• Title/Summary/Keyword: earthquake motion

Search Result 926, Processing Time 0.023 seconds

Noise Effects on Shaking Table Test of Structures (진동대를 이용한 구조물의 내진실험시 잡음의 영향에 관한 고찰)

  • 최인길
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.312-319
    • /
    • 1998
  • The effect of noise on the input motion for the seismic test of structures using shaking table was studied. Table motions usually contain high frequency contents which influence the PGA of input motions. It was shown that the noise influenced PGA much with minor changes in high frequency contents. The Butterworth bandpass filter can be effectively used. The adequacy of the table motion should be judged based on both the frequency contents and the PGA.

  • PDF

Progress in Seismic Design Concept in Moderate Seismicity regions (중약진 지역에서의 내진설계 개념의 발전동향)

  • 장승필
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.217-222
    • /
    • 1999
  • Seismic design in low to moderate seismic regions has to be based on the characteristics of seismic risk ground motion and structural response in that region. The characteristics of seismic hazard in low to moderate seismic regions are reviewed briefly. The recent findings on the dynamic behavior subjected to the moderate intensity level of ground motion are summarized. The seismic design considerations in Easterm America China Australia Thailand and Hong Kong will be introduced, . The effort to adopt the limited ductility design in low to moderate seismicity regions will be reported. Finally research works that are required for the implementation of the limited design concept will be proposed.

  • PDF

Method of the Calibration of earthquake Ground Motions for Seismic Design (내진설계를 위한 지진 입력하중 조정 방법)

  • 공도환
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.20-27
    • /
    • 1998
  • In the current seismic design codes design earthquake is usually defined as the earthquake with the 90 percent probability of not being exceeded in the life time of a structure which is assumed as 50 years equivalent to the earthquake with 475 year recurrence period. However the life time of tall building structures may be much longer than 50 yers. The current seismic design code requires the modal analysis or dynamic time history analysis for the buildings with the height exceeding a certain height limit. The objective of this study is to collect the earthquake ground motion(EQGM) which can be used for dynamic time history analysis for tall buildings. For this purpose linear elastic design response spectrum (LEDRS) in the code is scaled to account for the recurrence period of the design earthquake. The earthquake ground motions which has been recorded are calibrated to fit the scaled LEDRS. The set of calibrated EQGM can be treated as design EQGM for the design of tall building with longer lifetime than ordinary building.

  • PDF

Dynamic Deformation Characteristics of Korean Hydraulic-Fills Soil Deposits (국내 준설매립토 지반의 동적변형특성)

  • 김동수
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.69-76
    • /
    • 1999
  • Because of the limited land in Korea most of the projects require large-scale reclamation. The hydraulic-filled soil deposits are usually loose and susceptible to be liquified during earthquake. The dynamic deformation characteristics which expressed by shear modulus and damping ratio are important to analyze the earthquake ground motion. In this paper resonant column tests were performed on five hydraulic filled soil in Korea and the deformational characteristics at both small and medium strains were investigated. The coefficients in the Hardin equation to predict the representative maximum shear modulus and modulus reduction cure are also proposed.

  • PDF

The Earthquake Response Characteristics and Seismic Safety Evaluation of Steel Cable Stayed Bridges (강사장교의 지진응답특성 및 내진 안전성 평가)

  • Han, Sung Ho;Shin, Jae Chul;Choi, Jin Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.5
    • /
    • pp.435-454
    • /
    • 2007
  • In this study, we demonstrated the characteristics of the near-fault ground motion thatwas not considered in the domestic seismic design code and how the effect of the near-fault ground motion affects the response of cable-stayed bridges. Afterselecting the actual measurement records of the typical near- and far-fault ground motion, the characteristics of ground motion is analyzed using the elastic and inelastic response spectrum. Analyzing the response regarding the earthquake's characteristics on cable-stayed bridges by the typical three-type cable-stayed bridges and the actual cable-stayed bridge, the characteristics of responses about main members are compared and analyzed. Moreover,reliability analysis is accomplished using the results of the seismic response analysis, and the seismic safety of the cable-stayed bridges is evaluated quantitatively as a reliability index and probability of failure. According to the results of the response spectrum, the earthquake response analysis and the reliability analysis, because the effect of the near fault ground motion against the response of cable-stayed bridges is different from the effect of the existing far-fault ground motion, it should be considered as an important factor when designing cable-stayed bridges.

