• Title/Summary/Keyword: earthquake safety

Search Result 887, Processing Time 0.023 seconds

Seismic Performance Assessment of Existing Circular Sectional RC Bridge Columns according to Lap-splice Length of Longitudinal Bars (축방향철근의 겹침이음길이에 따른 원형 RC교각의 내진성능평가)

  • Park, Kwang Soon;Seo, Hyeong Yeol;Kim, Tae-Hoon;Kim, Ick Hyun;Sun, Chang Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.201-212
    • /
    • 2014
  • The plastic hinge region of RC pier ensures its nonlinear behavior during strong earthquake events. It is assumed that the piers secure sufficient strength and ductility in order to prevent the collapse of the bridge during strong earthquake. However, the presence of a lap-splice of longitudinal bars in the plastic hinge region may lead to the occurrence of early bond failure in the lap-splice zone and result in significant loss of the seismic performance. The current regulations for seismic performance evaluation limit the ultimate strain and displacement ductility considering the eventual presence of lap-splice, but do not consider the lap-splice length. In this study, seismic performance test and analysis are performed according to the cross-sectional size and the lap-splice length in the case of longitudinal bars with lap-splice located in the plastic hinge region of existing RC bridge columns with circular cross-section. The seismic behavioral characteristics of the piers are also analyzed. Based upon the results, this paper presents a more reasonable seismic performance evaluation method considering the lap-splice length and the cross-sectional size of the column.

Soil-Structure Interaction Analysis for Base-Isolated Nuclear Power Plants Using an Iterative Approach (반복법을 이용한 면진적용 원전구조물의 지반-구조물 상호작용 해석)

  • Han, Seung Ryong;Nam, Min Jun;Seo, Choon Gyo;Lee, Sang Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • The nuclear accident due to the recent earthquake in Japan has triggered awareness of the importance of safety with regard to nuclear power plants (NPPs). An earthquake is one of the most important parameters which governs the safety of NPPs among external events. Application of a base isolation system for NPPs can reduce the risk for earthquakes. At present, a soil-structure interaction (SSI) analysis is essential in the seismic design of NPPs in consideration of the ground structure interaction. In the seismic analysis of the base-isolated NPP, it is restrictive to consider the nonlinear properties of seismic isolation devices due to the linear analysis of the SSI analysis programs, such as SASSI. Thus, in this study, SSI analyses are performed using an iterative approach considering the material nonlinearity of the isolators. By performing the SSI analysis using an iterative approach, the nonlinear properties of isolators can be considered. The difference between the SSI analysis results without iteration and SSI with iteration using SASSI is noticeable. The results of the SSI analysis using an effective linear (non-iterative) approach underestimate the spectral acceleration because the effective linear model cannot consider the nonlinear properties of isolators. The results of the SSI analysis show that the horizontal response of the base-isolated NPP is significantly reduced.

A Study on the Earthquake Safety Assessment of Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 지진 안전성평가에 관한 연구)

  • Ham, Eun-Gu;Lee, Sung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.226-235
    • /
    • 2021
  • Purpose: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Method: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Result: In this study, by statically loading earthquake loads and evaluating the level of collapse prevention of special-class structures, facility managers can easily recognize and evaluate the risk level, and this analysis result can be applied to future facility risk management. Earthquake analysis was performed so that. Conclusion: As a result of analyzing the Coalescer facility according to the current design standard KBC2016, the stress ratio of the main supporting members was found to be up to 4.7%. Therefore, the members supporting Coalescer were interpreted as being safe against earthquakes with a reproducibility period of 2400 years that may occur in Korea.

