• Title/Summary/Keyword: echo reduction

Search Result 65, Processing Time 0.019 seconds

Application of Very Short-Term Rainfall Forecasting to Urban Water Simulation using TREC Method (TREC기법을 이용한 초단기 레이더 강우예측의 도시유출 모의 적용)

  • Kim, Jong Pil;Yoon, Sun Kwon;Kim, Gwangseob;Moon, Young Il
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.5
    • /
    • pp.409-423
    • /
    • 2015
  • In this study the very short-term rainfall forecasting and storm water forecasting using the weather radar data were implemented in an urban stream basin. As forecasting time increasing, the very short-term rainfall forecasting results show that the correlation coefficient was decreased and the root mean square error was increased and then the forecasting model accuracy was decreased. However, as a result of the correlation coefficient up to 60-minute forecasting time is maintained 0.5 or higher was obtained. As a result of storm water forecasting in an urban area, the reduction in peak flow and outflow volume with increasing forecasting time occurs, the peak time was analyzed that relatively matched. In the application of storm water forecasting by radar rainfall forecast, the errors has occurred that we determined some of the external factors. In the future, we believed to be necessary to perform that the continuous algorithm improvement such as simulation of rapid generation and disappearance phenomenon by precipitation echo, the improvement of extreme rainfall forecasting in urban areas, and the rainfall-runoff model parameter optimizations. The results of this study, not only urban stream basin, but also we obtained the observed data, and expand the real-time flood alarm system over the ungaged basins. In addition, it is possible to take advantage of development of as multi-sensor based very short-term rainfall forecasting technology.

Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array (선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가)

  • Lee, D.H.;Hong, C.P.;Han, B.S.;Kim, H.J.;Suh, J.J.;Kim, S.H.;Lee, C.H.;Lee, M.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

Vital Sign Detection in a Noisy Environment by Undesirable Micro-Motion (원하지 않는 작은 동작에 의한 잡음 환경 내 생체신호 탐지 기법)

  • Choi, In-Oh;Kim, Min;Choi, Jea-Ho;Park, Jeong-Ki;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.5
    • /
    • pp.418-426
    • /
    • 2019
  • Recently, many studies on vital sign detection using a radar sensor related to Internet of Things(IoT) smart home systems have been conducted. Because vital signs such as respiration and cardiac rates generally cause micro-motions in the chest or back, the phase of the received echo signal from a target fluctuates according to the micro-motion. Therefore, vital signs are usually detected via spectral analysis of the phase. However, the probability of false alarms in cardiac rate detection increases as a result of various problems in the measurement environment, such as very weak phase fluctuations caused by the cardiac rate. Therefore, this study analyzes the difficulties of vital sign detection and proposes an efficient vital sign detection algorithm consisting of four main stages: 1) phase decomposition, 2) phase differentiation and filtering, 3) vital sign detection, and 4) reduction of the probability of false alarm. Experimental results using impulse-radio ultra-wideband radar show that the proposed algorithm is very efficient in terms of computation and accuracy.

Final Report of China-Korea Collaborative Project of Control Strategies of Clonorchiasis in Heilongjiang Pilot Areas(2001-2004) (중국 흑룡강성 간흡충증 관리사업(2001-2004))