A Study on Review-Level Ground Motion For Seismic Margin Assessment (내진여유도 평가를 위한 부석기준지진동(RLGM) 평가 연구)

  • 연관희;이종림
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.97-104
    • /
    • 2000
  • Evaluating a Review-Level Ground Motion is a key to efficiently perform Seismic Margin Assessment of nuclear power plants whose purpose is to determine a ground motion level for which a plant has high-confidence-of-a-low-probability of seismic-induced core damage and to identify any weaker-link components. In this study a method to obtain RLGMs is reviewed which is recommended by Electric Power Research Institute and implemented to be applied to Limerick site in eastern and central U. S as a case study. This method provides reasonable and site-specific RLGMs as minimum required plant HCLPF for SMA that meet a target mean seismic core-damage frequency based on seismic hazard results and generic values of uncertainty and randomness parameters of the core-damage fragility curves. In addition high-frequency RLGM is justifiably modified to reflect the increased seismic capacity of high-frequency components and spatial variation and incoherence of input ground motion on a basemat of large structures by establishing a method to obtain high0-frequency reduction factors according to EPRI guidelines.

  • PDF

Assessment of Code-specified Ground Motion Selection Criteria with Accurate Selection and Scaling Methods - I Ground Motion Selection (구조물 동적해석을 위한 현행 내진설계기준의 입력 지반 운동 선정 조건 타당성 평가 - I 선정방법)

  • Ha, Seong Jin;Han, Sang Whan;Ji, Hyun Woo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.171-179
    • /
    • 2017
  • For estimating the seismic demand of buildings, most seismic design provisions permit conducting linear and nonlinear response history analysis. In order to obtain reliable results from response history analyses, a proper selection of input ground motions is required. In this study, an accurate algorithm for selecting and scaling ground motions is proposed, which satisfies the ASCE 7-10 criteria. In the proposed algorithm, a desired number of ground motions are sequentially scaled and selected from a ground motion library without iterations.

Critical earthquake input energy to connected building structures using impulse input

  • Fukumoto, Yoshiyuki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • v.9 no.6
    • /
    • pp.1133-1152
    • /
    • 2015
  • A frequency-domain method is developed for evaluating the earthquake input energy to two building structures connected by viscous dampers. It is shown that the earthquake input energies to respective building structures and viscous connecting dampers can be defined as works done by the boundary forces between the subsystems on their corresponding displacements. It is demonstrated that the proposed energy transfer function is very useful for clear understanding of dependence of energy consumption ratios in respective buildings and connecting viscous dampers on their properties. It can be shown that the area of the energy transfer function for the total system is constant regardless of natural period and damping ratio because the constant Fourier amplitude of the input acceleration, relating directly the area of the energy transfer function to the input energy, indicates the Dirac delta function and only an initial velocity (kinetic energy) is given in this case. Owing to the constant area property of the energy transfer functions, the total input energy to the overall system including both buildings and connecting viscous dampers is approximately constant regardless of the quantity of connecting viscous dampers. This property leads to an advantageous feature that, if the energy consumption in the connecting viscous dampers increases, the input energies to the buildings can be reduced drastically. For the worst case analysis, critical excitation problems with respect to the impulse interval for double impulse (simplification of pulse-type impulsive ground motion) and multiple impulses (simplification of long-duration ground motion) are considered and their solutions are provided.

Design of Real-Time Ground Motion Monitoring System using MMA data (MMA 데이터를 이용한 실시간 지진동 감시 시스템 설계)

  • Lim, In-Seub;Song, Myung-Won;Jung, Soon-Key
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.29-37
    • /
    • 2007
  • In this paper, we propose a new real-time ground motion monitoring system using MMA data which can be gathered more earlier than generic seismic data transmission method. Proposed system receives maximum, minimum and average data based on 20sps which is sent from station on every second continuously. And it calculates a PGA as a quantity of ground motion then visualizes that data to monitor the ground motion around whole country. To verify PGA data from MMA data, we checked Mu-dan-jang earthquake data of China on 2002/6/29. The proposed system was inspected by using log file of Oh-dae-san earthquake data on 2007/1/20. As results of experiment, the proposed system is proven to detect the event(earthquake) faster then existing method and to produce a useful quantitative information.

  • PDF

Seismic Response Amplification Factors of Nuclear Power Plants for Seismic Performance Evaluation of Structures and Equipment due to High-frequency Earthquakes (구조물 및 기기의 내진성능 평가를 위한 고주파수 지진에 의한 원자력발전소의 지진응답 증폭계수)

  • Eem, Seung-Hyun;Choi, In-Kil;Jeon, Bub-Gyu;Kwag, Shinyoung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.123-128
    • /
    • 2020
  • Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.