A Study on the Relationship between Response Spectrum and Seismic Fragility Using Single Degree of Freedom System (단자유도 해석모델을 활용한 응답스펙트럼과 지진취약도 곡선과의 관계에 대한 연구)

  • Park, Sangki;Cho, Jeong-rae;Cho, Chang-beck;Lee, JinHyuk;Kim, Dong-Chan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.245-252
    • /
    • 2023
  • In general, the design response spectrum in seismic design codes is based on the mean-plus-one-standard deviation response spectrum to secure high safety. In this study, response spectrum analysis was performed using seismic wave records adopted in domestic horizontal design spectrum development studies, while three response spectra were calculated by combining the mean and standard deviation of the spectra. Seismic wave spectral matching generated seismic wave sets matching each response spectrum. Then, seismic fragility was performed by setting three damage levels using a single-degree-of-freedom system. A correlation analysis was performed using a comparative analysis of the change in the response spectrum and the seismic fragility concerning the three response spectra. Finally, in the case of the response spectrum considering the mean and standard deviation, like the design response spectrum, the earthquake load was relatively high, indicating that conservative design or high safety can be secured.

Variations of Temperature, Chemical Component and Helium Gas of Geothermal Water by Earthquake Events in Pohang Area (포항 지열수의 지진에 의한 수온, 화학성분 및 헬륨가스의 변화)

  • Lee, Yong Cheon;Jeong, Chan Ho;Lee, Yu Jin;Kim, Young-Seog;Kang, Tae-Seob
    • The Journal of Engineering Geology
    • /
    • v.31 no.4
    • /
    • pp.647-658
    • /
    • 2021
  • In this study, the change of temperature, chemical composition, and helium gas of thermal water in Pohang area was observed from January 2018 to June 2019 in order to interpret the relationship with earthquake events. During observation period earthquakes above M 2.0 within 100 km in a radius from a geothermal well occurred 58 including two earthquake events with a magnitude of 3.0~3.9 and two earthquake events with a magnitude of 4.0~4.9. We introduce a q-factor and earthquake effectiveness (ε) to express the influence of each earthquake as magnitude and distance factors. The geothermal well of 715 m deep was developed in the Bulguksa biotite granite, and the water temperature was observed in the variation from 51.8 to 56.3℃ during monitoring period. At M 4.1 and M 4.6 earthquake events, the increase of geothermal water temperature (𝜟T 2.6~4.5℃) was recorded, and slight change in specific ionic components such as SO4 and Cl, and of chemical types on the Piper diagram were observed. In the 3He/4He vs 4He/20Ne diagram, the original mixing ratio of helium isotope before and after the magnitude 4.1 earthquake was slightly changed from 83.0% to 83.2% of crust-origin 4He, and the from 16.3% to 16.7% of mantle-origin 3He. Hot-cold water mixing ratio before and after earthquakes by using the quartz and chalcedony solubility curves of the silica-enthalpy mixing model was calculated to interpret the temperature change of geothermal water. The model calculation shows the increase of 6.93~7.72% and 1.65~4.94% of hot water ratio at E1 and E2 earthquakes, respectively. Conclusively, the magnitude of earthquake for observable change in the temperature and helium isotope of thermal water is of 4.1 or higher and q-factor value of 30.0 or higher in the study site.

Behavior of Seepage and Seismic for the Deterioration Reservoir Using Numerical Analysis (수치해석에 의한 노후저수지의 침투 및 동적거동)

  • Park, Sung-Yong;Chang, Suk-Hyun;Lim, Hyun-Taek;Kim, Jung-Meyon;Kim, Yong-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.3
    • /
    • pp.81-90
    • /
    • 2016
  • It is significant to redevelop the deterioration reservoir through raising for countermeasure to climate change and Earthquake improvement of reservoir. This study aims to investigate the behavior of deterioration reservoir with poor-fabricated core subjected to raising water level and earthquake using numerical analysis. From the analysis results, water level raising and earthquakes induce crack and subsidences at the crown and the front side of deterioration reservoir. For the reinforcement of the deterioration reservoir is required appropriate measures method and raised method suitable, drainage and slope protection method judged to be necessary.

