-processing software of MRS based on graphical user interface(GUI) under windows operating system of personal computer(PC) was developed using MATLAB(Mathwork, U.S.A.). This tool contains many functions to increase the quality of spectrum data such as DC correction, zero filling, line broadening, Gauss-Lorentzian filtering, phase correction, etc. And we obtained the normal human brain $^1H$ MRS data from parietal white matter, basal ganglia and occipital grey matter region using 1.5T Gyroscan ACS-NT R6 (philips, Amsterdam, Netherland) MRS package. The analysis of the MRS peaks were performed by obtaining the ratio of peak area. Results : The peak ratios of NAA/Cr, Cho/Cr, MI/Cr for the different MRS machines have a little different values. But these peak ratios were not significantly different between different echo time MRS peak ratios in the same machine (p<0.05). Conclusion : MRS post-processing S/W based on GUI using PC was developed and applied to the analysis of normal human brain $^1H$ MRS. This independent MRS processing job increases the performance and throughput of patient scan of main console. Finally, we suggest that the database for normal in-yivo human MRS data should be obtained before clinical applications.

  • PDF

Acoustic Target Strength of the Pelagic Fish in the Southern Waters of Korea I. In situ Measurement of Target Strength of Anchovy (Engraulis japonica) (한국 남해안 부어류의 음향반사강도에 관한 연구 I. 멸치 (Engraulis japonica)의 in situ 반사강도 측정)

  • YOON Gab Dong;KIM Zang Geun;CHOI Young Min
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.1
    • /
    • pp.107-114
    • /
    • 1996
  • The in situ target strength for the anchovy (Engraulis japonica) were measured by the split beam echo sounder system at 38 kHz. This study allowed us to detect the single echos from anchovy shoals which were dispersed during trawling operation in day time. The results of our study were as fellows: We found that the anchouy occupied about $95\%$ of the total catch from the detected shoals from which target strength data were collected. Length distribution of anchovy showed a mode and ranged from 13.6 to 15.4cm with a mean of 14.4cm and a standard deviation of 0.45cm, and weight distribution showed a mode and ranged from 16 to 28 g witha mean of 21.9 g and a standard deviation of 2.7 g. The target strength distribution of anchovy ranged from -40.7 dB to -69.2 dB in the water layer of ,$10\~30\;m$ -42.19 to -67.7 dB in the $30\~50\;m$ and -42.2 to -67.7 dB in $10\~50\;m$, showing 2 modes in each layer, respectively. Overall mean target strengths were -49.7 dB/fish and -33.1 dB/kg, averaged by area backscattering cross section $(\sigma)$, and the confidence interval for target strength was less than 1 dB. With the mean total length and the mean target strength, we drived the target strength-length relationship as $TS(\sigma)=20\;Log\;L-72.9$.

  • PDF

A Study on the Diel Distribution and Activity Patterns of Fishes in the Korean Eastern Sea (한국 동해 어족생물의 일주기적 유영행동특성에 관한 연구)

  • 이대재;김성기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.85-94
    • /
    • 2001
  • The vertical distribution and activity patterns of fishes during the evening and morning transitions were investigated acoustically and by pelagic trawling on October 2-10, 1997 in the Korean Eastern Sea. The acoustic data were collected from four stations with a scientific echo sounder operating at a frequency of 38 kHz, and the echogram was used to analyze the diel vertical migration of fish. Biological sampling was accomplished by pelagic trawling to identify fish species recorded on the echograms, and the species and length compositions were investigated. Vertical profiles of water temperature, salinity at the trawl station were taken with a CTD system and were related to the diel movement and the depth distribution of fish. During the day, one group of fish mainly distributed above the depth layer of 50 m, the other group was at deeper water, approximately 250 m, but began to migrate toward the surface before sunset with a time difference. During the night, they were dispersed between the surface and the depth of 125 m. Just prior to sunrise, the scattering layer was divided with 2 groups and began to migrate downwards, respectively. Several trials of pelagic trawling for scattering layers suggest that the most dominant scatterer in the survey area of this study was Japanese flying squid, Todarodes pacificus..

  • PDF

Implementation of Multi-Core Processor for Beamforming Algorithm of Mobile Ultrasound Image Signals (모바일 초음파 영상신호의 빔포밍 알고리즘을 위한 멀티코어 프로세서 구현)

  • Choi, Byong-Kook;Kim, Jong-Myon
    • The KIPS Transactions:PartA
    • /
    • v.18A no.2
    • /
    • pp.45-52
    • /
    • 2011
  • In the past, a patient went to the room where an ultrasound image diagnosis device was set, and then he or she was examined by a doctor. However, currently a doctor can go and examine the patient with a handheld ultrasound device who stays in a room. However, it was implemented with only fundamental functions, and can not meet the high performance required by the focusing algorithm of ultrasound beam which determines the quality of ultrasound image. In addition, low energy consumption was satisfied for the mobile ultrasound device. To satisfy these requirements, this paper proposes a high-performance and low-power single instruction, multiple data (SIMD) based multi-core processor that supports a representative beamforming algorithm out of several focusing methods of mobile ultrasound image signals. The proposed SIMD multi-core processor, which consists of 16 processing elements (PEs), satisfies the high-performance required by the beamforming algorithm by exploiting considerable data-level parallelism inherent in the echo image data of ultrasound. Experimental results showed that the proposed multi-core processor outperforms a commercial high-performance processor, TI DSP C6416, in terms of execution time (15.8 times better), energy efficiency (6.9 times better), and area efficiency (10 times better).