  • Ji, Zhuo;Li, Zhimin;Wang, Shuyu;Yuan, Ren;Ge, Tao;Yuan, Shang;Cui, Changyuan;Ge, Hongan;Feng, Zheng;Xu, Longqi;Hong, Sung-Tae;Choi, Min-Ho;Cho, Seung-Yull;Choi, Dong-Il;Hong, Kwang-Seon;Rim, Han-Jong;Lee, Soon-Hyung
    • Journal of Korea Association of Health Promotion
    • /
    • v.3 no.1
    • /
    • pp.72-83
    • /
    • 2005
  • The present pilot project was executed to recommend a strategy of clonorchiasis control in China. The pilot area of this project was Zhaoyuan, Hailin, and Ningan, Heiloagjiang province. A baseline survey subjecting 4,865 residents in Heilongjiang confirmed Zhaoyuan asa high endemic area and Hailin and Ningan as moderate endemic areas. Six different control strategies were implemented in Zhaoyuan, two were in Hailin, and one was in Ningan. Including the baseline survey and project programs from 2000 to 2004, total 63,274subject-times were examined of their feces for Clonorchiseggs, 26,680 were treated, 10,082 were screened by ELISA, and 6,130 subjects were examined of their liver by sonography. The egg Positive rates in 6 villages of Zhaoyuan were as high as 44.8% 70,0%. Following the protocolof each strategy, the subjected residents were examined of their feces and treated with 25 mg/kg praziquantel, 3 times. Except the control group, all of the villages showed 72.8% to 92.0% reduction of their original egg Positive rates at Zhaoyuan. Mass treatments of all subjected residents in 2001 and 2003 reduced the egg rate from 68.8% to18.7% and 4 annual mass treatments reduced the rate from 44.8% in 2001 to 8.7% in 2004.Selective annual treatments of egg positive subjects reduced the egg rates from 50.8% in2001 to 13.8% in 2004 or from 70.0% in 2001 to 11.6% in 2004, and two treatments in a year reduced the rate from 57.6% in 2001 to 4.6% in 2004. According to repeated treatments, EPG counts decreased remarkably. In moderate endemic areas, the original egg rates were 22.6% and 28.3% in 2001 but were 1.7% and 1.1% after 2 or 3 selective treatments. The present findings of the chemotherapeutic control of clonorchiasis prove that repeated medication is important. The reduction is directly correlated with dose of praziquantel but not with mass or selective treatments. Chemotherapeutic control of reservoirhosts has little effect on reinfection of clonorchiasis because the field along the Songhua-jiang is too wide to be impacted. ELISA confirmed many serologically positive cases to Clonorchisantigen but only a few cases were positive to other antigens (Paragonimus, cysticercus, sparganum). The abdominal soaography visualized intrahepatic bile duct dilatation and periductal echo in 2,002 of 6,070 examined subjects. In addition to these examinations and treatment, health education supplemented tㅗe control activities. The present findings prove clonorchiasis is very widely prevalent and heavily endemic along the rivers in Heiloagjiang. The results suggest that group chemotherapy with praziquantel is effective to reduce endemicity of clonorchiasis. Mass treatment without individual fecal examination is recommended in heavy endemic areas where the egg rate is over 40% while one selective treatment is effective enough in moderate endemic areas.

  • PDF

Recent updated diagnostic methods for esophageal motility disorders (식도의 운동장애에 관한 최신지견)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.11-16
    • /
    • 2004
  • Classification of esophageal motility disorders not yet finalized and is still ongoing as the new disorders are reported, and the existing classification is changed or removed. In terms of radiology, the primary peristalsis does not exist, and the lower end of the esophagus show the smooth, tapered, beak-like appearance. The esophageal motility disorder, which mostly occurs in the smooth muscle area, show the symptoms of reduction or loss (hypomotility) or abnormal increase (hypermotility) of peristalsis of the esophagus. It is important to understand the anatomy and physiology of the esophagus for the appropriate radiological method and diagnosis. Furthermore, the symptom of the patient and the manometry finding must be closely referred for the radiological diagnosis. The lower esophageal sphincter can be normally functioning and open completely as the food moves lower. Sperandio M et al. argues that the name diffuse esophageal spasm must be changed to distal esophageal spasm (DES) as most of the spasm occurs in the distal esophagus, composed of the smooth muscle. According to Ott et al., usefulness of barium method for diagnosing the esophageal motility disorder is Achalasia 95%, DES 71% and NEMD 46%, with the overall sensitivity of 56%. However, excluding the nutcracker esophagus or nonspecific disorder which cannot be diagnosed with the radiological methods, the sensitivity increases to 89%. Using videofluoroscopy and 5 time swallows, the average sensitivity was over 90%. In conclusion, the barium method is a simple primary testing method for esophageal motility test. Using not only the image but also the videofluoroscopy with good knowledge of the anatomy and physiology, it is believed that the method will yield the accurate diagnosis.

  • PDF