Dynamic Behavior Analysis of Bridges under the Combined Effect of Earthquake and Scour (지진 및 기초의 세굴을 고려한 교량시스템의 동적거동분석)

  • 김상효;최성욱;이상우;김호상
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.187-194
    • /
    • 2002
  • Bridge dynamic behaviors and the failure of the foundation are examined in this study under seismic excitations including the local scour effect. The simplified mechanical model, which can consider the effect of various influence elements, is proposed to simulate the bridge motions. The scour depths around the foundations are estimated by the CSU equation recommended by the HEC-18 and the local scour effect upon global bridge motions is then considered by applying various foundation stiffness based upon the reduced embedded depths. From the simulation results, it is found that seismic responses of a bridge with the same scour depth for both foundations increase due to the local scour effect. The bridge scour is found to be significant under weak and moderate seismic intensity. The recovery durations of the foundation stiffness after local scour are found to be critical in the estimation of the probability of foundation failure under earthquakes. Therefore, the safety of the whole bridge system should be conducted with the consideration of the scour effect upon the foundations and the recovery duration of stiffness should be determined rationally.

  • PDF

Introduction of the Building Standard Law of Japan and the Performance-Based Seismic Design Methodology (일본의 내진설계법 및 내진성능 평가법의 소개)

  • 전대한;노필성
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.341-348
    • /
    • 2002
  • This manuscript introduces the Building Standard Law of Japan revised at 2000, June. Recently, The Building Standard Law of Japan was revised into the performance-based design format following the trend of international. The structural performance was evaluated for two limiting states; serviceability and soundness limit state, and safety limit state. The design earthquake forces were determined on the basis of seismic activities of the construction site, taking into consideration (a)characteristics of focal mechanism, (b)amplification by local surfaces geology, and (c)soil-structure interaction, in addition to the properties of the planned building including scale, configuration, foundation system, and structural characteristics.

  • PDF

DIRECT INELASTIC EARTHQUAKE DESIGN OF R/C STRUCTURE

  • Park, Hong-Gun;Eom, Tae-Sung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.472-477
    • /
    • 2004
  • A new earthquake design method performing iterative calculations with secant stiffness was developed. Since basically the proposed design method uses linear analysis, it is convenient and stable in numerical analysis. At the same time, the proposed design method can accurately estimate the inelastic strength and ductility demands of the structural members through iterative calculations. In the present study, the procedure of the proposed design method was established, and a computer program incorporating the proposed method was developed. The proposed method, as an integrated analysis and design method, can directly address the earthquake design strategy intended by the engineer, such as limited ductility of member and the concept of strong column - weak beam. Through iterative calculations on a structural model with member sizes preliminarily assumed, the strength and ductility demands of each member can be determined so as to satisfy the given design strategy. As the result, structural safety and economical design can be achieved.

  • PDF

Evaluation of Post-earthquake Seismic Capacity of Reinforced Concrete Buildings suffering from earthquakes (지진피해를 받은 철근콘크리트 건물의 잔존내진성능평가)

  • Kang, Dae-Eon;Yi, Waon-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.105-108
    • /
    • 2005
  • In damage investigation of building structures suffering from earthquake, estimation of residual seismic capacity is essential in order to access the safety of the building against aftershocks and to judge the necessity of repair and restoration. It has been proposed that an evaluation method for post-earthquake seismic capacity of reinforced concrete buildings based. on the residual energy dissipation capacity (the residual seismic capacity ratio )in lateral force-displacement curve of structural members. The proposed method was adopted in the Japanese 'Damage Level Classification Standard' revised in 200l. To evaluate the residual seismic capacity of RC column, experimental tests with positive and negative cyclic loading was carried out using RC building column specimen. Parameters used by the experiment are deformability and member proportion. From the test results, it is appropriated that the residual seismic capacity of RC buildings damaged by earthquakes is evaluated using the method in the Guideline.

  • PDF