Calculation of Optical Flow Vector Based on Weather Radar Images Using a Image Processing Technique (영상처리기법을 활용한 기상레이더 영상기반 광학흐름 벡터 산출에 관한 연구)

  • Mo, Sunjin;Gu, Ji-Young;Ryu, Geun-Hyeok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.67-69
    • /
    • 2021
  • Weather radar images can be used in a variety of ways because of their high visibility in terms of visuals. In other words it has the advantage of being able to grasp the flow of weather phenomena using not only the raw data of the weather radar, but also the change characteristics between consecutive images. In particular image processing techniques are gradually expanding in the field of meteorological research, and in the case of image data having high resolution such as weather radar images it is expected to produce useful information through a new approach called image processing techniques. In this study the weather phenomena flow was calculated as a vector from the change of the weather radar image according to time interval with the optical flow method, one of the image processing techniques. The characteristics of the weather phenomena to be analyzed were derived through vector analysis resolution suitable for the scale of weather, vector interpolation in regions where no radar echo exists, and the removal of relative flow vectors to distinguish the flow of specific weather and the entire atmosphere. Through this study, it is expected that not only the use of raw data of weather radar, but also the widening of the application area of weather radar, such as the use of unique characteristics of image data, and the active use of image processing techniques in the field of meteorology in the future.

  • PDF

Evaluation of Antidepressant Drug Effect in a Depressive Animal Model by Proton MR Spectroscopy (양성자 자기공명분광법을 이용한 우울증 동물모델에서의 항우울제 약물 효능 평가)

  • Kim, Sang-Young;Choi, Chi-Bong;Lee, Sung-Ho;Woo, Dong-Cheol;Yoon, Seong-Ik;Hong, Kwan-Soo;Lee, Hyun-Sung;Cheong, Chae-Joon;Jee, Bo-Keun;Hong, Sung-Tak;Kim, Hwi-Yool;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.95-101
    • /
    • 2008
  • In this study, we observed the alteration of choline signal intensity in hippocampus region of the depressive rat model induced by forced swimming test (FST). The purpose of this study was to evaluate the antidepressant efficacy in the depressive animal model using MR spectroscopy. Fourteen experimentally naive male Sprague-Dawley rats weighting $160{\sim}180\;g$ were used as subjects. Drug injection group was exposed to the FST except for control group. The drugs were administered subcutaneously (SC) in a volume equivalent to 2ml/kg. And three injections were administered 23, 5, and 1h before beginning the given test. 1H MR spectra were obtained with use of a point resolved spectroscopy (PRESS) localization sequence performed according to the following parameters: repetition time, 2500 ms; echo time, 144 ms; 512 average; 2048 complex data points; voxel dimensions, $1.5{\times}2.5{\times}2.5\;mm^3$ ; acquisition time, 25min. There were no differences in NAA/Cr and Cho/Cr ratio between the right and the left hippocampus both normal control rats and antidepressant-injected rats. Also, no differences were observed in NAA/Cr and Cho/Cr ratio between the normal control rats and the antidepressant-injected rats both the right and the left hippocampus. In this study, we found the recovery of choline signals in the depressive animal model similar to normal control groups as injecting desipramine-HCl which was antidepressant causing anti-immobility effects. Thus, we demonstrated that MR spectroscopy was able to aid in evaluating the antidepressant effect of desipramine-HCl.

  • PDF

Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method (Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법)

  • Han, Yong-Hee;Kim, Tae-Hyung;Chun, Song-I;Kim, Dong-Hyeuk;Lee, Kwang-Sig;Eun, Choong-Ki;Jun, Jae-Ryang;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • Purpose : This study proposes the keyhole method in order to improve the time resolution of the proton resonance frequency(PRF) MR temperature monitoring technique. The values of Root Mean Square (RMS) error of measured temperature value and Signal-to-Noise Ratio(SNR) obtained from the keyhole and full phase encoded temperature images were compared. Materials and Methods : The PRF method combined with GRE sequence was used to get MR temperature images using a clinical 1.5T MR scanner. It was conducted on the tissue-mimic 2% agarose gel phantom and swine's hock tissue. A MR compatible coaxial slot antenna driven by microwave power generator at 2.45GHz was used to heat the object in the magnetic bore for 5 minutes followed by a sequential acquisition of MR raw data during 10 minutes of cooling period. The acquired raw data were transferred to PC after then the keyhole images were reconstructed by taking the central part of K-space data with 128, 64, 32 and 16 phase encoding lines while the remaining peripheral parts were taken from the 1st reference raw data. The RMS errors were compared with the 256 full encoded self-reference temperature image while the SNR values were compared with the zero filling images. Results : As phase encoding number at the center part on the keyhole temperature images decreased to 128, 64, 32 and 16, the RMS errors of the measured temperature increased to 0.538, 0.712, 0.768 and 0.845$^{\circ}C$, meanwhile SNR values were maintained as the phase encoding number of keyhole part is reduced. Conclusion : This study shows that the keyhole technique is successfully applied to temperature monitoring procedure to increases the temporal resolution by standardizing the matrix size, thus maintained the SNR values. In future, it is expected to implement the MR real time thermal imaging using keyhole method which is able to reduce the scan time with minimal thermal variations.

  • PDF